{"title":"Siemens Industrial Net \u0026 Power","description":"\u003cp\u003eSiemens Industrial Net \u0026amp; Power solutions ensure reliable connectivity and energy management across the industrial floor. The architecture features SCALANCE network components (6GK prefix) and SITOP power supplies (6EP prefix) designed for 24\/7 industrial service. Technical characteristics include managed\/unmanaged switches with gigabit speeds, redundant power modules, and surge protection. Functionally, the 6GK series creates a robust communication backbone for \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/siemens-distributed-i-o\"\u003eDistributed I\/O\u003c\/a\u003e, while 6EP SITOP units provide clean, regulated DC power to sensitive \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/siemens-simatic-s7\"\u003eS7 PLC\u003c\/a\u003e hardware. These components prevent system downtime caused by network failures or power fluctuations, maintaining the high availability required for modern automated production lines.\u003c\/p\u003e","products":[{"product_id":"siemens-6gk5108-2bb00-2ab2-scalance-xb100-unmanaged-industrial-ethernet-switch","title":"Siemens 6GK5108-2BB00-2AB2 SCALANCE XB100 Unmanaged Industrial Ethernet Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6GK5108-2BB00-2AB2\u003c\/strong\u003e is an unmanaged industrial Ethernet switch from the \u003cstrong\u003eSCALANCE XB100\u003c\/strong\u003e series, engineered for reliable and straightforward network deployment within automation environments. This device provides eight \u003cstrong\u003eRJ45\u003c\/strong\u003e ports supporting 10\/100 Mbit\/s speeds, complemented by two additional 100 Mbit\/s multimode fiber optic (\u003cstrong\u003eBFOC\u003c\/strong\u003e) ports, offering versatile connectivity for mixed media applications. It is designed for establishing small-scale star and line topologies, making it suitable for connecting industrial devices in various layouts. The \u003cstrong\u003e6GK5108-2BB00-2AB2\u003c\/strong\u003e features LED-based diagnostics for quick visual status monitoring and supports a redundant 24 V AC\/DC power supply for enhanced operational reliability. With an \u003cstrong\u003eIP20\u003c\/strong\u003e protection rating, it is suited for control cabinet installation and offers plug-and-play functionality with no configuration required.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnmanaged Industrial Ethernet Switch\u003c\/li\u003e\n\u003cli\u003e8 x RJ45 ports with 10\/100 Mbit\/s speed\u003c\/li\u003e\n\u003cli\u003e2 x 100 Mbit\/s Multimode Fiber Optic (BFOC) ports\u003c\/li\u003e\n\u003cli\u003eSupports star and line network topologies\u003c\/li\u003e\n\u003cli\u003eLED-based diagnostics for status monitoring\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating for control cabinet installation\u003c\/li\u003e\n\u003cli\u003eRedundant 24 V AC\/DC power supply support\u003c\/li\u003e\n\u003cli\u003ePlug-and-play functionality, no configuration required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEstablishing small-scale star and line topologies in industrial networks.\u003c\/li\u003e\n\u003cli\u003eConnecting industrial devices in confined or distributed automation layouts.\u003c\/li\u003e\n\u003cli\u003eDeployment in control cabinets for industrial Ethernet communication.\u003c\/li\u003e\n\u003cli\u003eAutomation settings requiring reliable and straightforward network integration.\u003c\/li\u003e\n\u003cli\u003eSystems utilizing PLC communication for data exchange.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5108-2BB00-2AB2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Switches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE XB100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCondition\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand New\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGERMANY\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eStatus\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommunication Service\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet router\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 (10\/100 Mbit\/s)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eFiber Optic Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 (100 Mbit\/s, Multimode BFOC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eNetwork Topology\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStar, Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundant 24 V AC\/DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.95 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eHS CODE\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8537101190\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and connected devices is de-energized before beginning installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the switch within a control cabinet, ensuring adequate ventilation and clearance for cable routing and heat dissipation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the redundant 24 V AC\/DC power supply to the designated terminals, observing correct polarity. Ensure the power source meets the specified voltage requirements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Connections:\u003c\/strong\u003e Connect industrial devices to the RJ45 ports using appropriate Ethernet cables. For longer distances or specific media requirements, utilize the BFOC multimode fiber optic ports.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route all cables to minimize stress on connectors and to avoid interference with other electrical components. Use proper cable management techniques.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding of the control cabinet and the switch itself, if applicable, to protect against electrical noise and surges.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e After installation, re-energize the system and observe the LED indicators on the switch to confirm proper operation and network link status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695203578219,"sku":"6GK5108-2BB00-2AB2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6gk5108-2bb00-2ab2-ethernet-switches-dd4r2rju2hz_b5631014-b84f-4dba-bc8e-88abbef49e78.jpg?v=1766130599"},{"product_id":"siemens-6gk1503-2cb00-profibus-olm-g11-v4-0-optical-link-module","title":"Siemens 6GK1503-2CB00 PROFIBUS OLM\/G11 V4.0 Optical Link Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK1503-2CB00\u003c\/strong\u003e is a PROFIBUS OLM\/G11 V4.0 optical link module designed to provide reliable communication within industrial automation networks. This module integrates one \u003cstrong\u003eRS485 electrical interface\u003c\/strong\u003e with a single glass fiber optic cable interface, featuring two \u003cstrong\u003eBFOC sockets\u003c\/strong\u003e for flexible and efficient data transmission over extended distances. It ensures stable connectivity and precise signal transfer, making it suitable for demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK1503-2CB00\u003c\/strong\u003e supports a wide range of PROFIBUS transfer rates, from \u003cstrong\u003e9.6 kbit\/s to 12 Mbit\/s\u003c\/strong\u003e, and also includes support for \u003cstrong\u003e45.45 kbit\/s\u003c\/strong\u003e for PROFIBUS PA applications. This versatility allows for seamless integration into existing PROFIBUS networks while maintaining high data integrity. For enhanced operational reliability, the module incorporates a signaling contact and a dedicated test port for straightforward monitoring and maintenance.\u003c\/p\u003e\n\u003cp\u003eOperating with a rated supply voltage of \u003cstrong\u003e24 V DC\u003c\/strong\u003e and an operational range from \u003cstrong\u003e18.8 to 28.8 V DC\u003c\/strong\u003e, the Siemens \u003cstrong\u003e6GK1503-2CB00\u003c\/strong\u003e is engineered for reliable function under varying power conditions. It also features a built-in fuse at the power supply input, providing protection against potential electrical faults and contributing to increased system safety and longevity. With its robust performance and compact design, the module facilitates dependable optical communication in harsh industrial settings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePROFIBUS OLM\/G11 V4.0 Optical Link Module.\u003c\/li\u003e\n  \u003cli\u003eCombines one RS485 electrical interface with a glass fiber optic interface.\u003c\/li\u003e\n  \u003cli\u003eEquipped with two BFOC sockets for fiber optic cable connection.\u003c\/li\u003e\n  \u003cli\u003eSupports PROFIBUS transfer rates from 9.6 kbit\/s to 12 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003eIncludes support for 45.45 kbit\/s for PROFIBUS PA applications.\u003c\/li\u003e\n  \u003cli\u003eFeatures a signaling contact and a dedicated test port for diagnostics.\u003c\/li\u003e\n  \u003cli\u003eRated supply voltage of 24 V DC with an operational range of 18.8 to 28.8 V DC.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in fuse at the power supply input for electrical protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation networks requiring PROFIBUS communication.\u003c\/li\u003e\n  \u003cli\u003eSystems needing conversion between RS485 electrical and fiber optic PROFIBUS segments.\u003c\/li\u003e\n  \u003cli\u003eApplications requiring extended PROFIBUS network distances.\u003c\/li\u003e\n  \u003cli\u003eIntegration into existing PROFIBUS DP and PROFIBUS PA infrastructures.\u003c\/li\u003e\n  \u003cli\u003eDeployment in demanding industrial environments where robust data transmission is critical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003e6GK1503-2CB00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eOptical Link Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Status\u003c\/td\u003e\n      \u003ctd\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eGERMANY\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003ePLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Service\u003c\/td\u003e\n      \u003ctd\u003eEthernet router\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s (PROFIBUS), 45.45 kbit\/s (PROFIBUS PA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x RS485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptical Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x Glass Fiber Optic, 2 x BFOC sockets\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperational Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e18.8 to 28.8 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection\u003c\/td\u003e\n      \u003ctd\u003eBuilt-in fuse at power supply input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnit Weight\u003c\/td\u003e\n      \u003ctd\u003e0.34 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e0.95 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHS CODE\u003c\/td\u003e\n      \u003ctd\u003e8537101190\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Order Quantity (MOQ)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect the module to a stable 24 V DC power source. Ensure the supply voltage remains within the operational range of 18.8 V DC to 28.8 V DC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e Connect the RS485 electrical interface to the PROFIBUS DP segment using appropriate shielded cabling and termination practices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFiber Optic Connection:\u003c\/strong\u003e Connect the glass fiber optic cable to the two BFOC sockets. Ensure proper fiber polarity and secure connections to maintain signal integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding of the module and associated cabling to minimize electromagnetic interference and ensure safe operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Integrate the module into the PROFIBUS network configuration according to the system's design and addressing scheme.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Utilize the signaling contact and test port for initial commissioning checks and ongoing operational monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Always de-energize the system before making or breaking electrical connections to prevent electrical shock or damage to components.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695204004203,"sku":"6GK1503-2CB00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6gk1503-2cb00-optical-link-module-ioehrg11xzk_cac25ddb-1773-4c86-b705-8e65997044c1.jpg?v=1766130613"},{"product_id":"siemens-6gk1503-3cb00-simatic-net-profibus-olm-g12-v4-0-optical-link-module","title":"Siemens 6GK1503-3CB00 SIMATIC NET PROFIBUS OLM\/G12 V4.0 Optical Link Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6GK1503-3CB00\u003c\/strong\u003e is a PROFIBUS Optical Link Module (OLM) designed to extend and segment industrial network infrastructure using fiber optic connectivity. Designated as version G12 V4.0, this module integrates one electrical \u003cstrong\u003eRS485 interface\u003c\/strong\u003e and two independent optical fiber channels, utilizing four \u003cstrong\u003eBFOC sockets\u003c\/strong\u003e for bidirectional communication. It enables robust signal transmission over extended distances, up to 2,850 meters with standard glass fiber optic cables, providing complete electrical isolation between network segments and surpassing the limitations of conventional copper-based PROFIBUS networks.\u003c\/p\u003e\n\u003cp\u003eEngineered for demanding industrial environments, the \u003cstrong\u003e6GK1503-3CB00\u003c\/strong\u003e features comprehensive diagnostic capabilities, including a signaling contact for remote monitoring and a measuring output for precise signal quality assessment. Its rugged construction ensures reliable operation in harsh industrial settings prone to electromagnetic interference, ground potential differences, or extreme environmental conditions. The module facilitates the creation of redundant ring topologies and star configurations within PROFIBUS networks, enhancing system reliability and actively regenerating and amplifying PROFIBUS signals to maintain integrity across extensive facilities. It is particularly valuable in applications requiring isolation between different electrical areas or protection against lightning-induced surges.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePROFIBUS Optical Link Module (OLM) for network extension and segmentation\u003c\/li\u003e\n\u003cli\u003eOne electrical RS485 interface\u003c\/li\u003e\n\u003cli\u003eTwo independent optical fiber channels with four BFOC sockets\u003c\/li\u003e\n\u003cli\u003eSupports transmission distances up to 2,850 meters with standard glass fiber\u003c\/li\u003e\n\u003cli\u003eProvides complete electrical isolation between network segments\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic capabilities: signaling contact and measuring output\u003c\/li\u003e\n\u003cli\u003eFacilitates redundant ring and star PROFIBUS network topologies\u003c\/li\u003e\n\u003cli\u003eActive signal regeneration and amplification\u003c\/li\u003e\n\u003cli\u003eRugged construction for reliable operation in harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtending PROFIBUS network reach in large industrial facilities and process plants\u003c\/li\u003e\n\u003cli\u003eSegmenting PROFIBUS networks for improved performance and fault isolation\u003c\/li\u003e\n\u003cli\u003eProviding electrical isolation between network segments to mitigate ground potential differences and electromagnetic interference\u003c\/li\u003e\n\u003cli\u003eImplementing redundant PROFIBUS network topologies (ring and star) for enhanced system reliability\u003c\/li\u003e\n\u003cli\u003eProtecting PROFIBUS networks against lightning-induced surges in outdoor or exposed installations\u003c\/li\u003e\n\u003cli\u003eDeploying PROFIBUS communication in environments with high electrical noise or harsh conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK1503-3CB00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Link Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens SIMATIC NET\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eVersion\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eG12 V4.0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eElectrical Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x RS485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x Fiber Optic Channels (4 x BFOC Sockets)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax Transmission Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2,850 meters (with standard glass fiber)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDiagnostic Capabilities\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSignaling contact, Measuring output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Service\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet router\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCondition\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand New\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGERMANY\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.95 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHS Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8537101190\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMinimum Order Quantity (MOQ)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLead Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIn Stock\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDescription\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eElectrical Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x RS485 Interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x Fiber Optic Channels (4 x BFOC Sockets)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the PROFIBUS network and associated equipment is disconnected before installation or maintenance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the OLM in a suitable industrial enclosure, typically on a DIN rail, ensuring adequate ventilation and clearance for cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFiber Optic Connection:\u003c\/strong\u003e Carefully connect the fiber optic cables to the BFOC sockets. Ensure all fiber ends are clean and free of dust or debris. Observe the minimum bend radius for the fiber optic cables to prevent damage and signal loss.