{"product_id":"yokogawa-adv142-p13-s1-centum-vp-ac-digital-input-module","title":"Module d'entrée numérique AC CENTUM VP Yokogawa ADV142-P13 S1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142-P13 S1 (ADV142)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust 16-channel isolated digital input module designed for the Yokogawa CENTUM VP distributed control system (DCS). Specifically engineered to interface with high-voltage 200 V to 240 V AC signals, this module is essential for monitoring the status of heavy-duty industrial equipment such as motor starters, switchgear, and large-scale actuators. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures integrated pushbutton input logic, allowing for the precise counting of signal edges in operator-interface applications. This unit is built for extreme reliability, featuring ISA Standard G3 conformal coating to resist corrosive gases and an extended operating temperature range of -20 to 70 deg C. By supporting dual-redundant configurations and providing high-level galvanic isolation, the module ensures continuous process monitoring and significantly reduces the risk of unplanned downtime in harsh environments like oil refineries, power plants, and chemical processing facilities.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe suffix codes for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142-P13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefine its specialized hardware hardening and functional capabilities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with the Pushbutton Input function, allowing the module to detect and count the edges of pushbutton signals with a dedicated minimum detection time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCategorized as a General-purpose type, optimized for standard high-voltage AC sensing within the FIO subsystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes the ISA Standard G3 corrosion resistance option and the extended ambient temperature option (-20 to 70 deg C).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the Style 1 hardware revision, ensuring compatibility with current CENTUM VP node units and field network I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eADV142-P13 S1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16, isolated (8 channels per common)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 to 240 V AC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput ON Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 V AC (226 V Peak) to 264 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput OFF Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 V AC (56 V Peak) or less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWithstanding Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kV AC (Input to System) \/ 1.35 kV AC (Between Commons)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironmental Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 (Conformal Coating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the G3 option benefit the module's lifespan?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe G3 option applies a specialized conformal coating that protects internal circuitry from atmospheric corrosion caused by gases like Hydrogen Sulfide (H2S), Chlorine (Cl2), and Nitrogen Dioxide (NO2), which are common in paper mills and wastewater treatment plants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the critical phase requirement for wiring this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll AC input signals connected to the same common minus (-) side (grouped every 8 channels) must be on the same electrical phase. Connecting multiple phases to a single common can cause catastrophic hardware failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle high-frequency pulse signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas a pushbutton counting function, it is limited to a maximum cycle of 2.5 Hz. For high-speed pulse counting (up to 10 kHz), a dedicated pulse input module like the AAP135 is required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocesses potentials up to 264 V AC. Ensure all field power is isolated before wiring the pressure clamp terminals. Use 1.25 mm2 or smaller cross-sectional area wire and verify that the terminal covers are securely installed to prevent accidental contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen operating at the upper limit of the temperature range (up to 70 deg C), ensure the control cabinet has active ventilation. Avoid placing high-heat generating modules (like power supplies) directly beneath the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent localized overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo minimize electromagnetic interference (EMI), route the high-voltage AC input cables away from low-voltage DC signal lines. Use shielded cables if the wiring run exceeds 50 meters, and ground the shield at the cabinet end only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor reliable high-density connections, the use of the Yokogawa AKB333 dedicated cable is recommended. This cable is specifically designed to meet the insulation requirements for 220 V AC signals across 16 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695399137643,"sku":"ADV142-P13 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-adv142-p13-s1-digital-input-module-fpjon21xc0c_5ca3c41b-3a84-4679-8c7c-b9a3406ee3a9.jpg?v=1766133606","url":"https:\/\/www.plcprotech.com\/fr\/products\/yokogawa-adv142-p13-s1-centum-vp-ac-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}