{"product_id":"x20bm32-b-r-x20-series-backplane-bus-module","title":"Module de bus de fond de panier série X20BM32 B\u0026R X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BM32 (X20BM32)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a fundamental backplane component of the B\u0026amp;R X20 System, serving as the mechanical and electrical foundation for I\/O modules. This bus module facilitates the seamless distribution of both internal K-bus communication and the 24 VDC I\/O power supply across the terminal rail. By providing a rugged interface for the X20 electronics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BM32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables hot-swappable modularity, allowing engineers to replace electronic modules without disturbing the permanent field wiring. Engineered for high-availability environments such as automotive assembly and renewable energy management, it supports a high contact load of 10 A, ensuring sufficient power distribution for multiple downstream digital or analog modules in a single segment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BM32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for maximum mounting flexibility, supporting both horizontal and vertical installation orientations without compromising electrical integrity. It features a passive internal bus structure with a negligible power consumption of only 0.13 W, ensuring that the bulk of the system's power is reserved for logic processing and field actuators. The module's design incorporates a specialized 24 VDC power bus with a permissible contact load of 10 A, which is essential for high-density I\/O configurations. Furthermore, the unit is engineered for global deployment, featuring specific thermal derating guidelines for high-altitude installations above 2000 meters to ensure long-term reliability in varying atmospheric conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20BM32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBus Module (Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.13 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Nominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Contact Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal or Vertical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Elevation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 2000 m (No limitation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHigh Altitude Derating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-0.5 Celsius per 100 m (Above 2000 m)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05 kg (Net)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the X20BM32 provide the electrical termination for the X20 bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The X20BM32 is a through-bus module that facilitates communication between modules. The termination of the X20 bus is typically handled by the Bus Controller or the specialized X20PS (Power Supply) and X20BT (Bus Termination) modules depending on the network topology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an I\/O module while the X20BM32 is still powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. One of the primary advantages of the X20BM32 is that it allows for \"hot-swapping\" of the electronic I\/O modules. Because the field wiring is attached to the terminal block on the bus module, the electronic slice can be removed and replaced without disconnecting wires or powering down the entire station.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is there a temperature reduction requirement for high-altitude use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt altitudes above 2000 meters, the air density decreases, which reduces the efficiency of convective cooling. To prevent internal hotspots on the 10 A power bus, the ambient operating temperature must be reduced by 0.5 Celsius for every 100 meters of elevation gained.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BM32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the DIN rail, ensure that the side locking levers are fully engaged with the adjacent bus module. A gap as small as 0.5 mm can lead to intermittent K-bus communication errors or high resistance on the 10 A power contacts, potentially causing system resets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Segment Planning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince the module is rated for a 10 A contact load, always calculate the total current draw of all I\/O modules in the segment. If the cumulative load exceeds 10 A, you must insert an X20PS (Power Supply) module to start a new power segment and prevent overloading the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BM32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einternal bus bars.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module is rated IP20, it should always be installed in a clean, dry control cabinet. In environments with conductive dust or high humidity, ensure the cabinet is sealed and filtered, as the exposed bus contacts on the side of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20BM32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare sensitive to contamination that can cause short circuits between the 24 VDC and K-bus lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53102123581803,"sku":"X20BM32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20bm32-gmaxrnbksks.png?v=1776138146","url":"https:\/\/www.plcprotech.com\/fr\/products\/x20bm32-b-r-x20-series-backplane-bus-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}