{"product_id":"yokogawa-aip830-101-operation-keyboard","title":"Clavier d'exploitation pour CENTUM VP Yokogawa AIP830-101","description":"\u003ch3 data-path-to-node=\"1\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe \u003cb data-path-to-node=\"2\" data-index-in-node=\"4\"\u003eAIP830-101 (AIP830-101)\u003c\/b\u003e is a specialized \u003cb data-path-to-node=\"2\" data-index-in-node=\"45\"\u003eOperation Keyboard\u003c\/b\u003e designed for the Human Interface Station (HIS) within the Yokogawa \u003cb data-path-to-node=\"2\" data-index-in-node=\"131\"\u003eCENTUM VP\u003c\/b\u003e Distributed Control System (DCS). Unlike a standard PC keyboard, the \u003cb data-path-to-node=\"2\" data-index-in-node=\"210\"\u003eAIP830-101\u003c\/b\u003e is engineered specifically for process control operators, featuring dedicated functional keys for rapid alarm response, window switching, and loop tuning. This keyboard is essential for high-stress control room environments—such as power plants and refineries—where every second counts during a process upset. It connects via a USB interface and is built with industrial-grade durability to withstand 24\/7 continuous operation.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eFunctional Design \u0026amp; Operator Efficiency\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eYokogawa AIP830-101\u003c\/b\u003e architecture is centered on ergonomic efficiency and critical response. It includes a section for \u003cb data-path-to-node=\"4\" data-index-in-node=\"122\"\u003eOne-Touch Function Keys\u003c\/b\u003e (F1–F64 via shift), allowing operators to instantly call up specific process graphics or trend groups. The integrated \u003cb data-path-to-node=\"4\" data-index-in-node=\"264\"\u003eControl Keys\u003c\/b\u003e (Acknowledge, Stop, Reset) provide a tactile, hardware-level interface for handling system alarms, which is significantly faster and more reliable than navigating with a mouse during emergencies. The keyboard also features a dedicated numeric keypad and a set of window-call keys that integrate seamlessly with the CENTUM VP software environment.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"6\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,0,0\"\u003e\u003cb data-path-to-node=\"6,1,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,1,1,0\"\u003e\u003cb data-path-to-node=\"6,1,1,0\" data-index-in-node=\"0\"\u003eAIP830-101\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,0,0\"\u003e\u003cb data-path-to-node=\"6,2,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,2,1,0\"\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,3,0,0\"\u003e\u003cb data-path-to-node=\"6,3,0,0\" data-index-in-node=\"0\"\u003eSeries\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,3,1,0\"\u003eCENTUM VP \/ HIS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,0,0\"\u003e\u003cb data-path-to-node=\"6,4,0,0\" data-index-in-node=\"0\"\u003eInterface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,4,1,0\"\u003eUSB (Standard Type A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,5,0,0\"\u003e\u003cb data-path-to-node=\"6,5,0,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,5,1,0\"\u003e5 VDC (Supplied via USB port)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,6,0,0\"\u003e\u003cb data-path-to-node=\"6,6,0,0\" data-index-in-node=\"0\"\u003eMax Current Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,6,1,0\"\u003e100 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,7,0,0\"\u003e\u003cb data-path-to-node=\"6,7,0,0\" data-index-in-node=\"0\"\u003eKeyboard Layout\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,7,1,0\"\u003eOperation-specific (Function, Window-call, and Control keys)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,8,0,0\"\u003e\u003cb data-path-to-node=\"6,8,0,0\" data-index-in-node=\"0\"\u003eOperating Temp\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,8,1,0\"\u003e5 to 40 deg C (41 to 104 Celsius)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,0,0\"\u003e\u003cb data-path-to-node=\"6,9,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,9,1,0\"\u003e~2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,10,0,0\"\u003e\u003cb data-path-to-node=\"6,10,0,0\" data-index-in-node=\"0\"\u003eShipping Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"6,10,1,0\"\u003e4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eHow does the AIP830-101 improve safety compared to a standard keyboard?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eIn a critical alarm scenario, an operator may need to silence a buzzer or acknowledge an alarm instantly. The \u003cb data-path-to-node=\"8\" data-index-in-node=\"182\"\u003eAIP830-101\u003c\/b\u003e provides a dedicated \"Global ACK\" key that works regardless of which software window is currently focused, ensuring that safety-critical actions are never delayed by software navigation.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eIs the AIP830-101 compatible with standard Windows PCs?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eWhile it uses a USB interface, its full functionality (specifically the custom function and control keys) requires the \u003cb data-path-to-node=\"9\" data-index-in-node=\"175\"\u003eYokogawa HIS software\u003c\/b\u003e and drivers. Without the CENTUM VP environment, it may only function as a basic alphanumeric keyboard.\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eWhat is the difference between the AIP830 and AIP831 models?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe \u003cb data-path-to-node=\"10\" data-index-in-node=\"65\"\u003eAIP830\u003c\/b\u003e is the standard operation keyboard, whereas the \u003cb data-path-to-node=\"10\" data-index-in-node=\"120\"\u003eAIP831\u003c\/b\u003e usually includes additional features like a built-in pointing device (trackball) or different layout variations for specific regional or system requirements. The \"-101\" suffix specifically denotes the English\/Standard version.\u003c\/p\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eDriver Configuration:\u003c\/b\u003e Ensure the \"Keyboard Driver for Operation Keyboard\" is selected during the HIS software installation. If the custom keys are non-responsive after a Windows update, check the Device Manager to ensure the Yokogawa-specific HID driver is correctly mapped to the USB port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eEnvironmental Protection:\u003c\/b\u003e While industrial-grade, the \u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"54\"\u003eAIP830-101\u003c\/b\u003e is an electronic component. Avoid placing it in areas where liquid spills are likely. In dusty environments, use a silicone keyboard protector designed specifically for the AIP830 series to prevent mechanical sticking of the high-travel keys.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eCable Management:\u003c\/b\u003e Use the provided USB cable and avoid using unpowered USB hubs. For long-distance connections (e.g., if the HIS PC is in a rack room), use high-quality active USB extenders to maintain signal integrity for the rapid keystroke data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp data-path-to-node=\"15\"\u003eThe \u003cb data-path-to-node=\"15\" data-index-in-node=\"4\"\u003eAIP830-101\u003c\/b\u003e represents Yokogawa’s commitment to \"Human-Machine Interface\" (HMI) excellence. Its mechanical switches are rated for millions of actuations, providing the \"tactile feedback\" that operators rely on when they cannot look away from the process screen. By standardizing the operator's physical workspace, Yokogawa ensures that a technician trained on one CENTUM VP system can walk into any control room worldwide and instantly navigate the process using a familiar, high-performance interface.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695401890155,"sku":"AIP830-101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-aip830-101-operation-keyboard-len2sivdghd_a36a8f22-79c0-490a-beea-d79148453aaf.jpg?v=1766133775","url":"https:\/\/www.plcprotech.com\/fr\/products\/yokogawa-aip830-101-operation-keyboard","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}