{"product_id":"x20ai2622-b-r-x20-analog-input-module-high-precision-dual-channel","title":"Module d'entrée analogique haute précision double canal B\u0026R X20AI2622 X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI2622 (X20AI2622)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R X20 System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elineup, engineered for precision signal acquisition in sophisticated automation environments. Equipped with two individually configurable inputs, this module provides the flexibility to interface with standard industrial signals, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±10 V voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 to 20 mA \/ 4 to 20 mA current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eloops. Whether monitoring pressure in hydraulic systems, temperature in chemical reactors, or flow rates in water treatment plants, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI2622\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esets a new standard for accuracy and reliability, ensuring that critical process data is digitized with minimal noise and maximum fidelity.\u003c\/p\u003e\n\u003ch3\u003eSignal Processing \u0026amp; Diagnostic Intelligence\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI2622\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for low power consumption and high thermal stability, consuming only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.01 W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the bus and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.8 W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor internal I\/O operations. This efficiency prevents heat buildup in high-density control cabinets, thereby extending the lifespan of the entire I\/O station.\u003c\/p\u003e\n\u003cp\u003eThe module features a comprehensive set of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estatus indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat provide real-time feedback on the operating state, module status, and individual I\/O function per channel. This localized diagnostic capability allows field technicians to identify signal loss or hardware faults at a glance, significantly reducing maintenance overhead. The inputs are designed for high-resolution conversion, enabling the detection of minute fluctuations in field signals which is essential for high-end PID control loops and predictive analytics.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eX20AI2622\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Range (Voltage)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Range (Current)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption (Bus)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption (Internal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED indicators for status and I\/O function\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between voltage and current modes on the X20AI2622?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe input mode is determined via software configuration in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB\u0026amp;R Automation Studio\u003c\/strong\u003e. There are no physical jumpers on the module, which eliminates the risk of hardware configuration errors during installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support wire-break detection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when configured for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erange, the module can detect a wire break if the signal drops below the standard threshold, triggering a diagnostic bit in the CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"I\/O function per channel\" LED?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach input channel has a dedicated LED that indicates the validity of the incoming signal. This allows for rapid physical verification of the field wiring without needing to connect a laptop to the controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImpedance Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the current input (0-20 mA), ensure that the total loop resistance of the connected sensor does not exceed the module's maximum input impedance. This maintains signal linearity and prevents clipping at the upper end of the range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog signals are highly susceptible to high-frequency noise. Always use shielded, twisted-pair cables. The shield should be grounded using the X20 system's grounding plate to provide a low-resistance path for electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI2622\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas a very low power profile (\u003cstrong\u003e0.8 W\u003c\/strong\u003e), it is best practice to group analog modules away from high-heat digital output modules (like relays) to ensure the reference voltage remains stable over the long term.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20AI2622\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers a significant engineering advantage through its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-mode versatility\u003c\/strong\u003e. By supporting both voltage and current inputs on a single module, it reduces the variety of spare parts a facility needs to stock. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efanless and ruggedized\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eX20 housing ensures long-term performance in environments characterized by mechanical vibration and temperature fluctuations. Furthermore, the integration with the X2X Link ensures deterministic data transmission, making it ideal for high-speed industrial applications where timing and precision are non-negotiable.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086379409771,"sku":"X20AI2622","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ai2622-mzbspnxokcx.png?v=1776064745","url":"https:\/\/www.plcprotech.com\/fr\/products\/x20ai2622-b-r-x20-analog-input-module-high-precision-dual-channel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}