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRS485 Connection:\u003c\/strong\u003e Connect the PROFIBUS RS485 segment to the electrical interface. Pay close attention to proper polarity (A and B lines) and ensure the shield is correctly terminated and grounded to minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect the module to its specified power supply. Verify correct voltage and current ratings as per system requirements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the module and its associated equipment are properly grounded to provide electrical safety and reduce noise.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route all cables (power, RS485, fiber optic) neatly and separately where possible to avoid interference. Secure cables to prevent strain on connectors.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Configuration:\u003c\/strong\u003e After physical installation, configure the PROFIBUS network and OLM parameters as required by the application, including addressing and diagnostic settings.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e Utilize the integrated signaling contact and measuring output to monitor the health and signal quality of the fiber optic connections during commissioning and operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695216128363,"sku":"6GK1503-3CB00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6gk1503-3cb00-optical-link-module-3rofijnbjjl_c0ac8a94-fb7f-4663-b840-29e5d8a48d44.jpg?v=1766130942"},{"product_id":"siemens-6gk5552-0aa00-2ar2-scalance-xr552-12m-managed-ie-switch","title":"Siemens 6GK5552-0AA00-2AR2 SCALANCE XR552-12M Managed IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5552-0AA00-2AR2\u003c\/strong\u003e is a SCALANCE XR552-12M managed Industrial Ethernet switch designed for 19-inch rack mounting. This robust switch features 4x 1000\/10000 Mbit\/s SFP+ ports and supports 12x 100\/1000 Mbit\/s 4-port media modules, which can be electrical, electrical PoE, or optical, offering versatile connectivity options. It includes LED diagnostics, an error signaling contact, and a Select\/set pushbutton for local interaction. The device functions as a PROFINET IO device, supports comprehensive network management, and integrates a redundancy manager for enhanced network reliability. It also incorporates various office features such as RSTP, VLAN, and IGMP. The \u003cstrong\u003e6GK5552-0AA00-2AR2\u003c\/strong\u003e is Layer 3 prepared and comes with a C-plug in the scope of delivery, with all ports conveniently located on the front.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Industrial Ethernet Switch\u003c\/li\u003e\n\u003cli\u003e19-inch Rack Mountable Design\u003c\/li\u003e\n\u003cli\u003e4x 1000\/10000 Mbit\/s SFP+ Ports\u003c\/li\u003e\n\u003cli\u003eSupports 12x 100\/1000 Mbit\/s 4-Port Media Modules (electrical, PoE, optical)\u003c\/li\u003e\n\u003cli\u003eLED Diagnostics and Error Signaling Contact\u003c\/li\u003e\n\u003cli\u003ePROFINET IO Device Functionality\u003c\/li\u003e\n\u003cli\u003eIntegrated Redundancy Manager for Network Reliability\u003c\/li\u003e\n\u003cli\u003eLayer 3 Prepared\u003c\/li\u003e\n\u003cli\u003eIncludes C-plug in Scope of Delivery\u003c\/li\u003e\n\u003cli\u003eFront-facing Ports for Easy Access\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial network infrastructure in manufacturing and process automation\u003c\/li\u003e\n\u003cli\u003eHigh-speed data communication in PROFINET-based systems\u003c\/li\u003e\n\u003cli\u003eDeployment in redundant network architectures for increased availability\u003c\/li\u003e\n\u003cli\u003eIntegration of diverse media types (copper, fiber, Power over Ethernet) within industrial environments\u003c\/li\u003e\n\u003cli\u003eCentralized network management and diagnostics in control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDigital modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e44.90 x 30.50 x 13.08 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e11.58 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4x 1000\/10000 Mbit\/s SFP+ ports\u003c\/li\u003e\n\u003cli\u003e12x 100\/1000 Mbit\/s 4-port media module slots (for electrical, electrical PoE, or optical modules)\u003c\/li\u003e\n\u003cli\u003eError signaling contact\u003c\/li\u003e\n\u003cli\u003eSelect\/set pushbutton\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the SCALANCE XR552-12M into a standard 19-inch equipment rack, ensuring proper ventilation and secure fastening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia Module Installation:\u003c\/strong\u003e Insert the required 100\/1000 Mbit\/s 4-port media modules (electrical, PoE, or optical) into the designated slots on the front panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSFP+ Connection:\u003c\/strong\u003e Connect high-speed fiber optic cables to the 1000\/10000 Mbit\/s SFP+ ports as per network design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect the appropriate power supply to the device, utilizing the included C-plug. Ensure power is de-energized before making connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Integration:\u003c\/strong\u003e Configure the switch as a PROFINET IO device within the engineering software for seamless integration into the automation system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Configuration:\u003c\/strong\u003e Set up network parameters, including VLANs, RSTP, and IGMP, via the network management interface to optimize traffic and redundancy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the switch chassis is properly grounded to the rack and facility ground for electrical safety and EMC compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Monitor the LED diagnostics indicators on the front panel to verify operational status and identify any potential issues.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715764318571,"sku":"6GK5552-0AA00-2AR2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5552-0aa00-2ar2-vrcisw2wz4m_f305b744-4b45-4002-8ba6-0b9cb36ce170.jpg?v=1767070527"},{"product_id":"siemens-6gk5992-2aq00-8aa0-scalance-x-media-module-mm992-2elh","title":"Siemens 6GK5992-2AQ00-8AA0 SCALANCE X Media Module MM992-2ELH","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5992-2AQ00-8AA0 is a media module, model MM992-2ELH, designed for use with the SCALANCE X series of industrial Ethernet switches. This module provides two \u003cstrong\u003e1000 Mbit\/s SC fiber optic ports\u003c\/strong\u003e for establishing long-distance network connections. It is engineered to support \u003cstrong\u003esingle-mode fiber\u003c\/strong\u003e optic cabling, enabling reliable data transmission over distances up to a maximum of \u003cstrong\u003e120 km\u003c\/strong\u003e. Please note, this product is in the 'Phase-Out' stage of its lifecycle, making it suitable for spare parts inventory and maintenance of existing systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides two 1000 Mbit\/s SC ports\u003c\/li\u003e\n  \u003cli\u003eSupports single-mode optical fiber\u003c\/li\u003e\n  \u003cli\u003eEnables long-distance communication up to 120 km\u003c\/li\u003e\n  \u003cli\u003eDesigned as an accessory for SCALANCE X switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLong-haul industrial network backbones\u003c\/li\u003e\n  \u003cli\u003eConnecting geographically dispersed facilities or control centers\u003c\/li\u003e\n  \u003cli\u003eHigh-bandwidth data links in utility, transportation, and manufacturing\u003c\/li\u003e\n  \u003cli\u003eExtending network infrastructure in large industrial campuses\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc; color: #2d3748; font-weight: 600;\"\u003eCategory\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc; color: #2d3748; font-weight: 600;\"\u003eDetail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eMedia Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eMM992-2ELH\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6GK5992-2AQ00-8AA0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eSCALANCE X\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eNumber of Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003ePort Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eSC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eData Rate\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eSupported Fiber Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eSingle-mode optical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eMaximum Transmission Distance\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e120 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003e0.24 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e6.0 cm x 10.0 cm x 2.2 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eUSA (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px 12px; background-color: #f8fafc;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Always de-energize the host SCALANCE switch and follow lock-out\/tag-out (LOTO) procedures before installing or removing media modules. Failure to disconnect power can result in equipment damage and risk of electric shock. Handle fiber optic cables with care to avoid damage to the core and connectors.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eVerify that the host SCALANCE X switch is powered down and that the target slot for the media module is clean and free of debris.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eUse a properly grounded electrostatic discharge (ESD) wrist strap to prevent static damage to the module's electronic components.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eCarefully unpack the MM992-2ELH module. Do not remove the protective dust caps from the SC ports until you are ready to connect the fiber optic cables.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eAlign the module with the guides in the empty slot on the SCALANCE switch and slide it in gently until it is fully seated and clicks into place.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eClean the ferrules of the single-mode fiber optic cables using appropriate fiber optic cleaning tools. Remove the dust caps from the module's SC ports and connect the cables.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eOnce all connections are secure, you may re-energize the SCALANCE switch. Verify the link status LEDs on the module to confirm a successful connection.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715858198891,"sku":"6GK5992-2AQ00-8AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5992-2aq00-8aa0-nwvcgucwckv_21f1bdb1-8eb3-4440-8e4d-412f81cf7d45.jpg?v=1767072917"},{"product_id":"siemens-6gk1411-6ca40-0aa0-ie-wsn-pa-link-module","title":"Siemens 6GK1411-6CA40-0AA0 IE\/WSN-PA Link Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6GK1411-6CA40-0AA0\u003c\/strong\u003e is an IE\/WSN-PA Link module with an integrated antenna, designed for seamless network transition between WirelessHART and Ethernet environments. This module supports Ethernet communication at 10\/100 Mbit\/s, utilizing protocols such as TCP\/IP and Modbus TCP. For wireless connectivity, it operates with WirelessHART at 2.4 GHz, and also includes an RS 485 interface with Modbus R support. It holds national approvals for use in USA, Canada, and Europe, and features EX-certification for Zone 2 hazardous areas, making it suitable for various industrial applications requiring robust communication links.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eIntegrated antenna for WirelessHART communication\u003c\/li\u003e\n    \u003cli\u003eNetwork transition between WirelessHART and Ethernet\u003c\/li\u003e\n    \u003cli\u003eEthernet interface: 10\/100 Mbit\/s\u003c\/li\u003e\n    \u003cli\u003eSupports TCP\/IP and Modbus TCP protocols\u003c\/li\u003e\n    \u003cli\u003eWirelessHART communication at 2.4 GHz\u003c\/li\u003e\n    \u003cli\u003eRS 485 interface with Modbus R support\u003c\/li\u003e\n    \u003cli\u003eNational approvals for USA, Canada, and Europe\u003c\/li\u003e\n    \u003cli\u003eEX-certification for Zone 2 hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK1411-6CA40-0AA0 module is typically deployed in industrial automation settings where there is a need to integrate wireless field devices into existing wired Ethernet networks. Common applications include:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eProcess automation systems utilizing WirelessHART sensors and actuators.\u003c\/li\u003e\n    \u003cli\u003eRemote monitoring and control of industrial equipment in hazardous areas (Zone 2).\u003c\/li\u003e\n    \u003cli\u003eBridging communication between legacy RS 485 Modbus devices and modern Ethernet-based control systems.\u003c\/li\u003e\n    \u003cli\u003eEnhancing network flexibility and reducing wiring complexity in large-scale industrial plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eType of Product\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Module (IE\/WSN-PA Link)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Phase\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eEthernet Interface\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e10\/100 Mbit\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eWireless Interface\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWirelessHART 2.4 GHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSerial Interface\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRS 485\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eSupported Protocols\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTCP\/IP, Modbus TCP, Modbus R\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eEX-Certification\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eZone 2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eNational Approvals\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSA, Canada, Europe\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e58.90 x 30.70 x 5.00 cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4.54 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation ensures reliable operation and adherence to safety standards, especially in hazardous environments. Consider the following:\u003c\/p\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energization:\u003c\/strong\u003e Always ensure that all power to the installation area is disconnected and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module in a stable, vibration-free location, typically within an industrial enclosure. Ensure adequate ventilation to prevent overheating.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the module's designated grounding terminal to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route Ethernet, RS 485, and power cables separately from high-voltage or high-current lines to prevent signal interference. Use shielded cables where appropriate for industrial environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAntenna Placement:\u003c\/strong\u003e As the module has an integrated antenna, ensure it is positioned for optimal wireless signal reception and transmission, free from obstructions or metallic shielding that could degrade performance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e When installing in a Zone 2 hazardous area, strictly adhere to all local and national regulations, as well as the specific requirements outlined in the EX-certification documentation for the module.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the power supply according to the specified voltage and polarity. Verify connections before re-energizing the system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEX-certification:\u003c\/strong\u003e Zone 2\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNational Approvals:\u003c\/strong\u003e USA, Canada, Europe\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715862032747,"sku":"6GK1411-6CA40-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1411-6ca40-0aa0-mxvblrckkcr_5a553a3b-4463-4b48-a78e-a5eeb7174111.jpg?v=1767073063"},{"product_id":"siemens-6gk5526-8gs00-2ar2-scalance-xr526-8c-managed-ie-switch","title":"Siemens 6GK5526-8GS00-2AR2 SCALANCE XR526-8C Managed IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5526-8GS00-2AR2\u003c\/strong\u003e SCALANCE XR526-8C is a managed Layer 3 Industrial Ethernet switch. It features a 24 V DC power supply and a versatile port configuration including 24x 10\/100\/1000 Mbit\/s RJ45 ports, 8x 100\/1000 Mbit\/s SFP Combo ports, and 2x 10 Gbit\/s SFP+ ports, allowing for a total of 26 usable ports. Designed as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e, it supports redundancy functions and various office features such as RSTP, VLAN, and IGMP, making it suitable for complex industrial network infrastructures. An error signaling contact and a select\/set button are integrated for operational feedback and configuration. A C-plug is included in the scope of delivery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Layer 3 Industrial Ethernet switch\u003c\/li\u003e\n\u003cli\u003e24 V DC power supply\u003c\/li\u003e\n\u003cli\u003e24x 10\/100\/1000 Mbit\/s RJ45 ports\u003c\/li\u003e\n\u003cli\u003e8x 100\/1000 Mbit\/s SFP Combo ports\u003c\/li\u003e\n\u003cli\u003e2x 10 Gbit\/s SFP+ ports\u003c\/li\u003e\n\u003cli\u003eTotal of 26 usable ports\u003c\/li\u003e\n\u003cli\u003ePROFINET IO device functionality\u003c\/li\u003e\n\u003cli\u003eRedundancy functions support\u003c\/li\u003e\n\u003cli\u003eIntegrated office features (RSTP, VLAN, IGMP)\u003c\/li\u003e\n\u003cli\u003eError signaling contact and select\/set button\u003c\/li\u003e\n\u003cli\u003eC-plug included in scope of delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Ethernet networks requiring Layer 3 routing capabilities\u003c\/li\u003e\n\u003cli\u003ePROFINET-based automation systems\u003c\/li\u003e\n\u003cli\u003eApplications demanding high port density and diverse connectivity options (RJ45, SFP, SFP+)\u003c\/li\u003e\n\u003cli\u003eNetwork segments requiring redundancy and high availability\u003c\/li\u003e\n\u003cli\u003eIntegration into existing office IT networks with features like VLAN and IGMP\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type (from source)\u003c\/td\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports\u003c\/td\u003e\n\u003ctd\u003e24x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP Combo Ports\u003c\/td\u003e\n\u003ctd\u003e8x 100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports\u003c\/td\u003e\n\u003ctd\u003e2x 10 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Usable Ports\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLayer\u003c\/td\u003e\n\u003ctd\u003eLayer 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO, RSTP, VLAN, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eError Signaling\u003c\/td\u003e\n\u003ctd\u003eContact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eSelect\/Set Button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003eC-plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd\u003e44.90 cm x 30.50 cm x 4.40 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n\u003ctd\u003e5A002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and associated equipment is disconnected before beginning any work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the switch in an industrial enclosure or on a suitable mounting surface, typically a DIN rail or panel, ensuring adequate ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated terminals, observing correct polarity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connections:\u003c\/strong\u003e Connect Ethernet cables to the RJ45 ports and insert appropriate SFP\/SFP+ transceivers into the combo and SFP+ slots, then connect fiber optic cables as required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the device's grounding terminal to ensure electrical safety and EMC compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables neatly, separating power and signal cables to minimize interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on the device and perform initial configuration via the select\/set button or network interface as per system requirements.