{"product_id":"x67ps1300-b-r-x67-system-power-supply-module","title":"Module d'alimentation système X67PS1300 B\u0026R X67","description":"\u003ch3 data-path-to-node=\"1\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe \u003cb data-path-to-node=\"2\" data-index-in-node=\"4\"\u003eX67PS1300 (X67PS1300)\u003c\/b\u003e is a high-performance power supply module from B\u0026amp;R Industrial Automation’s X67 system, designed specifically to provide an electrically isolated power source for the X2X Link bus. This module is a critical infrastructure component for decentralized I\/O architectures, ensuring that the communication link remains stable and protected from potential ground loops or electrical interference originating from the field side. The \u003cb data-path-to-node=\"2\" data-index-in-node=\"452\"\u003eX67PS1300\u003c\/b\u003e features integrated diagnostics through clear status indicators for both input and output voltage levels, allowing maintenance personnel to quickly verify power health at a glance. Its compact, rugged design makes it ideal for direct machine mounting in harsh industrial environments where space is limited and reliability is paramount.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe X67PS1300 is engineered for seamless integration into the B\u0026amp;R X67 I\/O system. It functions by decoupling the internal system supply from the incoming field power, providing a clean and isolated 24 VDC supply to the X2X Link. This isolation is vital for maintaining signal integrity over long distances and across multiple remote I\/O nodes. The module’s hardware includes two status LEDs: one indicating that the \"Input voltage\" is within the tolerance range, and another confirming the \"Output voltage\" is active and ready. With a very low internal power consumption of only 3 W, the module operates efficiently with minimal heat generation, which is essential for high-density DIN rail or panel installations.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"6\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,1,0\"\u003eX67PS1300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,1,0\"\u003eB\u0026amp;R Industrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,3,0,0\"\u003eProduct Group\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,3,1,0\"\u003eX67 System \/ X2X Link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,0,0\"\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,1,0\"\u003eElectrically Isolated Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,5,0,0\"\u003eStatus Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,5,1,0\"\u003eInput Voltage OK, Output Voltage OK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,6,0,0\"\u003eInternal Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,6,1,0\"\u003e3 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,7,0,0\"\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,7,1,0\"\u003e24 VDC (-15% \/ +20%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,8,0,0\"\u003eWidth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,8,1,0\"\u003e5.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,0,0\"\u003eHeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,1,0\"\u003e8.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,10,0,0\"\u003eDepth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,10,1,0\"\u003e4.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,11,0,0\"\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,11,1,0\"\u003e0.225 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,12,0,0\"\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,12,1,0\"\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eWhen is it necessary to add an X67PS1300 to an X67 I\/O segment?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eAn additional power supply module is required when the total power consumption of the connected X67 modules exceeds the current capacity provided by the bus controller, or when electrical isolation is needed to segment the bus for noise reduction.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eCan this module power 24 VDC sensors and actuators directly?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eNo, the X67PS1300 is specifically designed to provide isolated power for the \u003cb data-path-to-node=\"9\" data-index-in-node=\"138\"\u003eX2X Link communication bus\u003c\/b\u003e. Field devices (sensors\/actuators) should be powered via the standard I\/O module power pins or a dedicated field power supply.\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eWhat does it mean if the \"Output voltage OK\" LED is off but the \"Input\" LED is on?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eThis indicates an internal fault or an overload\/short circuit on the X2X Link side. Disconnect the downstream X2X bus cables and check for shorts or excessive current draw from the connected I\/O modules.\u003c\/p\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eX2X Link Grounding and Shielding:\u003c\/b\u003e To ensure maximum interference immunity, the X2X Link cable must be properly shielded. When installing the \u003cb data-path-to-node=\"13\" data-index-in-node=\"141\"\u003eX67PS1300\u003c\/b\u003e, ensure that the shield is connected to the functional ground (FE) at the module's mounting point. The electrical isolation provided by the PS1300 will prevent ground loops between different machine sections.\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eThermal Considerations:\u003c\/b\u003e Although the internal power consumption is low (3 W), B\u0026amp;R recommends installing the module vertically to facilitate natural convection. Avoid placing high-heat-generating components (like motor starters or large power supplies) directly beneath the X67PS1300 to prevent thermal stress on the diagnostic electronics.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eSafe Termination:\u003c\/b\u003e Before connecting or disconnecting the X2X Link cables to the X67PS1300, always ensure the input power is switched off. Plugging the module into an active \"hot\" bus can cause communication transients that may disrupt the synchronization of the PLC cycle or cause temporary bus errors in the X67 network.\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53102131544427,"sku":"X67PS1300","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x67ps1300-1sepzuflzk0.png?v=1776138241","url":"https:\/\/www.plcprotech.com\/fr\/products\/x67ps1300-b-r-x67-system-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}