{"product_id":"vibro-meter-iqs900-204-900-000-011-signal-conditioner","title":"Conditionneur de signal VIBRO-METER IQS900 204-900-000-011","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900 204-900-000-011 (IQS900)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an advanced, high-performance signal conditioner from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproduct line. It serves as the successor to the industry-standard IQS450, offering enhanced stability and diagnostics for proximity measurement chains. This unit is designed to interface with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTQ9xx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTQ4xx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducers, converting the eddy-current probe's impedance variations into a linear voltage or current signal. Integrated into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibroSmart\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for monitoring relative vibration and axial shaft position in high-speed turbines and compressors, providing the critical data needed to reduce downtime and prevent mechanical failure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e204-900-000-011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration represents the high-precision \"Standard\" version of the IQS900, optimized for modern\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Turbine Supervisory Instrumentation)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile optimized for the TQ9x2 series, it maintains backward compatibility with legacy TQ4x2 transducers, allowing for seamless site upgrades without replacing existing probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike legacy conditioners, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures improved \"Sensor OK\" monitoring, which can detect a wider range of faults including cable degradation and connector issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Temperature Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes advanced Swiss-engineered circuitry to maintain measurement linearity across extreme temperature gradients (up to 85 deg C for the conditioner itself), ensuring vibration readings remain accurate in non-climate-controlled environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a high-resolution analog output (typically voltage or current) that is directly proportional to the physical gap between the sensor tip and the target material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIQS900 204-900-000-011\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSwitzerland\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC to 20 kHz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm or 4 mm (Probe dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-18 to -30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAluminum (with 35 mm DIN rail clip)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP 20 (Standard housing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Cert\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, cCSAus (Intrinsic Safety)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the IQS900 204-900-000-011 differ from the legacy IQS450?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers a significantly lower noise floor and improved frequency response. It is also designed to meet modern cybersecurity and functional safety standards (SIL 2) when integrated into a complete\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety chain, making it more suitable for current safety-critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the correct Gap Voltage for a 2 mm system using the IQS900?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor a standard 2 mm range, the center of the linear region is typically gapped to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10 VDC\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutput range usually swings from -2 VDC (near gap) to -18 VDC (far gap).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IQS900 be used with extension cables of any length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900 204-900-000-011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be matched to a specific Total System Length (TSL), such as 1 m, 5 m, or 10 m. Using an extension cable that does not match the conditioner’s internal calibration will result in significant measurement errors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTSL (Total System Length) Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore installation, confirm that the sum of the transducer's integral cable and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEA902\/EA402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eextension cable exactly matches the TSL specified on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elabel. Misaligned lengths are the primary cause of non-linear measurement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMount the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon a standard 35 mm DIN rail. To ensure RFI\/EMI protection, the DIN rail must be connected to a clean instrument ground. If the conditioner is installed in a high-vibration area, use the optional vibration-damping mounting plate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen used in hazardous areas, ensure the use of appropriate safety barriers or galvanic separation units (like the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI127\u003c\/strong\u003e). The field wiring must follow strict Ex i (Intrinsic Safety) separation guidelines to maintain certification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIQS900 204-900-000-011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis preferred for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExceptional Long-Term Stability\u003c\/strong\u003e. In nuclear and thermal power plants where maintenance cycles can span years, the IQS900’s low aging rate for internal components ensures that the gapping remains stable without the need for frequent recalibration. Furthermore, its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFast Startup Time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the machinery protection system to be fully operational within seconds of power application, providing protection during the critical first moments of turbine startup.\u003c\/p\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695206068587,"sku":"IQS900 204-900-000-011","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-iqs900-204-900-000-011-signal-conditioner-govecgon3ur_f5005dad-f091-432c-951c-a1901e5ac695.jpg?v=1766130690","url":"https:\/\/www.plcprotech.com\/fr\/products\/vibro-meter-iqs900-204-900-000-011-signal-conditioner","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}