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716359090539,"sku":"6GK5526-8GS00-2AR2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5526-8gs00-2ar2-3qhgbdss5i2_3d11fc0c-2a69-42a8-9192-45e9a5cd4a85.jpg?v=1767081227"},{"product_id":"siemens-scalance-xr524-8c-6gk5524-8gs00-2ar2-managed-layer-3-ie-switch","title":"Siemens SCALANCE XR524-8C 6GK5524-8GS00-2AR2 Managed Layer 3 IE Switch","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5524-8GS00-2AR2 is a SCALANCE XR524-8C managed Layer 3 Industrial Ethernet switch designed for control-level networking and plant-wide communication. This unit operates on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e power supply and provides high-density connectivity with a total of \u003cstrong\u003e24 usable ports\u003c\/strong\u003e, including copper RJ45 and fiber optic SFP interfaces. As a \u003cstrong\u003eLayer 3\u003c\/strong\u003e device, it supports routing functions for network segmentation. Its robust feature set includes integrated redundancy functions and native support as a \u003cstrong\u003ePROFINET IO Device\u003c\/strong\u003e, making it suitable for high-availability industrial automation systems.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eLayer 3 management with routing capabilities\u003c\/li\u003e\n\u003cli\u003eFunctions as a PROFINET IO Device for seamless TIA integration\u003c\/li\u003e\n\u003cli\u003eHigh port density with 24 total usable 10\/100\/1000 Mbit\/s ports\u003c\/li\u003e\n\u003cli\u003eFlexible connectivity with 8 combo ports (RJ45 or SFP)\u003c\/li\u003e\n\u003cli\u003eIntegrated redundancy functions for high network availability\u003c\/li\u003e\n\u003cli\u003eSupports standard office network features (RSTP, VLAN, IGMP)\u003c\/li\u003e\n\u003cli\u003eEquipped with an error signaling contact for diagnostics\u003c\/li\u003e\n\u003cli\u003eIncludes a C-PLUG in the scope of delivery for configuration backup and transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003ePlant-wide network backbones in manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eControl-level networking in process automation and control systems\u003c\/li\u003e\n\u003cli\u003eSegmentation of large industrial networks using routing\u003c\/li\u003e\n\u003cli\u003eIntegration of automation cells into the enterprise network\u003c\/li\u003e\n\u003cli\u003eHigh-availability and redundant network structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSCALANCE XR524-8C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6GK5524-8GS00-2AR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManaged Layer 3 IE Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRJ45 Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e24 x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSFP Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e8 x 100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCombo Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eTotal Usable Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIndustrial Protocol\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePROFINET IO Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSupported Office Features\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRSTP, VLAN, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e44.90 cm x 4.40 cm x 30.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e5A002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin (Estimate)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e50 cm x 40 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 15px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 15px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. De-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before accessing terminals or making connections. Failure to do so can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e1\u003c\/span\u003e\nEnsure the control cabinet is de-energized and verified to be in a zero-energy state before beginning installation.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e2\u003c\/span\u003e\nSecurely mount the switch into a standard 19-inch industrial rack or cabinet using the appropriate mounting hardware. Ensure adequate ventilation space around the unit.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e3\u003c\/span\u003e\nConnect the functional earth (FE) or protective earth (PE) terminal on the switch chassis to the cabinet's main grounding point using a low-impedance conductor.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e4\u003c\/span\u003e\nTerminate the 24 V DC power supply wiring to the designated power input terminals, observing correct polarity. Use appropriately sized conductors for the load.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e5\u003c\/span\u003e\nIf using configuration backup, insert the C-PLUG into its designated slot on the device.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e6\u003c\/span\u003e\nConnect network cables to the RJ45 ports and\/or insert SFP transceivers and connect fiber optic cables as required by the network design.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e7\u003c\/span\u003e\nOnce all connections are secure, close the cabinet, remove LOTO devices, and re-energize the system. Verify correct operation via the device status LEDs.\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716393169259,"sku":"6GK5524-8GS00-2AR2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5524-8gs00-2ar2-ntxiyfjksp4_d4711036-9d59-47de-99db-e75b1e239a16.jpg?v=1767081968"},{"product_id":"siemens-6gk5302-7gd00-2ga3-scalance-x302-7eec-managed-ie-switch","title":"Siemens 6GK5302-7GD00-2GA3 SCALANCE X302-7EEC Managed IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5302-7GD00-2GA3\u003c\/strong\u003e is a compact, managed Industrial Ethernet (IE) switch from the \u003cstrong\u003eSCALANCE X302-7EEC\u003c\/strong\u003e series. This device is engineered for industrial network applications, offering a versatile port configuration including two 10\/100\/1000 Mbit\/s RJ45 ports and seven 100 Mbit\/s LC Fiber Optic (FO) ports. It functions as a PROFINET IO device and incorporates network management capabilities, an integrated redundancy manager, and support for standard office features such as RSTP, VLAN, and IGMP. Diagnostic feedback is provided via LED indicators and an error signaling contact, with configuration options accessible through a select\/set pushbutton. Designed for robust industrial environments, the switch features a 24 V DC redundant power supply unit and conformal coating, with a C-plug included in the scope of delivery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Industrial Ethernet switch functionality\u003c\/li\u003e\n\u003cli\u003e2x 10\/100\/1000 Mbit\/s RJ45 ports\u003c\/li\u003e\n\u003cli\u003e7x 100 Mbit\/s LC Fiber Optic (FO) ports\u003c\/li\u003e\n\u003cli\u003ePROFINET IO device support\u003c\/li\u003e\n\u003cli\u003eIntegrated redundancy manager\u003c\/li\u003e\n\u003cli\u003eSupports office features (RSTP, VLAN, IGMP)\u003c\/li\u003e\n\u003cli\u003eLED diagnostics and error signaling contact\u003c\/li\u003e\n\u003cli\u003eSelect\/set pushbutton for configuration\u003c\/li\u003e\n\u003cli\u003e24 V DC redundant power supply capability\u003c\/li\u003e\n\u003cli\u003eConformal coating for environmental protection\u003c\/li\u003e\n\u003cli\u003eC-plug included for easy replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Ethernet networks requiring managed switching and diagnostic features.\u003c\/li\u003e\n\u003cli\u003eIntegration into PROFINET IO systems for data exchange and control.\u003c\/li\u003e\n\u003cli\u003eApplications demanding high availability through network redundancy.\u003c\/li\u003e\n\u003cli\u003eDeployment in environments where fiber optic communication is beneficial for extended distances or electrical isolation.\u003c\/li\u003e\n\u003cli\u003eUse in harsh industrial settings due to conformal coating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5302-7GD00-2GA3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE X302-7EEC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged IE Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFiber Optic Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e7x 100 Mbit\/s LC FO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC (redundant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSpecial Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO device, Redundancy Manager, Conformal Coating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e21.60 x 11.00 x 14.30 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.60 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRJ45 Ports:\u003c\/strong\u003e For standard Ethernet connections at 10\/100\/1000 Mbit\/s.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLC Fiber Optic Ports:\u003c\/strong\u003e For 100 Mbit\/s fiber optic Ethernet connections.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Supply Terminals:\u003c\/strong\u003e For redundant 24 V DC power input.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eError Signaling Contact:\u003c\/strong\u003e For external fault indication.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSelect\/Set Pushbutton:\u003c\/strong\u003e For local device configuration and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energization:\u003c\/strong\u003e Ensure all power to the installation area is disconnected before mounting or wiring the device.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the SCALANCE switch in a suitable industrial enclosure or on a DIN rail, ensuring adequate ventilation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC redundant power supply to the designated terminals, observing correct polarity. Utilize both inputs for redundancy where required.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a robust protective earth (PE) connection to the device's grounding terminal to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect RJ45 Ethernet cables to the respective ports. For fiber optic connections, use appropriate LC fiber optic cables, ensuring proper handling to prevent damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Perform initial configuration using the select\/set pushbutton or via network management tools to integrate the switch into the existing network infrastructure.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e After installation and power-up, verify LED diagnostics for correct operation and network status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716400509291,"sku":"6GK5302-7GD00-2GA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5302-7gd00-2ga3-tnxcmeve33q_5b02fef7-f295-4eea-aa26-c2cd6a3389a6.jpg?v=1767082074"},{"product_id":"siemens-6gk5324-4qg10-1ar2-scalance-xr324-4m-poe-managed-ie-switch","title":"Siemens 6GK5324-4QG10-1AR2 SCALANCE XR324-4M PoE Managed IE Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5324-4QG10-1AR2 is a SCALANCE XR324-4M PoE, a managed Industrial Ethernet switch designed for \u003cstrong\u003e19-inch rack mounting\u003c\/strong\u003e. This device provides extensive connectivity with a total of \u003cstrong\u003e16 fixed RJ45 ports\u003c\/strong\u003e, eight of which support \u003cstrong\u003ePower over Ethernet (PoE)\u003c\/strong\u003e, and four slots for optional 2-port media modules for fiber optic or additional electrical connections. It operates as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e and is powered by a \u003cstrong\u003e24 V DC\u003c\/strong\u003e supply. Diagnostics are facilitated through front-facing LEDs, a select\/set pushbutton, and an error signaling contact for integration into plant monitoring systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eManaged Layer 2 switching capabilities\u003c\/li\u003e\n  \u003cli\u003eStandard 19-inch rack-mount form factor\u003c\/li\u003e\n  \u003cli\u003e8x 10\/100\/1000 Mbit\/s RJ45 ports with Power over Ethernet (PoE)\u003c\/li\u003e\n  \u003cli\u003e8x 10\/100\/1000 Mbit\/s standard RJ45 ports\u003c\/li\u003e\n  \u003cli\u003e4x slots for 2-port 10\/100\/1000 Mbit\/s media modules (electrical or optical)\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFINET IO device functionality\u003c\/li\u003e\n  \u003cli\u003eFront-panel LED diagnostics for status monitoring\u003c\/li\u003e\n  \u003cli\u003eError signaling contact for fault reporting\u003c\/li\u003e\n  \u003cli\u003eOperates on a 24 V DC nominal power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eMachine-level networking in manufacturing\u003c\/li\u003e\n  \u003cli\u003ePlant-wide network backbones\u003c\/li\u003e\n  \u003cli\u003eControl cabinet installations in process automation\u003c\/li\u003e\n  \u003cli\u003eIndustrial data centers and server rooms\u003c\/li\u003e\n  \u003cli\u003eApplications requiring PoE for devices like IP cameras or VOIP phones\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eXR324-4M PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5324-4QG10-1AR2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMounting\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e19-inch Rack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRJ45 Ports (with PoE)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e8x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRJ45 Ports (without PoE)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e8x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMedia Module Slots\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4 (for 2-port 10\/100\/1000 Mbit\/s modules)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIndustrial Protocol\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO Device\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e44.9 cm x 30.5 cm x 4.36 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout\/Tagout (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eEnsure the control cabinet or rack is fully de-energized and locked out before beginning work. Verify the absence of voltage.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eSecurely mount the SCALANCE switch into the 19-inch rack using the appropriate mounting hardware. Ensure adequate ventilation space around the unit.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eConnect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the switch chassis. This is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect the 24 V DC power supply wiring to the power input terminals, observing correct polarity. Use appropriately sized conductors for the load.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eConnect network devices using shielded Ethernet cables. Connect the error signaling contact wiring if required by the application.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eAfter all connections are secure, remove LOTO devices and re-energize the cabinet. Verify the switch powers on and that status LEDs indicate normal operation.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716424102251,"sku":"6GK5324-4QG10-1AR2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5324-4qg10-1ar2-yx1zgfo0s2c_aa11dfc9-2177-4bea-bade-da8b7f66e04b.jpg?v=1767082713"},{"product_id":"siemens-6gk5302-7gd00-3ea3-scalance-x302-7eec-managed-industrial-ethernet-switch","title":"Siemens 6GK5302-7GD00-3EA3 SCALANCE X302-7EEC Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n    \u003cp\u003eThe Siemens 6GK5302-7GD00-3EA3 is a compact, managed Industrial Ethernet switch from the SCALANCE X302-7EEC series. This device is engineered for industrial networking applications, providing a versatile port configuration with \u003cstrong\u003e2x 10\/100\/1000 Mbit\/s RJ45\u003c\/strong\u003e ports for high-speed connections and \u003cstrong\u003e7x 100 Mbit\/s LC fiber optic\u003c\/strong\u003e ports for long-distance or high-noise immunity links. It functions as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e, enabling seamless integration into Siemens automation environments. The switch supports a wide-range \u003cstrong\u003e100-240V AC\/DC power supply\u003c\/strong\u003e and includes an integrated redundancy manager to enhance network availability. A C-PLUG is included for straightforward device configuration backup and replacement.\u003c\/p\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eFeatures\u003c\/h3\u003e\n    \u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eManaged Layer 2 switch with a compact, robust design for industrial use.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntegrated redundancy manager for high network availability.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFunctions as a PROFINET IO device for direct automation system integration.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eSupports standard office and IT protocols including RSTP, VLAN, and IGMP.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eOn-device diagnostics via integrated LEDs and an error signaling contact.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIncludes a C-PLUG removable storage medium for configuration backup.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n    \u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eFactory automation and machine-level control networks.