{"product_id":"x20cp0484-b-r-x20-compact-s-controller-plc-module","title":"Module automate Compact-S B\u0026R X20CP0484 X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP0484 (X20CP0484)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance entry-level controller within the B\u0026amp;R X20 Compact-S series, delivering significant processing power in an extremely space-efficient form factor. Equipped with a 500 MHz clock frequency, this PLC is engineered for decentralized automation tasks and mid-range machine control where cabinet real estate is at a premium. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20CP0484\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a versatile system module, integrating multiple communication interfaces including Ethernet and POWERLINK V2 to ensure seamless deterministic networking. In applications such as specialized packaging machinery, modular conveyor systems, and building automation, this controller provides the necessary computational speed to manage complex logic and synchronized motion while maintaining a low power consumption profile of only 2.95 W.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe X20CP0484 architecture is designed for connectivity and expansion. It features a dedicated POWERLINK V2 interface for real-time, jitter-free communication with drives and I\/O stations, alongside a standard Ethernet port for high-level factory network integration. The inclusion of two USB ports allows for easy firmware updates, data logging, and peripheral connection. For local expansion, the integrated X2X Link interface enables the direct connection of X20 I\/O modules, allowing the controller to scale with the application requirements. Operating with a 500 MHz processor, the module balances execution speed with thermal efficiency. The hardware is designed as a standalone system module that manages the entire X20 backplane, providing the clock and synchronization signals necessary for precision industrial control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20CP0484\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R (Bernecker + Rainer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 Compact-S PLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eClock Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x 10\/100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal-Time Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x POWERLINK V2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUSB Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x USB 2.0 Type A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExpansion Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x X2X Link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.95 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Module\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eController\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the X20CP0484 support data persistence during power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the controller supports non-volatile memory for remanent variables. This ensures that critical machine states, counters, and recipe data are retained even during an unscheduled power interruption, allowing for a faster and safer recovery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many X20 I\/O modules can be directly managed by the X20CP0484?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe local X2X Link can typically support up to 253 modules, though the actual limit is determined by the total power consumption on the backplane and the processing requirements of the specific application logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software environment is required to program this PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe X20CP0484 is programmed and configured using B\u0026amp;R Automation Studio. This single-tool environment handles everything from logic programming in IEC 61131-3 languages to hardware configuration and network diagnostics.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation and Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 2.95 W power consumption is low, the X20CP0484 should be mounted vertically on a standard DIN rail to utilize natural convection. Ensure a minimum clearance of 20 mm above and below the unit to prevent heat buildup, which could affect the internal processor clock stability over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUSB Port Usage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual USB ports are intended for maintenance and peripheral connection. When using USB flash drives for data logging, industrial-grade SLC flash memory is recommended to withstand the vibration and temperature fluctuations common in industrial cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOWERLINK Network Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure deterministic communication at the 500 MHz processing level, always use shielded Category 5e (or higher) cables for the POWERLINK and Ethernet connections. The shield should be grounded through the RJ45 connector to the controller's metal chassis to mitigate EMI from nearby variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086377607531,"sku":"X20CP0484","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20cp0484-vwsyzmbkqam.png?v=1776138158","url":"https:\/\/www.plcprotech.com\/fr\/products\/x20cp0484-b-r-x20-compact-s-controller-plc-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}