{"product_id":"vibro-meter-vm600-abe042-204-042-100-011-system-rack","title":"Rack système Vibro-Meter VM600 ABE042 204-042-100-011","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVM600 ABE042 204-042-100-011\u003c\/strong\u003e is a robust, 19-inch industrial system rack from Parker Meggitt's \u003cstrong\u003evibro-meter®\u003c\/strong\u003e product line. Standing at a standard height of 6U , this unit is specifically designed to house high-performance hardware modules for the \u003cstrong\u003eVM600\u003c\/strong\u003e and \u003cstrong\u003eVM600Mk2\u003c\/strong\u003e series machinery protection and condition monitoring systems. Constructed from high-grade extruded aluminum , it provides an exceptionally stable, electrically clean , and structurally secure environment for permanent cabinet or panel installation within harsh industrial settings.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Built with an extruded aluminum frame paired with solid aluminum structural components to tolerate severe industrial stressors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated VME Backplane:\u003c\/strong\u003e Features an integrated multi-bus backplane that handles all internal electrical routing, including power distribution and data sharing via the VME bus, Tacho bus, Raw bus, and Open Collector (OC) bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Versatility:\u003c\/strong\u003e The rack provides up to 15 standard front card positions , allowing flexible mixed configurations of protection, condition monitoring, and CPU modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Power Management:\u003c\/strong\u003e Built-in support for up to two RPS6U power supplies alongside an integrated rear power supply check relay to actively monitor system health.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear-Bracket Design:\u003c\/strong\u003e The \u003cstrong\u003eABE042\u003c\/strong\u003e variant differs uniquely from the ABE040 model by placing its heavy-duty mounting brackets exclusively at the rear of the unit , adapting to deep or specialized panel requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWind Power Generation:\u003c\/strong\u003e Monitoring structural dynamics and drivetrain health inside large wind turbine nacelles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; Gas Offshore Platforms:\u003c\/strong\u003e Serving as the structural heart for vibration diagnostic arrays on critical offshore injection and output pump sets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy Industrial Processing:\u003c\/strong\u003e Continuous machinery protection for main gearboxes and heavy-duty motors in steel mills, paper factories, and mining facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Vent and Blast Fan Arrays:\u003c\/strong\u003e Tracking continuous operational trends for essential kiln blowers and furnace ventilation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Architecture \u0026amp; Slot Layout\u003c\/h3\u003e\n\u003cp\u003eThe rack implements a strict front-to-back dual-card architecture. Processing modules slide into the front slots , plugging directly into the backplane, while their matching input\/output (I\/O) connectors interface from the rear:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Slots (Up to 15 Card Capacity):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots 00 to 01:\u003c\/strong\u003e Dedicated to system rack controllers and communications interfaces (e.g., $CPUM^{Mk2}$ or CPUx module pairs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot 02:\u003c\/strong\u003e Reserved exclusively for specialized or application-specific hardware modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots 03 to 14:\u003c\/strong\u003e Allocated for advanced processing modules such as the MPC4\/MPC4Mk2 machinery protection cards or XMx16 condition monitoring cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Slots:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots 00 to 18:\u003c\/strong\u003e Accepts high-density interface cards (e.g., IOC4T, IOC4Mk2, XIO16T, IOC8T) or programmable relay outputs (e.g., RLC16Mk2, IRC4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots 15 to 20:\u003c\/strong\u003e Allocated for mounting power supply inputs and managing redundant lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVibro-Meter (Parker Meggitt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003evibro-meter®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM600 ABE042 204-042-100-011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number (PNR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e204-042-100-011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch System Rack (6U Height)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtruded aluminum frame with solid aluminum parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGuide Strip Inserts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop\/bottom low-friction plastic card guides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuses Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVME bus, Tacho bus, Raw signal bus, Open Collector (OC) bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVM600 \/ VM600Mk2 RPS6U Rack Power Supply (330W versions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Check Relay Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax switching: 30 VRMs\/I42.4 VAC(PEAK) or 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCheck Relay Maximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4AAc or3 ADc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70 Celsius (32 to 158 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 Celsius (-40 to 185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 55 Hz, 0.35 mm peak, 6 hours per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 g peak, 11 ms duration, half-sine pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limitation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLimited strictly to clean indoor use (requires enclosure if outdoors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Structural Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~6.5 kg (~14.3 lbs) \u003ci\u003e(unpopulated, without cards or power supplies)\u003c\/i\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEstimated Package Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48.6 x 32.5 x 26.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Securely mount using the integrated rear brackets within standard 19-inch electrical racks or console panels. Ensure adequate vertical clearance for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety Grounding:\u003c\/strong\u003e The main aluminum frame must be permanently bonded to local Protective Earth (PE) to establish zero-signal reference stability and mitigate electrical shock hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Blanking:\u003c\/strong\u003e For thermal regulation, safety boundaries, and electromagnetic compatibility (EMC), any unpopulated front or rear slot position must be enclosed using original blank panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Redundancy Setup:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle RPS6U Operation:\u003c\/strong\u003e A single 330W power module running in slot positions 18 to 20 fully drives a maximum rack complement at temperatures up to 50 Celsius. The adjacent unused power bay (slots 15 to 17) must be blanked off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual RPS6U Redundant Operation:\u003c\/strong\u003e Installing two power modules establishes a true redundant config. If primary module unit PS1 encounters a fault, the secondary unit PS2 dynamically inherits 100% load without system down-time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Operation:\u003c\/strong\u003e Operating above 50 Celsius requires two RPS6U modules running concurrently in a non-redundant state to meet structural output power de-rating requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Isolation (GSI Barriers):\u003c\/strong\u003e External galvanic separation units (such as GSI127 series barriers) cannot derive power from the VME backplane rail. They must be anchored externally in a dedicated remote housing box or neighboring auxiliary enclosure with its own standalone power rail.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Regulatory Approvals\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformity Markings:\u003c\/strong\u003e Fully compliant with European Union (CE Marking) and Eurasian Customs Union (EAC) declarations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certifications:\u003c\/strong\u003e Certified to cCSAus standards for industrial equipment safety, and fully compliant with IEC\/EN 61010-1 electrical guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Engineered to meet strict industrial immunity and emission criteria under IEC\/EN 61000-6-2 and IEC\/EN 61000-6-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Management:\u003c\/strong\u003e Fully compliant with global RoHS directive restrictions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":53240087347563,"sku":"VM600 ABE042 204-042-100-011","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ABE042204-042-100-011.png?v=1779885656","url":"https:\/\/www.plcprotech.com\/fr\/products\/vibro-meter-vm600-abe042-204-042-100-011-system-rack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}