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eProcess control systems requiring redundant communication paths.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eConnecting distributed I\/O and control devices over long distances using fiber optics.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em;\"\u003e■\u003c\/span\u003eIntegration into PROFINET-based automation architectures.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto;\"\u003e\n        \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n            \u003cthead\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                    \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n                \u003c\/tr\u003e\n            \u003c\/thead\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5302-7GD00-3EA3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE X302-7EEC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e100-240 V AC\/DC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRJ45 Ports\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eFiber Optic Ports\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e7x 100 Mbit\/s LC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManagement Features\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO Device, Network Management, RSTP, VLAN, IGMP\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRedundancy\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntegrated Redundancy Manager\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2.30 kg\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e21.6 cm x 11.0 cm x 14.3 cm\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85176200\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n                    \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5A002\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n    \u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n        \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: HAZARD OF ELECTRIC SHOCK\u003c\/p\u003e\n        \u003cp style=\"margin-bottom: 0;\"\u003eDisconnect all power sources before installation or maintenance. This equipment is intended for use by qualified personnel only. Failure to de-energize the system can result in severe injury or death.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003col style=\"padding-left: 20px;\"\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e1\u003c\/span\u003e\n            Ensure the control cabinet is de-energized and locked out according to safety procedures. Verify the absence of voltage.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e2\u003c\/span\u003e\n            Mount the switch securely onto a standard 35mm DIN rail within the enclosure, ensuring adequate clearance for ventilation and cable access.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e3\u003c\/span\u003e\n            Connect a protective earth (PE) conductor to the designated grounding terminal on the switch chassis. A low-impedance ground connection is essential for safety and noise immunity.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e4\u003c\/span\u003e\n            Terminate the 100-240V AC\/DC power supply wiring to the correct terminals, observing polarity if applicable for DC sources.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e5\u003c\/span\u003e\n            Connect the RJ45 and LC fiber optic network cables. Ensure fiber optic connectors are clean before insertion and observe minimum bend radius requirements for all cables.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e6\u003c\/span\u003e\n            Insert the C-PLUG into its designated slot if using it for configuration storage.\n        \u003c\/li\u003e\n        \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n            \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; flex-shrink: 0; margin-right: 10px;\"\u003e7\u003c\/span\u003e\n            After closing the cabinet and removing safety locks, re-energize the system. Verify the switch's status LEDs for correct power-up and network link activity.\n        \u003c\/li\u003e\n    \u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716504187243,"sku":"6GK5302-7GD00-3EA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5302-7gd00-3ea3-snvk2jdfvsg_766ba33e-fdea-418c-85c3-2078b001fdfb.jpg?v=1767083608"},{"product_id":"siemens-6gk1611-0ta01-0ax0-simatic-net-communication-module","title":"Siemens 6GK1611-0TA01-0AX0 SIMATIC NET Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003eSiemens 6GK1611-0TA01-0AX0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC NET Communication Module\u003c\/strong\u003e. According to the provided description, this unit functions as a \u003cstrong\u003eSIMATIC HMI, MOBIC T8 G,E,F,S,I Rugged Mobile Internet Pad\u003c\/strong\u003e. It is designed for industrial applications, featuring control via a touch panel and offering internal Ethernet connectivity. Optional radio connectivity is available via a PCMCIA slot. The device operates with an internal Windows CE.NET operating system (G,E,F,S,I versions) and includes R software with a single license, classified as Class B. The package comes complete with a battery, power unit, EU\/UK US mains cable, pen, carrying belt, RS232 cable, and a manual on CD (available in German, English, French, Spanish, Italian, and Chinese).\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControllable via touch panel\u003c\/li\u003e\n\u003cli\u003eInternal Ethernet connectivity\u003c\/li\u003e\n\u003cli\u003eOptional radio connectivity via PCMCIA\u003c\/li\u003e\n\u003cli\u003eInternal Windows CE.NET operating system (G,E,F,S,I versions)\u003c\/li\u003e\n\u003cli\u003eR software, single license, Class B for industrial application\u003c\/li\u003e\n\u003cli\u003eIncludes battery and power unit\u003c\/li\u003e\n\u003cli\u003eSupplied with EU\/UK US mains cable, pen, carrying belt, and RS232 cable\u003c\/li\u003e\n\u003cli\u003eManual on CD (GER, E, F, S, I, CHIN)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe 6GK1611-0TA01-0AX0 is suitable for various industrial applications requiring a rugged, mobile human-machine interface or communication device. Potential uses include mobile data acquisition, on-site diagnostics, portable control interfaces, and remote monitoring in harsh industrial environments where portability and robust connectivity are essential.\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eSiemens\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eBrand\u003c\/td\u003e\n    \u003ctd\u003eSiemens\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRange\u003c\/td\u003e\n    \u003ctd\u003eSimatic S5\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSubrange\u003c\/td\u003e\n    \u003ctd\u003eNET\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eType of Product\u003c\/td\u003e\n    \u003ctd\u003eCommunication modules\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePLM Product Phase\u003c\/td\u003e\n    \u003ctd\u003eObsolete\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n    \u003ctd\u003e17.40 x 15.50 x 6.80 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eShipping Weight\u003c\/td\u003e\n    \u003ctd\u003e0.57 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCommodity Code\u003c\/td\u003e\n    \u003ctd\u003e85389091\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n    \u003ctd\u003eN\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInternal Ethernet port\u003c\/li\u003e\n\u003cli\u003ePCMCIA slot for optional radio module\u003c\/li\u003e\n\u003cli\u003eRS232 port (cable included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the supplied power unit to the device and an appropriate EU\/UK US mains outlet. Ensure the battery is charged for mobile operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePCMCIA Module Installation (Optional):\u003c\/strong\u003e If utilizing radio communication, carefully insert the compatible PCMCIA radio module into the designated slot. Refer to the module's specific instructions for proper seating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS232 Connection:\u003c\/strong\u003e Use the provided RS232 cable to connect the device to compatible serial equipment. Ensure correct pin assignment and secure connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e For wired network access, connect a standard Ethernet cable to the internal Ethernet port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e While rugged, ensure the device is operated within its specified environmental limits to prevent damage. Avoid extreme temperatures, excessive moisture, or direct impact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTouch Panel Operation:\u003c\/strong\u003e Utilize the included pen or a clean finger for precise interaction with the touch panel interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716517228907,"sku":"6GK1611-0TA01-0AX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1611-0ta01-0ax0-1vw1myqrpyv_e34864ec-2e9e-43a1-9ec2-9c507335ef37.jpg?v=1767083895"},{"product_id":"siemens-6gk5408-8gr00-2am2-scalance-xm408-8c-managed-modular-ie-switch","title":"Siemens 6GK5408-8GR00-2AM2 SCALANCE XM408-8C Managed Modular IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6GK5408-8GR00-2AM2\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE XM408-8C\u003c\/strong\u003e managed modular Industrial Ethernet (IE) switch designed for flexible network architectures. This module features a combination of 8x 10\/100\/1000 Mbit\/s RJ45 ports and 8x 100\/1000 Mbit\/s SFP ports, configured as 8 combo ports, allowing 8 ports to be utilized simultaneously. It is expandable to a total of 24 electrical or optical ports, providing scalability for growing industrial networks. The 6GK5408-8GR00-2AM2 supports DIN rail or S7 mounting and functions as a PROFINET IO device, integrating seamlessly into automation systems. It incorporates redundancy functions and standard office features such as RSTP, VLAN, and IGMP, with integrated Layer 3 capabilities for advanced network management. A C-plug is included in the scope of delivery.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged modular Industrial Ethernet switch\u003c\/li\u003e\n\u003cli\u003e8x 10\/100\/1000 Mbit\/s RJ45 ports\u003c\/li\u003e\n\u003cli\u003e8x 100\/1000 Mbit\/s SFP ports (8 combo ports, 8 usable)\u003c\/li\u003e\n\u003cli\u003eExpandable to 24 electrical or optical ports\u003c\/li\u003e\n\u003cli\u003eSupports DIN rail and S7 mounting\u003c\/li\u003e\n\u003cli\u003eFunctions as a PROFINET IO device\u003c\/li\u003e\n\u003cli\u003eIntegrated Layer 3 capabilities\u003c\/li\u003e\n\u003cli\u003eRedundancy functions for high availability\u003c\/li\u003e\n\u003cli\u003eSupports office features including RSTP, VLAN, and IGMP\u003c\/li\u003e\n\u003cli\u003eC-plug included for configuration data backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial network infrastructure for PROFINET environments\u003c\/li\u003e\n\u003cli\u003eMachine and plant networking requiring high port density and flexibility\u003c\/li\u003e\n\u003cli\u003eIntegration into existing automation systems via PROFINET IO\u003c\/li\u003e\n\u003cli\u003eApplications demanding network redundancy and advanced management features\u003c\/li\u003e\n\u003cli\u003eData communication in manufacturing, process automation, and energy sectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged Modular IE Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5408-8GR00-2AM2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE XM408-8C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSFP Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8x 100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCombo Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 (8 usable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpandability\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUp to 24 ports (electrical or optical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDIN rail \/ S7 mounting rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO device\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundancy functions, RSTP, VLAN, IGMP, Layer 3 integrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eC-plug\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e14.00 x 12.50 x 14.70 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3.60 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and connected devices is completely de-energized before beginning installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the SCALANCE XM408-8C module onto a standard DIN rail or S7 mounting rail in a suitable industrial enclosure. Ensure adequate space for ventilation and cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the power supply according to the module's specifications, observing correct polarity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Connections:\u003c\/strong\u003e Connect RJ45 Ethernet cables to the 10\/100\/1000 Mbit\/s ports as required. For fiber optic connections, insert appropriate 100\/1000 Mbit\/s SFP transceivers into the designated SFP slots and connect fiber optic cables.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-plug Insertion:\u003c\/strong\u003e Insert the included C-plug into its designated slot on the module. The C-plug stores configuration data and facilitates device replacement without re-configuration.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFINET Integration:\u003c\/strong\u003e Configure the module as a PROFINET IO device within the engineering software of the automation system.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding of the module and the enclosure to minimize electromagnetic interference and ensure operational safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables neatly and securely, avoiding sharp bends and ensuring they do not obstruct cooling airflow. Separate power and signal cables to prevent interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Re-energization:\u003c\/strong\u003e After all connections are verified, re-energize the system and confirm proper module operation through diagnostic indicators.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716575621483,"sku":"6GK5408-8GR00-2AM2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5408-8gr00-2am2-u4c12c4dq04_dfdbd0e5-28dd-4f84-8c0b-7391cc9cb92f.jpg?v=1767086076"},{"product_id":"siemens-6gk5308-2qg10-2aa2-scalance-x308-2m-poe-managed-industrial-ethernet-switch","title":"Siemens 6GK5308-2QG10-2AA2 SCALANCE X308-2M PoE Managed Industrial Ethernet Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5308-2QG10-2AA2\u003c\/strong\u003e is a SCALANCE X308-2M PoE managed Industrial Ethernet switch, designed for compact industrial network applications. This module features 4x 10\/100\/1000 Mbit\/s RJ45 electrical ports with Power over Ethernet (PoE) capability, alongside 2x 100\/1000 Mbit\/s slots for 2-port media modules, supporting both electrical and optical connections. It includes LED diagnostics and error signaling, a select\/set button for configuration, and functions as a PROFINET IO device. The switch integrates network management capabilities, an embedded redundancy manager, and supports various office features such as RSTP, VLAN, and IGMP. A C-plug is included in the scope of delivery for convenient setup.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManaged Industrial Ethernet Switch\u003c\/li\u003e\n  \u003cli\u003e4x 10\/100\/1000 Mbit\/s RJ45 electrical ports with Power over Ethernet (PoE)\u003c\/li\u003e\n  \u003cli\u003e2x 100\/1000 Mbit\/s slots for 2-port media modules (electrical or optical)\u003c\/li\u003e\n  \u003cli\u003eLED diagnostics and error signaling contact\u003c\/li\u003e\n  \u003cli\u003eSelect\/set button for local configuration\u003c\/li\u003e\n  \u003cli\u003ePROFINET IO device functionality\u003c\/li\u003e\n  \u003cli\u003eIntegrated network management\u003c\/li\u003e\n  \u003cli\u003eBuilt-in redundancy manager\u003c\/li\u003e\n  \u003cli\u003eSupports office features including RSTP, VLAN, and IGMP\u003c\/li\u003e\n  \u003cli\u003eC-plug included in delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial network infrastructure\u003c\/li\u003e\n  \u003cli\u003ePROFINET-based automation systems\u003c\/li\u003e\n  \u003cli\u003eData communication with integrated Power over Ethernet (PoE) for connected devices\u003c\/li\u003e\n  \u003cli\u003eRedundant network configurations in industrial environments\u003c\/li\u003e\n  \u003cli\u003eIntegration of diverse media types (electrical and optical) within a single network segment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12.00 x 12.40 x 12.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.90 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85389091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRJ45 Ports:\u003c\/strong\u003e 4x 10\/100\/1000 Mbit\/s, electrical, with Power over Ethernet (PoE)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMedia Module Slots:\u003c\/strong\u003e 2x for 2-port media modules, supporting 100\/1000 Mbit\/s electrical or optical connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and connected devices is completely de-energized before beginning installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the SCALANCE X308-2M PoE switch in a suitable industrial enclosure or on a DIN rail, ensuring adequate ventilation and clearance for cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the power supply according to the module's specifications, observing correct polarity and grounding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Connect Ethernet cables to the RJ45 ports for network communication and PoE-powered devices. Use appropriate industrial-grade cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMedia Module Installation:\u003c\/strong\u003e If optical or additional electrical connections are required, insert the compatible 2-port media modules into the designated slots.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper ground connection for the module to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eC-plug Configuration:\u003c\/strong\u003e Utilize the included C-plug for initial configuration or to restore settings as required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Verification:\u003c\/strong\u003e After installation, re-energize the system and verify proper operation through LED diagnostics and network connectivity tests.