{"product_id":"yokogawa-cp471-00-centum-vp-processor-module","title":"Module processeur CENTUM VP Yokogawa CP471-00","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa CP471-00\u003c\/strong\u003e is a high-performance \u003cstrong\u003eProcessor Module\u003c\/strong\u003e designed for deployment within \u003cstrong\u003eCENTUM VP\u003c\/strong\u003e distributed control systems (DCS). This module mounts directly onto compatible field control units (FCUs) and serves as the primary processing core executing field control station functions. The \u003cstrong\u003eCP471-00\u003c\/strong\u003e supports high-availability operations, allowing dual-redundant configurations where two units are installed side-by-side in a duplexed field control unit to ensure continuous process automation and zero-downtime failover. It offers modern hardware architecture for executing complex logic, sequencing, and continuous control loop configurations required across industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-redundant configuration compatibility for uninterrupted control station failovers.\u003c\/li\u003e\n\u003cli\u003eSupports on-line replacement capabilities when deployed in active dual-redundant configurations.\u003c\/li\u003e\n\u003cli\u003eDirectly replaces older CP461 modules via verified migration paths.\u003c\/li\u003e\n\u003cli\u003eStandard non-explosion protection basic design layout optimized for standard technical spaces.\u003c\/li\u003e\n\u003cli\u003eNative integration with ESB bus coupler module configurations for field peripheral connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) for continuous process industries.\u003c\/li\u003e\n\u003cli\u003ePetrochemical, chemical, and refining facility automation.\u003c\/li\u003e\n\u003cli\u003ePower plant control and infrastructure utility networks.\u003c\/li\u003e\n\u003cli\u003eFactory automation control loops and field-level sequence processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Codes\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCP471\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProcessor Module (for AFV30\/AFV40\/A2FV500\/A2FV700) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWith no explosion protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBasic type \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cblockquote\u003e\u003c\/blockquote\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP471-00 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Function Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP R6.05 or later \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 700 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Width)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e199.5 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Depth)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e146.5 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Tolerances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.8 mm (for dimensions 0.5 mm to 120 mm); In accordance with JEM 1459 for dimensions over 120 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Accessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcessor Module Modification History Label (Part Number: T9044AR, Qty: 1) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting:\u003c\/strong\u003e The device must be mounted strictly on compatible field control units, including AFV30S, AFV30D, AFV40S, AFV40D, A2FV50S, A2FV50D, A2FV70S, and A2FV70D units according to regional regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Coupling:\u003c\/strong\u003e Must be combined exclusively with style code S3 or later of the ESB bus coupler module EC401.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCP461 Upgrades:\u003c\/strong\u003e While a pair of CP461 modules in an active dual-redundant layout can be on-line replaced with a pair of these modules, they cannot co-exist with a CP461 unit within the same dual-redundant configuration slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonnel Restrictions:\u003c\/strong\u003e Upgrading an existing field control installation from a CP461 to this module must be executed exclusively by a Yokogawa authorized service engineer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Constraints:\u003c\/strong\u003e Once a station has been updated, replacing the active module back with an older CP461 unit is strictly prohibited.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Standards:\u003c\/strong\u003e Complies with applicable standards as an integral part of field control units AFV30, AFV40, A2FV50, and A2FV700. Refer to CENTUM VP System Overview (GS 33J01A10-01EN) for general environmental compliance and specific standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695383343467,"sku":"CP471-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-cp471-00-processor-module-lyacokwnpnb_9de5deb3-7305-471a-93db-1b6efcacc389.jpg?v=1766132535","url":"https:\/\/www.plcprotech.com\/fr\/products\/yokogawa-cp471-00-centum-vp-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}