{"product_id":"yokogawa-aai143-s50-s1-analog-input-module","title":"Module d'entrée analogique Yokogawa AAI143-S50 S1","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI143-S50 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Analog Input Module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindustrial automation systems. It features 16 channels designed to interface with 4 to 20 mA field signals from transmitters, ensuring high precision and electrical isolation for critical process data.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAAI143\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-S50 S1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16, isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$250 \\Omega$\u003c\/span\u003e (approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 0.1\\%$\u003c\/span\u003e of span\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms \/ 16 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC between input and system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eSuffix Code Breakdown\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard conversion speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways 0 (Basic specification).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the hardware is equipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePressure Clamp Terminal Blocks\u003c\/strong\u003e. This design provides a secure, vibration-resistant connection without the need for ring lugs, ideal for high-density cabinet wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of scanning all 16 channels in 10 ms, making it suitable for fast-acting control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports redundant configuration when used with a compatible duplex field control station (FCS), ensuring process uptime even if one module fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports digital signal superposition, allowing for remote configuration and diagnostics of HART-enabled field instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel is isolated from the system electronics, protecting the main controller from field-side electrical surges or ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1. Strip the wire insulation (approx. 7 mm).\u003c\/p\u003e\n\u003cp\u003e2. Insert the wire into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePressure Clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eopening.\u003c\/p\u003e\n\u003cp\u003e3. Tighten the screw to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 - 0.6 N·m\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing multiple high-density AAI143 modules, ensure the cabinet has adequate airflow. High-density analog modules can generate significant heat during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted-pair shielded cable (minimum 0.5\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$mm^2$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor 20 AWG) to maintain signal integrity and meet EMC requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"S1\" Pressure Clamp over standard screws?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S1 pressure clamp uses a compression plate to hold the wire. This prevents the screw from \"shredding\" the copper strands of the cable and maintains a constant tension that is superior in high-vibration environments compared to standard direct-screw terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module power the transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the AAI143 is an \"Input\" module that typically provides the loop power (24 VDC) for 2-wire transmitters, or it can be configured to receive signals from 4-wire (externally powered) transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle unused channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is best practice to short-circuit unused channels or disable them in the software configuration to prevent the system from generating \"Open Circuit\" or \"Out of Range\" alarms\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695403561323,"sku":"AAI143-S50 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-aai143-s50-s1-analog-input-module-ls0nuvlydgf_4e04f162-445b-431c-9fab-ddd1258c02d7.jpg?v=1766133916","url":"https:\/\/www.plcprotech.com\/fr\/products\/yokogawa-aai143-s50-s1-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}