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716663112043,"sku":"6GK5308-2QG10-2AA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5308-2qg10-2aa2-bjm1ujnnyld_e3067c4d-06fd-487d-bd31-5fb9d63f0dc0.jpg?v=1767087523"},{"product_id":"siemens-6gk5307-3bl10-2aa3-scalance-x307-3-managed-industrial-ethernet-switch","title":"Siemens 6GK5307-3BL10-2AA3 SCALANCE X307-3 Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis device is a Siemens 6GK5307-3BL10-2AA3, a SCALANCE X307-3 series managed Industrial Ethernet switch designed for robust industrial networking applications. It provides a total of \u003cstrong\u003e10 ports\u003c\/strong\u003e, including \u003cstrong\u003e7x 10\/100 Mbit\/s RJ45\u003c\/strong\u003e copper ports and \u003cstrong\u003e3x 1000 Mbit\/s multimode (MM) SC\u003c\/strong\u003e fiber optic ports. Key features include integrated network management, functionality as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e, and an \u003cstrong\u003eintegrated redundancy manager\u003c\/strong\u003e to enhance network availability. The switch is equipped with LED diagnostics and an error signaling contact for status monitoring and fault detection. It supports standard office features such as RSTP, VLAN, and IGMP, and includes a C-PLUG for configuration backup and rapid device replacement.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eManaged Plus Industrial Ethernet (IE) switch functionality.\u003c\/li\u003e\n  \u003cli\u003eCombination of copper and fiber optic ports for flexible network design.\u003c\/li\u003e\n  \u003cli\u003eIntegrated redundancy manager for high-availability networks.\u003c\/li\u003e\n  \u003cli\u003eFunctions as a PROFINET IO device for seamless automation integration.\u003c\/li\u003e\n  \u003cli\u003eSupports RSTP, VLAN, and IGMP protocols.\u003c\/li\u003e\n  \u003cli\u003eOn-device diagnostics via LEDs and an error signaling contact.\u003c\/li\u003e\n  \u003cli\u003eIncludes a C-PLUG for storing configuration data.\u003c\/li\u003e\n  \u003cli\u003eEquipped with a select\/set button for on-site configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003ePlant-floor networking and control systems.\u003c\/li\u003e\n  \u003cli\u003eMachine-level data communication and automation cells.\u003c\/li\u003e\n  \u003cli\u003eIntegration of Ethernet devices into PROFINET networks.\u003c\/li\u003e\n  \u003cli\u003eImplementation of redundant ring or star network topologies.\u003c\/li\u003e\n  \u003cli\u003eConnecting remote segments of a plant via fiber optic links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE X307-3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5307-3BL10-2AA3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e7x 10\/100 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eFiber Optic Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e3x 1000 Mbit\/s, Multimode (MM) SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManagement Protocols\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO, RSTP, VLAN, IGMP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRedundancy\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntegrated Redundancy Manager\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDiagnostics\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eLED indicators, Error signaling contact\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eC-PLUG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1.40 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin (Estimated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12.00 cm x 12.30 cm x 12.50 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always adhere to local safety regulations and Lockout\/Tagout (LOTO) procedures.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, completely disconnect and lock out all power sources to the control cabinet or panel where the switch will be installed. Verify the absence of voltage.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount Device:\u003c\/strong\u003e Securely mount the SCALANCE switch onto a standard 35mm DIN rail within the enclosure. Ensure adequate clearance for ventilation and cable routing.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Grounding:\u003c\/strong\u003e Connect the functional earth (FE) terminal on the switch to the cabinet's equipotential bonding system using a low-impedance conductor to ensure proper grounding.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eTerminate Network Cables:\u003c\/strong\u003e Connect the RJ45 and SC fiber optic network cables to the corresponding ports. Ensure fiber optic connectors are clean before insertion and respect the minimum bend radius for all cables.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect the specified DC power supply to the power input terminals, observing correct polarity. Use appropriate wire gauges for the load and distance.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eSystem Energization and Verification:\u003c\/strong\u003e After confirming all connections are secure, remove LOTO devices and re-apply power to the system. Verify the switch powers on and check the status LEDs for normal operation and link activity.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716664095083,"sku":"6GK5307-3BL10-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5307-3bl10-2aa3-5ekoy5ntuxs_730ee40c-2887-48e0-b0a4-5d2555ce21ee.jpg?v=1767087558"},{"product_id":"siemens-6gk5308-2gg10-2aa2-scalance-x308-2m-managed-industrial-ethernet-switch","title":"Siemens 6GK5308-2GG10-2AA2 SCALANCE X308-2M Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5308-2GG10-2AA2 is a SCALANCE X308-2M compact managed Industrial Ethernet switch designed for machine-level networking and control cabinet installation. It provides a flexible port configuration with \u003cstrong\u003efour fixed 10\/100\/1000 Mbit\/s RJ45 ports\u003c\/strong\u003e and \u003cstrong\u003etwo slots for 2-port media modules\u003c\/strong\u003e, allowing for either electrical or optical connections at 100\/1000 Mbit\/s. As a PROFINET IO device with an integrated redundancy manager, this switch ensures high network availability and seamless integration into Siemens automation environments. The unit includes a C-PLUG in the scope of delivery for simple configuration backup and device replacement.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eManaged Layer 2 switching capabilities for network control.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eIntegrated redundancy manager to enhance network uptime.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eFunctions as a PROFINET IO device for diagnostics and system integration.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eSupports standard office IT protocols including RSTP, VLAN, and IGMP.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eEquipped with LED diagnostics, an error signaling contact, and a select\/set button for on-site management.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eIncludes a C-PLUG removable memory module for configuration storage.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eFactory and plant automation networks requiring high availability.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eMachine-level data aggregation and communication.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eIntegration of PROFINET-enabled devices into a structured Ethernet network.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cspan style=\"color: #2b6cb0; margin-right: 10px; font-size: 1.2em; line-height: 1;\"\u003e■\u003c\/span\u003e\n    \u003cspan\u003eControl systems requiring network segmentation via VLANs.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 400px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eProduct Identification\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eSCALANCE X-300\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eSCALANCE X308-2M\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e6GK5308-2GG10-2AA2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eInterfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eElectrical Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e4 x RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eElectrical Port Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e10\/100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eMedia Module Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e2 (for 2-port media modules, electrical or optical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eMedia Module Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e100\/1000 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eFunctionality\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eSupported Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003ePROFINET IO, RSTP, VLAN, IGMP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eC-PLUG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px 8px; background-color: #f7fafc; font-weight: 600;\"\u003eLogistics and Compliance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e0.90 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e12.0 cm x 12.4 cm x 12.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 8px 10px 24px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px 16px; background-color: #fff5f5; border-left: 4px solid #c53030; margin: 16px 0;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before installation or maintenance to prevent electric shock or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize Panel:\u003c\/strong\u003e Verify the control cabinet is completely de-energized and follow all applicable Lockout\/Tagout (LOTO) procedures before beginning work.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount Switch:\u003c\/strong\u003e Securely mount the SCALANCE switch onto a standard 35mm DIN rail within the enclosure, ensuring adequate clearance for ventilation and cable access.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Functional Ground:\u003c\/strong\u003e Connect the functional earth (FE) terminal on the switch to the cabinet's equipotential bonding rail using a low-impedance conductor.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power Supply:\u003c\/strong\u003e Connect the specified DC power source to the power supply terminal block, observing correct polarity. If redundant power supplies are used, connect both.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Network Cables:\u003c\/strong\u003e Connect shielded Ethernet cables to the RJ45 ports. If using media modules, install them into the slots and connect the corresponding cables. Ensure proper cable routing and strain relief.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower On and Verify:\u003c\/strong\u003e After ensuring all connections are secure, re-energize the cabinet. Observe the device LEDs to confirm power status, network link, and activity.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716664947051,"sku":"6GK5308-2GG10-2AA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5308-2gg10-2aa2-ulotuq2hmpx_57bd92f6-369e-4405-bdb0-927fbeadaf85.jpg?v=1767087587"},{"product_id":"siemens-6gk5308-2fl10-2aa3-scalance-x308-2-managed-industrial-ethernet-switch","title":"Siemens 6GK5308-2FL10-2AA3 SCALANCE X308-2 Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5308-2FL10-2AA3 is a SCALANCE X308-2 series managed plus Industrial Ethernet switch, engineered for reliable network management in demanding automation systems. This device provides a versatile port configuration with \u003cstrong\u003e2x 1000 Mbit\/s multimode SC fiber ports\u003c\/strong\u003e, \u003cstrong\u003e1x 10\/100\/1000 Mbit\/s RJ45 port\u003c\/strong\u003e, and \u003cstrong\u003e7x 10\/100 Mbit\/s RJ45 ports\u003c\/strong\u003e to support hybrid copper and fiber optic network infrastructures. It functions as a PROFINET IO device and includes an integrated redundancy manager to maintain high network availability. On-device diagnostics are facilitated by integrated LEDs and an error signaling contact with a select\/set button. The switch supports key office and IT features, including RSTP, VLAN, and IGMP, for advanced network segmentation and traffic control. A C-PLUG is included for simplified device replacement and commissioning.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eManaged Plus Industrial Ethernet (IE) switch functionality.\u003c\/li\u003e\n  \u003cli\u003ePROFINET IO device for seamless integration into Siemens automation environments.\u003c\/li\u003e\n  \u003cli\u003eIntegrated redundancy manager for enhanced network reliability.\u003c\/li\u003e\n  \u003cli\u003eOnboard LED diagnostics and error signaling contact for status monitoring.\u003c\/li\u003e\n  \u003cli\u003eSupports office features such as RSTP, VLAN, and IGMP.\u003c\/li\u003e\n  \u003cli\u003eIncludes a C-PLUG configuration memory module in the scope of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003ePlant-wide networking in manufacturing and process industries.\u003c\/li\u003e\n  \u003cli\u003eMachine-level networks requiring high-speed fiber optic uplinks.\u003c\/li\u003e\n  \u003cli\u003eIntegration of Ethernet-based devices in PROFINET control systems.\u003c\/li\u003e\n  \u003cli\u003eControl cabinet installations for automation and motion control applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eSCALANCE X308-2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eSKU \/ Order Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e6GK5308-2FL10-2AA3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eFiber Optic Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e2x 1000 Mbit\/s Multimode (MM) SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eGigabit Ethernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e1x 10\/100\/1000 Mbit\/s RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eFast Ethernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e7x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eManagement Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePROFINET IO, RSTP, VLAN, IGMP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eDiagnostics\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eLEDs, Error Signaling Contact\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eC-PLUG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e1.40 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e12.00 x 12.30 x 12.50 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eEAR99\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. Disconnect and lock out all power sources before installation or maintenance. Work must be performed by qualified personnel only. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eMount the switch securely onto a standard 35mm DIN rail inside a suitable enclosure that protects against environmental contaminants and provides adequate ventilation. Ensure a solid mechanical connection.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eConnect the functional earth (FE) terminal to the local equipotential bonding system. A low-impedance ground connection is critical for noise immunity and safety.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eConnect the DC power supply to the designated power input terminals. Verify the voltage and polarity are correct before energizing the unit. Use appropriately sized conductors and secure them firmly in the terminals.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect network devices using shielded RJ45 cables for copper ports and appropriate multimode fiber optic cables for the SC ports. Ensure connectors are clean and fully seated. Route data cables separately from high-voltage power lines.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eAfter all connections are made, restore power to the cabinet and verify the device's status LEDs for correct operation, including power, link status, and network activity.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716665930091,"sku":"6GK5308-2FL10-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5308-2fl10-2aa3-sofqt3i3t1w_dae084d1-0bb2-4f9b-a577-b863f3e43904.jpg?v=1767087631"},{"product_id":"siemens-6gk5788-2gd00-0tb0-scalance-w788-2-m12-eec-iwlan-access-point","title":"Siemens 6GK5788-2GD00-0TB0 SCALANCE W788-2 M12 EEC IWLAN Access Point","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis Siemens 6GK5788-2GD00-0TB0 is an industrial wireless LAN (IWLAN) access point from the SCALANCE W788-2 M12 EEC series, specifically configured for operation within the USA. It is engineered for high-performance wireless communication in demanding industrial environments, featuring \u003cstrong\u003edual radios\u003c\/strong\u003e that support IEEE 802.11a\/b\/g\/h\/n standards and achieve gross data rates of up to \u003cstrong\u003e450 Mbit\/s per radio\u003c\/strong\u003e. The unit is housed in a rugged \u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e with M12 and N-CON connectors, ensuring reliable operation in environments with dust, water, and vibration. Power can be supplied via \u003cstrong\u003ePower over Ethernet (PoE)\u003c\/strong\u003e or a redundant \u003cstrong\u003e24 V DC\u003c\/strong\u003e input, providing installation flexibility.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eDual-radio operation on 2.4 GHz and 5 GHz frequency bands.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSupports IEEE 802.11a\/b\/g\/h\/n wireless standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eHigh data throughput with up to 450 Mbit\/s per radio.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eRugged IP65-rated enclosure with M12 connectors for harsh environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eWide operating temperature range from -40 to +70 degC.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eConformal coating for enhanced protection against humidity and corrosive elements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eFlexible power options with Power over Ethernet (PoE) and redundant 24 V DC input.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eCompliant with EN 50155 and EN 45545 railway standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSupports advanced iFeatures via an optional KEY-PLUG.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eRailway and public transportation systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eAutomated Guided Vehicles (AGVs) and mobile equipment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eOutdoor industrial networking and infrastructure monitoring.