{"product_id":"x20sp1130-b-r-x20-system-safe-power-supply-module","title":"Module d'alimentation sécurisée système X20SP1130 B\u0026R X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20SP1130 (X20SP1130)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance safety power supply module from the B\u0026amp;R X20 System, specifically designed for safety-critical industrial applications. This module provides a single safe Type B1 digital output with a substantial 10 A nominal current capacity at 24 VDC. Engineered for use in functional safety circuits, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eX20SP1130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a reliable power source for safe I\/O groups, allowing for the controlled and safe disconnection of potential groups within the X20 rack. Its Field Effect Transistor (FET) design features dual positive switching, ensuring a high level of diagnostic coverage and fault tolerance. By enabling the output level to be readable by the system, it provides engineers with real-time feedback for sophisticated safety monitoring and diagnostic routines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe X20SP1130 is characterized by its \"Type B1\" safe output architecture, which operates without OSSD (Output Signal Switching Device) signals, making it ideal for specific safety potential group configurations. The module utilizes a dual positive switching FET variant, which provides redundant paths for power interruption, a fundamental requirement for high-level safety performance. A critical integration note for this module is the requirement to verify the list of permitted modules within the potential group it supplies; this ensures that all downstream components are compatible with the safe disconnection logic. The hardware is designed for industrial durability, maintaining a wide humidity tolerance of 5% to 95% across operation, storage, and transport phases.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20SP1130\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafe Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType B1 (Digital Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSwitching Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFET, 2x Positive Switching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Feedback\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Level Readable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eX20 Terminal Block \/ Bus Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.125 kg (Approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Type B1\" designation for this safe output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType B1 refers to a specific safety characteristic in B\u0026amp;R systems where the output is intended for the safe supply of potential groups. It indicates that the module can safely shut down power to a group of standard or safety modules, provided they are on the permitted compatibility list.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the \"Output level readable\" feature important in a safety module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis feature allows the safety controller to verify the actual state of the 10 A output against the commanded state. This diagnostic feedback is essential for detecting cross-circuits, external voltage feed-ins, or internal hardware failures, thereby increasing the overall Safety Integrity Level (SIL).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, like all X20 modules, the X20SP1130 must be used with the appropriate X20 terminal block and bus module. The high 10 A current rating requires that the wiring and terminal block are correctly rated to handle the thermal load during continuous operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePotential Group Planning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen designing the safety circuit, refer to the official B\u0026amp;R \"List of Permitted Modules\" for the X20SP1130. Only compatible modules should be placed to the right of the SP1130 in the potential group to ensure that the safe shutdown signal is correctly propagated and that no unsafe modules compromise the safety function.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 10 A nominal output, the X20SP1130 can generate localized heat. Ensure the X20 rack has adequate ventilation. When multiple high-power modules are installed side-by-side, it is best practice to calculate the total power dissipation and ensure the cabinet ambient temperature does not exceed the operating limits (typically 55 deg C to 60 deg C for X20 systems).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse 2.5 mm² (14 AWG) or larger wire for the 24 VDC supply and safe output connections to minimize voltage drop and prevent terminal overheating. Given the lack of OSSD, ensure that the external safety logic and feedback loops are correctly configured in the B\u0026amp;R SafeDESIGNER environment to maintain the intended safety category (e.g., PL e \/ SIL 3).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53102131282283,"sku":"X20SP1130","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20sp1130-bs00zrltgva.png?v=1776138229","url":"https:\/\/www.plcprotech.com\/fr\/products\/x20sp1130-b-r-x20-system-safe-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}