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eProcess automation in manufacturing plants and refineries.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eMachine-to-machine (M2M) communication in harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #1a365d;\"\u003eSpecification\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #1a365d;\"\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eProduct Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eIWLAN Access Point\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eWireless Radios\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eWireless Standards\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eFrequency Bands\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2.4 GHz \/ 5 GHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eData Transfer Rate (Gross)\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eUp to 450 Mbit\/s per radio\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eEthernet Port\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e1x M12 (A-coded), max. 1 Gbit\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eAntenna Ports\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e6x N-CON\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003ePower Supply\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eRedundant 24 V DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSupported\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eSecurity\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eWPA2\/802.11i\/e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eProtection Rating\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eIP65\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eOperating Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e-40 to +70 degC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eFeatures\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eConformal coating, iFeatures support via KEY-PLUG\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eCompliance\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eEN 50155, EN 45545\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eRegional Approval\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eFor operation in USA only\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eCountry of Origin\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003eShipping Weight\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e1.80 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-top: 1px solid #e2e8f0;\"\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold; color: #2d3748;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e27.9 x 25.4 x 17.8 cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0; color: #c53030; font-weight: bold;\"\u003eCRITICAL WARNING: RISK OF EQUIPMENT DAMAGE AND NON-COMPLIANCE\u003c\/p\u003e\n    \u003cp style=\"margin-top: 8px; margin-bottom: 0;\"\u003eThis device is certified for operation within the United States only. Installation or use outside the USA may violate local regulations. Always de-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before installation or maintenance to prevent electrical shock.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/span\u003e\n        \u003cstrong\u003eVerify Site and Approvals:\u003c\/strong\u003e Confirm the installation location is within the USA. Ensure the mounting surface is stable and can support the device's weight (1.80 kg) and any connected antennas and cabling.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/span\u003e\n        \u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before making any connections, ensure all related power sources (24 V DC and PoE network switches) are de-energized and locked out per established safety protocols.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/span\u003e\n        \u003cstrong\u003eMount the Device:\u003c\/strong\u003e Securely fasten the SCALANCE W788-2 unit to the designated mounting surface using appropriate hardware for the environment (e.g., vibration-resistant bolts).\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/span\u003e\n        \u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the device's functional earth\/grounding terminal to the main system or cabinet ground using a low-impedance conductor to ensure proper electrical safety and signal integrity.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e5\u003c\/span\u003e\n        \u003cstrong\u003eConnect Antennas:\u003c\/strong\u003e Attach the required antennas to the six N-CON ports. Ensure connections are tightened to the correct torque specification to maintain the IP65 rating.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e6\u003c\/span\u003e\n        \u003cstrong\u003eConnect Ethernet\/PoE:\u003c\/strong\u003e Using an industrial-grade M12 A-coded Ethernet cable, connect the device to the network. If using PoE, ensure the switch port provides the required power.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e7\u003c\/span\u003e\n        \u003cstrong\u003eConnect DC Power (If Used):\u003c\/strong\u003e If not using PoE, connect the redundant 24 V DC power supply to the designated M12 power connector, observing correct polarity.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e8\u003c\/span\u003e\n        \u003cstrong\u003eInstall Sealing Caps:\u003c\/strong\u003e To maintain the IP65 rating, install the provided M12 and N-CON sealing caps on all unused ports.\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; position: relative; padding-left: 40px; line-height: 1.5;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 28px; height: 28px; background-color: #2b6cb0; color: #fff; border-radius: 50%; font-weight: bold;\"\u003e9\u003c\/span\u003e\n        \u003cstrong\u003ePower On and Verify:\u003c\/strong\u003e Remove LOTO devices and apply power to the system. Observe the device's status LEDs to confirm correct startup, network connectivity, and radio operation.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716721275243,"sku":"6GK5788-2GD00-0TB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5788-2gd00-0tb0-xnikkso4bsf_ea9cbcbf-f499-4dbf-97b8-022c46b55b17.jpg?v=1767088340"},{"product_id":"siemens-6gk5213-3bf00-2ab2-scalance-xb213-3ld-managed-layer-2-ie-switch","title":"Siemens 6GK5213-3BF00-2AB2 SCALANCE XB213-3LD Managed Layer 2 IE Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5213-3BF00-2AB2 is a SCALANCE XB213-3LD managed Layer 2 Industrial Ethernet switch designed for reliable network segmentation and communication in automation environments. This unit provides a high-density port configuration with \u003cstrong\u003e13 copper RJ45 ports\u003c\/strong\u003e and \u003cstrong\u003e3 single-mode fiber optic SC ports\u003c\/strong\u003e for long-distance connections. It features a redundant power supply input to enhance system availability and includes a dedicated console port for direct device management. With default PROFINET settings and certification to \u003cstrong\u003eIEC 62443-4-2\u003c\/strong\u003e, this switch is optimized for integration into industrial control networks requiring robust performance and security.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eManaged Layer 2 switching capabilities\u003c\/li\u003e\n  \u003cli\u003e13 x 10\/100 Mbps RJ45 ports for copper-based connections\u003c\/li\u003e\n  \u003cli\u003e3 x Single-Mode (SM) fiber optic ports with SC connectors\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostics via front-panel LEDs\u003c\/li\u003e\n  \u003cli\u003eRedundant power supply input for increased operational reliability\u003c\/li\u003e\n  \u003cli\u003eStandard DIN rail mounting for easy cabinet installation\u003c\/li\u003e\n  \u003cli\u003eCertified according to IEC 62443-4-2 for industrial security\u003c\/li\u003e\n  \u003cli\u003ePre-configured with default PROFINET settings for simplified commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eFactory and manufacturing automation\u003c\/li\u003e\n  \u003cli\u003eProcess control networks (DCS, PLC)\u003c\/li\u003e\n  \u003cli\u003eMachine-level networking and data acquisition\u003c\/li\u003e\n  \u003cli\u003eTransportation and traffic control systems\u003c\/li\u003e\n  \u003cli\u003eInfrastructure monitoring and utilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSCALANCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e6GK5213-3BF00-2AB2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManaged Layer 2 IE Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e0 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMounting\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eStandard Rail\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eRedundant Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDefault Protocol Settings\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePROFINET\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSecurity Certification\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eIEC 62443-4-2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eActive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e12.0 cm x 10.9 cm x 11.7 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e0.28 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eInterface\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eDetails\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e13 x 10\/100 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eFiber Optic Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e3 x Single-Mode (SM) with SC connectors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManagement Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e1 x Console Port\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px 16px; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages can cause electric shock and burns. Disconnect, lock out, and tag out all power sources before installation or service. Work must be performed by qualified personnel only.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    De-energize the control cabinet and verify the absence of voltage before beginning work.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    Mount the switch securely onto a standard 35mm DIN rail inside the enclosure, ensuring proper orientation for ventilation.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    Connect a low-impedance protective earth (PE) or functional ground conductor to the designated terminal on the switch chassis.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    Terminate the RJ45 and fiber optic SC network cables. Ensure fiber optic connectors are clean before insertion.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    Connect the primary and, if used, redundant power supply conductors to the power terminal block, observing correct polarity.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    Re-energize the system and verify the status of the power and diagnostic LEDs on the front panel of the switch.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716729500011,"sku":"6GK5213-3BF00-2AB2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5213-3bf00-2ab2-4mtecddwpgq_68849845-b49b-4d2b-9677-909606412197.jpg?v=1767088419"},{"product_id":"siemens-6gk5216-4gs00-2ac2-scalance-xc216-4c-g-managed-layer-2-ie-switch","title":"Siemens 6GK5216-4GS00-2AC2 SCALANCE XC216-4C G Managed Layer 2 IE Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5216-4GS00-2AC2 is a SCALANCE XC216-4C G managed Layer 2 Industrial Ethernet switch designed for robust performance in demanding automation environments. This full Gigabit switch provides a high-density port configuration with \u003cstrong\u003e12 RJ45 ports\u003c\/strong\u003e and \u003cstrong\u003e4 flexible combo ports\u003c\/strong\u003e, suitable for either SFP fiber optic or copper RJ45 connections. It supports critical industrial protocols like \u003cstrong\u003ePROFINET IO\u003c\/strong\u003e and is \u003cstrong\u003eEthernet\/IP compliant\u003c\/strong\u003e, ensuring seamless integration into modern control systems. With features such as a redundant power supply, an extended operating temperature range, and a slot for a C-PLUG configuration memory module, this switch is engineered for high network availability and simplified device replacement.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eFull Gigabit performance across all ports for high-speed data transfer.\u003c\/li\u003e\n    \u003cli\u003eManaged Layer 2 switching with office features including RSTP and VLANs.\u003c\/li\u003e\n    \u003cli\u003ePROFINET IO device functionality for integration into Siemens automation networks.\u003c\/li\u003e\n    \u003cli\u003eEthernet\/IP compliant for interoperability with Rockwell\/Allen-Bradley systems.\u003c\/li\u003e\n    \u003cli\u003eExtended operating temperature range from -40 to +70 degC.\u003c\/li\u003e\n    \u003cli\u003eRedundant power supply input for increased operational reliability.\u003c\/li\u003e\n    \u003cli\u003eC-PLUG slot for easy device replacement without reprogramming.\u003c\/li\u003e\n    \u003cli\u003eCertified to IEC 62443-4-2 for industrial network security.\u003c\/li\u003e\n    \u003cli\u003eOnboard diagnostics LED for at-a-glance status monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eFactory automation and plant-floor control networks.\u003c\/li\u003e\n    \u003cli\u003eProcess control systems requiring high network availability.\u003c\/li\u003e\n    \u003cli\u003eInfrastructure projects such as traffic control and utility management.\u003c\/li\u003e\n    \u003cli\u003eMachine-to-machine (M2M) communication links.\u003c\/li\u003e\n    \u003cli\u003eApplications in harsh environments with wide temperature fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eXC216-4C G\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5216-4GS00-2AC2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Layer 2 Industrial Ethernet Switch\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRJ45 Ports\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12 x 10\/100\/1000 Mbps\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCombo Ports\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4 x 1000 Mbps (configurable as SFP or RJ45)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eConsole Port\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIndustrial Protocols\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO Device, Ethernet\/IP Compliant\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRedundant Input\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e-40 to +70 degC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMounting Options\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDIN Rail, S7 Mounting Rail, Wall Mount\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSecurity Certification\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIEC 62443-4-2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.52 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85176200\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEAR99\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e20 x 15 x 10 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Installation must be performed by qualified personnel only. De-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before commencing any installation or maintenance tasks. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003eDe-energize the control cabinet and verify the absence of voltage before handling the device.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003eSecurely mount the switch onto a standard DIN rail, S7 rail, or a flat panel\/wall surface using the appropriate mounting points. Ensure adequate clearance for ventilation and cable access.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003eConnect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the switch chassis. This is essential for safety and EMC performance.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003eConnect the primary and, if used, redundant DC power supply lines to the power input terminals, observing correct polarity.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003eTerminate shielded Ethernet cables to the RJ45 ports. Ensure proper shield grounding at the cable gland or connector backshell to minimize noise interference.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n        \u003cspan\u003eIf using fiber optic connections, insert the appropriate SFP transceivers into the combo port cages before connecting fiber optic patch cords.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n        \u003cspan\u003eInsert a C-PLUG memory module (if available) into the designated slot to enable automatic configuration backup and restore.\u003c\/span\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e8\u003c\/span\u003e\n        \u003cspan\u003eAfter all connections are secure, re-energize the cabinet and verify the status LEDs on the switch for power, link activity, and fault indications.\u003c\/span\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716748472683,"sku":"6GK5216-4GS00-2AC2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5216-4gs00-2ac2-wgmwpiu14j4_569ad2db-4fb5-49f9-9e7c-f745c77d3336.jpg?v=1767088634"},{"product_id":"siemens-6gk5786-2fc00-0ab0-scalance-w786-2-iwlan-access-point","title":"Siemens 6GK5786-2FC00-0AB0 SCALANCE W786-2 IWLAN Access Point","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5786-2FC00-0AB0\u003c\/strong\u003e is an IWLAN Access Point from the \u003cstrong\u003eSCALANCE W786-2 RJ45\u003c\/strong\u003e series, designed for robust industrial wireless communication. This device features two independent radios and six R-SMA antenna ports, supporting iFeatures via a key plug. It operates on IEEE 802.11a\/b\/g\/h\/n wireless standards across both 2.4 GHz and 5 GHz frequency bands, delivering a gross data rate of 450 Mbit\/s per radio. Connectivity includes one RJ45 port with speeds up to 1 Gbit\/s and support for Power over Ethernet (PoE). Power options include redundant 24 V DC via a terminal block, or 110-230 V AC when used with the PS791-2AC power supply. With an IP65 protection rating and an operating temperature range of -40 degC to +60 degC, it is suitable for demanding industrial environments. Security protocols such as WPA2, 802.11i, and 802.11e are supported, and the unit is certified with ID EAPN-W2-RJ-E3. It includes an MPCIE-R1-ABGN-U3 module and is designed for operation in regions like the USA.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIWLAN Access Point functionality\u003c\/li\u003e\n  \u003cli\u003eSCALANCE W786-2 RJ45 series\u003c\/li\u003e\n  \u003cli\u003eDual radio operation for enhanced capacity\u003c\/li\u003e\n  \u003cli\u003eSix R-SMA antenna ports for flexible antenna configuration\u003c\/li\u003e\n  \u003cli\u003eiFeatures support via key plug\u003c\/li\u003e\n  \u003cli\u003eSupports IEEE 802.11a\/b\/g\/h\/n wireless standards\u003c\/li\u003e\n  \u003cli\u003eOperates on 2.4 GHz and 5 GHz frequency bands\u003c\/li\u003e\n  \u003cli\u003eGross data rate of 450 Mbit\/s per radio\u003c\/li\u003e\n  \u003cli\u003eOne RJ45 Ethernet port with up to 1 Gbit\/s speed\u003c\/li\u003e\n  \u003cli\u003eIntegrated Power over Ethernet (PoE) support\u003c\/li\u003e\n  \u003cli\u003eRedundant 24 V DC power supply capability via terminal block\u003c\/li\u003e\n  \u003cli\u003e110-230 V AC power supply option via external PS791-2AC\u003c\/li\u003e\n  \u003cli\u003eIP65 protection rating for harsh environments\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range: -40 degC to +60 degC\u003c\/li\u003e\n  \u003cli\u003eWPA2\/802.11i\/e security protocols\u003c\/li\u003e\n  \u003cli\u003eIncludes MPCIE-R1-ABGN-U3 module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5786-2FC00-0AB0 IWLAN Access Point is suitable for a wide range of industrial applications requiring robust and reliable wireless communication. Typical deployments include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation and control systems\u003c\/li\u003e\n  \u003cli\u003eWireless networking in harsh factory environments\u003c\/li\u003e\n  \u003cli\u003eOutdoor and semi-outdoor installations due to IP65 rating\u003c\/li\u003e\n  \u003cli\u003eLogistics and material handling systems\u003c\/li\u003e\n  \u003cli\u003eMobile equipment communication\u003c\/li\u003e\n  \u003cli\u003eProcess industry applications requiring secure and stable wireless links\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWireless Standards\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFrequency Bands\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.4 GHz, 5 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNumber of Radios\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAntenna Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6 x R-SMA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGross Data Rate (per radio)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e450 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Speed\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax. 1 Gbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply (DC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundant 24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply (AC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110-230 V AC (via PS791-2AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-40 degC to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSecurity Protocols\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWPA2\/802.11i\/e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCertification ID\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEAPN-W2-RJ-E3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIncluded Module\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMPCIE-R1-ABGN-U3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e35.60 x 12.70 x 30.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.90 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAntenna Ports:\u003c\/strong\u003e 6 x R-SMA connectors for external antennas.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e 1 x RJ45 connector for wired network connection and Power over Ethernet (PoE).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Terminal block for redundant 24 V DC input.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug Slot:\u003c\/strong\u003e For iFeatures key plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area is disconnected before commencing work.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the access point in the desired location, considering its IP65 rating for environmental protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAntenna Connection:\u003c\/strong\u003e Connect appropriate R-SMA antennas to the six designated ports. Ensure proper torque to maintain weather sealing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection (DC):\u003c\/strong\u003e For 24 V DC operation, connect the redundant power supplies to the included terminal block, observing correct polarity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection (AC):\u003c\/strong\u003e If using 110-230 V AC, connect the external PS791-2AC power supply according to its instructions, then connect its output to the access point.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect the RJ45 Ethernet cable. If using PoE, ensure the connected switch or injector provides compliant PoE power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKey Plug Insertion:\u003c\/strong\u003e If iFeatures are required, insert the corresponding key plug into the designated slot.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the access point is properly grounded according to local electrical codes and Siemens guidelines to prevent electrical interference and ensure safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route all cables to minimize stress on connectors and maintain the IP65 rating where applicable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Up:\u003c\/strong\u003e Re-energize the system and verify operational status indicators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Configure the access point's wireless settings, security protocols, and network parameters as required for the application.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5786-2FC00-0AB0 carries the Certification ID \u003cstrong\u003eEAPN-W2-RJ-E3\u003c\/strong\u003e. Users must observe and comply with all national approvals and regulations pertinent to the installation and operation of wireless communication devices in their specific region.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716751651179,"sku":"6GK5786-2FC00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5786-2fc00-0ab0-fa1nxfm22ox_bbec0370-bb52-4219-b9b9-2e208862ce1b.jpg?v=1767088654"},{"product_id":"siemens-6gk5786-2fe00-0ab0-scalance-w786-2-sfp-iwlan-access-point","title":"Siemens 6GK5786-2FE00-0AB0 SCALANCE W786-2 SFP IWLAN Access Point","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6GK5786-2FE00-0AB0\u003c\/strong\u003e is an \u003cstrong\u003eIWLAN Access Point\u003c\/strong\u003e from the \u003cstrong\u003eSCALANCE W786-2 SFP\u003c\/strong\u003e series, designed for robust industrial wireless communication. This device features two independent radios and six R-SMA antenna ports, supporting iFeatures via a key plug. It operates on IEEE 802.11a\/b\/g\/h\/n standards across 2.4 GHz and 5 GHz frequency bands, delivering a gross data rate of 450 Mbit\/s per radio.\u003c\/p\u003e\n\u003cp\u003eConnectivity is provided by two SFP 1 Gbit\/s switches. The unit supports redundant 24 V DC power input via a terminal block and can also be powered by 110-230 V AC via an optional PS791-2AC adapter. With an IP65 protection rating, it is suitable for demanding environments, offering an operating temperature range of -40 degC to +60 degC (dependent on the SFP module used). It incorporates WPA2\/802.11i\/e security protocols and is identified with CERT ID EAPN-W2-SFP-E3, including an MPCIE-R1-ABGN-U3 module. Manuals for operation in the USA are provided on CD-ROM.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIWLAN Access Point (SCALANCE W786-2 SFP series)\u003c\/li\u003e\n  \u003cli\u003eDual radio design for enhanced performance\u003c\/li\u003e\n  \u003cli\u003e6 R-SMA antenna ports\u003c\/li\u003e\n  \u003cli\u003eiFeatures support via key plug\u003c\/li\u003e\n  \u003cli\u003eWireless standards: IEEE 802.11a\/b\/g\/h\/n\u003c\/li\u003e\n  \u003cli\u003eFrequency bands: 2.4 GHz and 5 GHz\u003c\/li\u003e\n  \u003cli\u003eGross data rate: 450 Mbit\/s per radio\u003c\/li\u003e\n  \u003cli\u003eIntegrated 2x SFP 1 Gbit\/s switches\u003c\/li\u003e\n  \u003cli\u003eRedundant 24 V DC power input via terminal block\u003c\/li\u003e\n  \u003cli\u003eOptional 110-230 V AC power via PS791-2AC\u003c\/li\u003e\n  \u003cli\u003eProtection rating: IP65\u003c\/li\u003e\n  \u003cli\u003eOperating temperature range: -40 degC to +60 degC (SFP dependent)\u003c\/li\u003e\n  \u003cli\u003eSecurity protocols: WPA2\/802.11i\/e\u003c\/li\u003e\n  \u003cli\u003eIncludes MPCIE-R1-ABGN-U3 module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial wireless local area networks (IWLAN)\u003c\/li\u003e\n  \u003cli\u003eHigh-speed data transmission in harsh industrial environments\u003c\/li\u003e\n  \u003cli\u003eSecure wireless communication for automation and control systems\u003c\/li\u003e\n  \u003cli\u003eDeployment in outdoor or dusty\/wet conditions requiring IP65 protection\u003c\/li\u003e\n  \u003cli\u003eApplications requiring redundant power supply for increased reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE W786-2 SFP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5786-2FE00-0AB0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIWLAN Access Point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRadios\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAntenna Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6 R-SMA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWireless Standards\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFrequency Bands\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.4 GHz, 5 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGross Data Rate (per radio)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e450 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x SFP 1 Gbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply (DC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundant 24 V DC (via terminal block)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply (AC)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110-230 V AC (via PS791-2AC, optional)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-40 degC to +60 degC (SFP dependent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSecurity Protocols\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWPA2, 802.11i\/e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCertification ID\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEAPN-W2-SFP-E3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIncluded Module\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMPCIE-R1-ABGN-U3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e27.90 x 10.20 x 33.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.10 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6x R-SMA antenna ports\u003c\/li\u003e\n  \u003cli\u003e2x SFP 1 Gbit\/s ports\u003c\/li\u003e\n  \u003cli\u003eTerminal block for 24 V DC power input\u003c\/li\u003e\n  \u003cli\u003ePlug slot for optional PS791-2AC AC power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area is disconnected and locked out before beginning any work.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the IWLAN Access Point in the desired location, ensuring the IP65 rating is maintained. Consider environmental factors such as temperature and potential physical impact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAntenna Connection:\u003c\/strong\u003e Connect up to six R-SMA antennas to the designated ports. Ensure connections are tight to maintain signal integrity and IP65 rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSFP Module Installation:\u003c\/strong\u003e Insert appropriate SFP 1 Gbit\/s modules into the two SFP slots. Connect fiber optic cables as required for network integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Power Wiring:\u003c\/strong\u003e Connect the redundant 24 V DC power supplies to the terminal block, observing correct polarity. Ensure proper wire gauges are used and connections are secure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Power Option:\u003c\/strong\u003e If using AC power, connect the PS791-2AC adapter to the dedicated plug slot and then to the AC mains supply (110-230 V AC).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the device is properly grounded according to local electrical codes and industrial standards to protect against electrical surges and ensure stable operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e After power-up, configure the access point according to network requirements, including wireless settings, security protocols (WPA2\/802.11i\/e), and iFeatures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNational Approvals:\u003c\/strong\u003e Verify that the installation and operation comply with all relevant national and regional wireless communication approvals and regulations, especially for operation in specific countries like the USA.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCERT ID: EAPN-W2-SFP-E3\u003c\/li\u003e\n  \u003cli\u003eDesigned for operation in the USA (observe national approvals)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716755190123,"sku":"6GK5786-2FE00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5786-2fe00-0ab0-sodumo1n5ya_8d580a88-cbe6-422e-aca3-aa4395076074.jpg?v=1767088719"},{"product_id":"siemens-6gk5324-0gg10-3ar2-scalance-xr324-12m-managed-industrial-ethernet-switch","title":"Siemens 6GK5324-0GG10-3AR2 SCALANCE XR324-12M Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis Siemens 6GK5324-0GG10-3AR2 is a SCALANCE XR324-12M managed Industrial Ethernet switch designed for high-density network applications. The unit is housed in a standard \u003cstrong\u003e19-inch rack-mountable\u003c\/strong\u003e chassis with front-facing ports for simplified access in control cabinets. It features 12 modular slots for 2-port media modules, allowing for flexible configurations of electrical or optical connections at speeds of \u003cstrong\u003e100\/1000 Mbit\/s\u003c\/strong\u003e. As a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e with an integrated redundancy manager, it ensures high availability and seamless integration into industrial automation environments. The switch operates on a \u003cstrong\u003e230 V AC power supply\u003c\/strong\u003e and includes a C-PLUG for straightforward device replacement and configuration backup.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003eManaged Industrial Ethernet (IE) switch functionality.\u003c\/li\u003e\n\u003cli\u003eStandard 19-inch rack-mount form factor.\u003c\/li\u003e\n\u003cli\u003eSupports up to 12 two-port media modules for electrical or optical connections.\u003c\/li\u003e\n\u003cli\u003eFunctions as a PROFINET IO device for automation networks.\u003c\/li\u003e\n\u003cli\u003eIntegrated redundancy manager for enhanced network reliability.\u003c\/li\u003e\n\u003cli\u003eSupports office features including RSTP, VLAN, and IGMP.\u003c\/li\u003e\n\u003cli\u003eOnboard LED diagnostics and an error signaling contact for status monitoring.\u003c\/li\u003e\n\u003cli\u003eIncludes a C-PLUG for configuration storage and transfer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003ePlant-wide industrial network backbones.\u003c\/li\u003e\n\u003cli\u003eHigh-density control cabinet and data center installations.\u003c\/li\u003e\n\u003cli\u003eAutomation networks requiring PROFINET integration.\u003c\/li\u003e\n\u003cli\u003eSystems demanding high network availability and media flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eXR324-12M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5324-0GG10-3AR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e19-inch Rack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModular Ports\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e12 slots for 2-port media modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePort Speed\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRSTP, VLAN, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIndustrial Protocol\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePLM Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e48.3 x 30.5 x 4.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6.80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5A002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px 16px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Installation must be performed by qualified personnel only. Failure to adhere to safety protocols, including Lockout\/Tagout (LOTO) procedures, can result in severe injury or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before installation, completely de-energize the control cabinet and verify the absence of voltage. Follow all site-specific LOTO procedures.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Securely mount the switch chassis into a standard 19-inch industrial rack using all four mounting points to ensure stability and proper grounding.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Connect the 230 V AC power supply to the designated terminals. Ensure wiring is correctly sized and connections are torqued to specification.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eInstall Media Modules:\u003c\/strong\u003e Insert the required electrical or optical 2-port media modules into the empty slots. Ensure each module is fully seated and secured.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Network Cables:\u003c\/strong\u003e Connect network cabling to the installed media modules. Maintain proper bend radius and secure cables to prevent strain on the connectors.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSystem Verification:\u003c\/strong\u003e Once all connections are made, remove LOTO devices and re-energize the cabinet. Verify power and status LEDs on the switch front panel for normal operation.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716758729067,"sku":"6GK5324-0GG10-3AR2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5324-0gg10-3ar2-pvohrelrkxh_7caa2729-f330-4897-9709-f9527053bd3b.jpg?v=1767088758"},{"product_id":"siemens-6gk5307-3bl00-2aa3-simatic-scalance-x307-3-managed-plus-ie-switch","title":"Siemens 6GK5307-3BL00-2AA3 SIMATIC SCALANCE X307-3 Managed Plus IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003eSiemens 6GK5307-3BL00-2AA3\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X307-3\u003c\/strong\u003e, managed plus Industrial Ethernet (IE) switch designed for robust industrial communication networks. This module features a versatile port configuration, including 3x 1000 Mbit\/s Multi-Mode (MM) SC ports and 7x 10\/100 Mbit\/s RJ45 ports, enabling flexible connectivity options. It incorporates LED diagnostics for status monitoring and an error signaling contact with a select\/set pushbutton for fault management. The \u003cstrong\u003e6GK5307-3BL00-2AA3\u003c\/strong\u003e functions as a PROFINET IO device and includes comprehensive network management capabilities, an integrated redundancy manager, and office features such as RSTP, VLAN, and IGMP to ensure reliable and efficient data flow. A C-plug is included in the scope of supply for convenient setup.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3x 1000 Mbit\/s Multi-Mode (MM) SC ports\u003c\/li\u003e\n\u003cli\u003e7x 10\/100 Mbit\/s RJ45 ports\u003c\/li\u003e\n\u003cli\u003eLED diagnostics for operational status\u003c\/li\u003e\n\u003cli\u003eError signaling contact with select\/set pushbutton\u003c\/li\u003e\n\u003cli\u003ePROFINET IO device functionality\u003c\/li\u003e\n\u003cli\u003eIntegrated network management\u003c\/li\u003e\n\u003cli\u003eIntegrated redundancy manager for high availability\u003c\/li\u003e\n\u003cli\u003eSupports office features including RSTP, VLAN, and IGMP\u003c\/li\u003e\n\u003cli\u003eC-plug included in scope of supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens 6GK5307-3BL00-2AA3 SCALANCE X307-3 Managed Plus IE Switch is suitable for a wide range of industrial applications requiring reliable and managed network communication, including:\n\u003cul\u003e\n\u003cli\u003eIndustrial automation systems and control networks\u003c\/li\u003e\n\u003cli\u003ePROFINET-based architectures\u003c\/li\u003e\n\u003cli\u003ePlant-wide data communication\u003c\/li\u003e\n\u003cli\u003eIntegration of office and industrial networks\u003c\/li\u003e\n\u003cli\u003eApplications requiring network redundancy and fault tolerance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged Plus IE Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE X307-3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5307-3BL00-2AA3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePort Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3x 1000 Mbit\/s MM SC, 7x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDiagnostics\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLED diagnostics, Error signaling contact with select\/set pushbutton\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIndustrial Protocol Support\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO device\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManagement Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork management, Integrated redundancy manager\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOffice Features\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRSTP, VLAN, IGMP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eC-plug\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12.00 x 12.30 x 12.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the switch securely on a DIN rail or panel in a suitable industrial enclosure, ensuring adequate ventilation and clearance for cabling.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the power supply according to the module's specifications. Ensure proper polarity and grounding to prevent electrical damage and ensure safe operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-Plug Installation:\u003c\/strong\u003e Insert the provided C-plug into its designated slot on the switch.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect the 10\/100 Mbit\/s RJ45 ports using standard Ethernet cables. For the 1000 Mbit\/s MM SC ports, use appropriate fiber optic cables. Ensure cables are properly routed and secured to prevent strain and interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a reliable protective earth (PE) connection for the device to minimize electromagnetic interference and ensure safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Once powered, configure the switch parameters (e.g., VLANs, redundancy settings, PROFINET IO device settings) via the network management interface as required by the application.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Verify all connections and configurations by performing functional tests to ensure proper network operation and communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716760695147,"sku":"6GK5307-3BL00-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5307-3bl00-2aa3-xq4t0u2owdo_cb374092-ec09-453d-b0ab-e2776578fbdf.jpg?v=1767088824"},{"product_id":"siemens-6gk5213-3bb00-2ab2-scalance-xb213-3-managed-layer-2-ie-switch","title":"Siemens 6GK5213-3BB00-2AB2 SCALANCE XB213-3 Managed Layer 2 IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6GK5213-3BB00-2AB2\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE XB213-3\u003c\/strong\u003e managed Layer 2 Industrial Ethernet switch designed for robust industrial network applications. This module features 13x 10\/100 Mbps RJ45 ports for copper connectivity and 3x multimode fiber optic ST ports for extended distance communication. It includes a console port for configuration and diagnostics LEDs for status monitoring. The switch supports a redundant power supply for enhanced operational reliability and is certified to \u003cstrong\u003eIEC 62443-4-2\u003c\/strong\u003e, ensuring compliance with cybersecurity standards for industrial automation and control systems. It operates within a temperature range of 0 degC to +60 degC and is designed for mounting onto a standard rail, supporting default PROFINET integration.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Layer 2 Industrial Ethernet switch\u003c\/li\u003e\n\u003cli\u003e13x 10\/100 Mbps RJ45 ports\u003c\/li\u003e\n\u003cli\u003e3x Multimode Fiber Optic (MM FO) ST ports\u003c\/li\u003e\n\u003cli\u003e1x Console port for configuration and diagnostics\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostics LED indicators\u003c\/li\u003e\n\u003cli\u003eSupports redundant power supply configurations\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2 certified for cybersecurity\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: 0 degC to +60 degC\u003c\/li\u003e\n\u003cli\u003eDesigned for standard rail mounting\u003c\/li\u003e\n\u003cli\u003eDefault PROFINET support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Ethernet networks requiring managed Layer 2 switching capabilities\u003c\/li\u003e\n\u003cli\u003eIntegration into PROFINET-based automation systems\u003c\/li\u003e\n\u003cli\u003eApplications demanding a combination of copper and fiber optic connectivity\u003c\/li\u003e\n\u003cli\u003eSystems requiring enhanced network reliability through redundant power supply support\u003c\/li\u003e\n\u003cli\u003eIndustrial control systems (ICS) where cybersecurity compliance (IEC 62443-4-2) is critical\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O and field device connectivity in harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eSiemens\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eBrand\u003c\/td\u003e\n    \u003ctd\u003eSiemens\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRange\u003c\/td\u003e\n    \u003ctd\u003eSCALANCE\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eType of Product\u003c\/td\u003e\n    \u003ctd\u003eManaged Layer 2 IE Switch\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Phase\u003c\/td\u003e\n    \u003ctd\u003eActive\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNumber of RJ45 Ports\u003c\/td\u003e\n    \u003ctd\u003e13\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRJ45 Port Speed\u003c\/td\u003e\n    \u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNumber of Fiber Optic Ports\u003c\/td\u003e\n    \u003ctd\u003e3\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eFiber Optic Port Type\u003c\/td\u003e\n    \u003ctd\u003eMultimode (MM) FO ST\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eConsole Port\u003c\/td\u003e\n    \u003ctd\u003e1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePower Supply\u003c\/td\u003e\n    \u003ctd\u003eRedundant (supported)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMounting\u003c\/td\u003e\n    \u003ctd\u003eStandard rail\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCertification\u003c\/td\u003e\n    \u003ctd\u003eIEC 62443-4-2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProtocol Support\u003c\/td\u003e\n    \u003ctd\u003ePROFINET (default)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n    \u003ctd\u003e12.00 x 10.90 x 11.70 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eShipping Weight\u003c\/td\u003e\n    \u003ctd\u003e0.28 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCommodity Code\u003c\/td\u003e\n    \u003ctd\u003e85176200\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n    \u003ctd\u003e5A002\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energization:\u003c\/strong\u003e Ensure all power to the installation area is de-energized and locked out before commencing any work.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the SCALANCE XB213-3 switch onto a standard DIN rail. Ensure secure latching to prevent movement due to vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the power supply cables to the designated terminals. The switch supports redundant power supply; connect both primary and secondary feeds if a redundant configuration is required. Observe correct polarity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork Connections:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eConnect 10\/100 Mbps RJ45 Ethernet cables to the copper ports for local device connectivity.\u003c\/li\u003e\n      \u003cli\u003eConnect multimode fiber optic (MM FO) ST cables to the fiber ports for longer distance or noise-immune connections. Ensure proper fiber termination and cleanliness.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConsole Connection:\u003c\/strong\u003e If local configuration or diagnostics are required, connect a console cable to the dedicated console port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding of the switch and the DIN rail system to maintain signal integrity and safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Verify the operating environment is within the specified temperature range of 0 degC to +60 degC. Ensure adequate ventilation around the device.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 62443-4-2 (Industrial communication networks - Network and system security - Part 4-2: Technical security requirements for IACS components)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716763611499,"sku":"6GK5213-3BB00-2AB2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5213-3bb00-2ab2-mruvf30k3pv_2042183b-a694-460e-ad64-651eb99057e5.jpg?v=1767088932"},{"product_id":"siemens-6gk5788-2gd00-0ab0-scalance-w788-2-m12-iwlan-access-point","title":"Siemens 6GK5788-2GD00-0AB0 SCALANCE W788-2 M12 IWLAN Access Point","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5788-2GD00-0AB0 is an industrial wireless LAN (IWLAN) access point from the SCALANCE W788-2 M12 series, designed for reliable communication in demanding environments. This unit is equipped with \u003cstrong\u003etwo radios\u003c\/strong\u003e and \u003cstrong\u003esix N-CON antenna ports\u003c\/strong\u003e, supporting IEEE 802.11a\/b\/g\/h\/n standards across both \u003cstrong\u003e2.4 GHz and 5 GHz\u003c\/strong\u003e frequency bands. Each radio is capable of a gross data rate up to \u003cstrong\u003e450 Mbit\/s\u003c\/strong\u003e. Connectivity is provided through a single \u003cstrong\u003eM12 Ethernet port\u003c\/strong\u003e supporting up to 1 Gbit\/s. Power can be supplied via Power over Ethernet (PoE) or a redundant \u003cstrong\u003e24 V DC\u003c\/strong\u003e input, offering installation flexibility. The rugged, IP65-rated housing ensures protection against dust and water ingress.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px;\"\u003e\n  \u003cli\u003eDual-radio design for flexible network configuration\u003c\/li\u003e\n  \u003cli\u003eSupports IEEE 802.11a\/b\/g\/h\/n wireless standards\u003c\/li\u003e\n  \u003cli\u003eOperates on 2.4 GHz and 5 GHz frequency bands\u003c\/li\u003e\n  \u003cli\u003eGross data rate up to 450 Mbit\/s per radio\u003c\/li\u003e\n  \u003cli\u003eIP65-rated enclosure with M12 connectors for harsh environments\u003c\/li\u003e\n  \u003cli\u003eFlexible power options with PoE and redundant 24 V DC input\u003c\/li\u003e\n  \u003cli\u003eSupports advanced iFeatures via an optional KEY-PLUG\u003c\/li\u003e\n  \u003cli\u003eImplements WPA2, IEEE 802.11i, and IEEE 802.11e security and QoS protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px;\"\u003e\n  \u003cli\u003eRail and public transportation systems\u003c\/li\u003e\n  \u003cli\u003eAutomated guided vehicles (AGVs) in logistics and manufacturing\u003c\/li\u003e\n  \u003cli\u003eOutdoor wireless networks for industrial plants\u003c\/li\u003e\n  \u003cli\u003eMachine-to-machine (M2M) communication\u003c\/li\u003e\n  \u003cli\u003eMobile equipment and crane control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6GK5788-2GD00-0AB0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSCALANCE W788-2 M12\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIWLAN Access Point\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eNumber of Radios\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAntenna Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6 x N-CON\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWLAN Standards\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFrequency Bands\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2.4 GHz \/ 5 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMax. Data Rate (Gross)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e450 Mbit\/s per radio\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eEthernet Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1 x M12 (A-coded), max. 1 Gbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eRedundant 24 V DC, Power over Ethernet (PoE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIP Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSecurity Protocols\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWPA2, IEEE 802.11i, IEEE 802.11e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCertification ID\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eRAPN-W2-M12-E3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUsage Restriction\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFor operation in USA only\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.90 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.10 x 0.10 x 0.10 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. Installation, wiring, and maintenance must be performed by qualified personnel only. Failure to comply can result in severe injury or death. Always de-energize equipment and follow Lockout\/Tagout (LOTO) procedures before accessing terminals.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eEnsure all power sources to the installation area are de-energized and secured using appropriate LOTO procedures.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eMount the SCALANCE W788-2 M12 unit securely to a stable, vibration-free surface. Ensure adequate clearance for antenna installation and cable routing.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eConnect the N-CON antennas to the six designated ports. Tighten connectors to the manufacturer's specified torque to ensure the IP65 seal is maintained.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect the M12 Ethernet cable for data communication. If using PoE, ensure the cable and upstream port support the required power standard.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eIf using a local power source, connect the redundant 24 V DC supply via the M12 A-coded power connector, verifying correct polarity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eInstall the provided M12 sealing caps on all unused ports to maintain the IP65 rating.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n    \u003cspan\u003eAfter verifying all connections, remove LOTO devices and apply power to the unit for configuration and commissioning.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716764725611,"sku":"6GK5788-2GD00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5788-2gd00-0ab0-ollg0asnn2y_7fe18206-5e01-4444-b001-72f1827aadca.jpg?v=1767088974"},{"product_id":"siemens-6gk5613-0ba00-2aa3-scalance-s613-communication-module","title":"Siemens 6GK5613-0BA00-2AA3 SCALANCE S613 Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5613-0BA00-2AA3\u003c\/strong\u003e SCALANCE S613 is an industrial communication module designed for the robust protection of devices and networks within automation technology environments. This module integrates advanced firewall and VPN functionalities to secure industrial communication, supporting up to 64 devices for comprehensive network protection. The \u003cstrong\u003eSCALANCE S 613\u003c\/strong\u003e is engineered for continuous operation in demanding production settings where reliable cybersecurity is essential for operational integrity.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated firewall functionality for network protection\u003c\/li\u003e\n\u003cli\u003eVPN support for secure industrial communication\u003c\/li\u003e\n\u003cli\u003eProtects up to 64 devices via VPN\u003c\/li\u003e\n\u003cli\u003eDesigned for industrial automation environments\u003c\/li\u003e\n\u003cli\u003eRobust construction for continuous operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5613-0BA00-2AA3 SCALANCE S613 module is suitable for deployment in various industrial automation scenarios requiring enhanced network security. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSecuring control systems and PLCs from unauthorized access\u003c\/li\u003e\n\u003cli\u003eProtecting sensitive data transmission in industrial networks\u003c\/li\u003e\n\u003cli\u003eEstablishing secure remote access to automation devices via VPN\u003c\/li\u003e\n\u003cli\u003eImplementing network segmentation with firewall rules\u003c\/li\u003e\n\u003cli\u003eSafeguarding critical infrastructure in production facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15.10 x 16.90 x 12.60 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.92 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation and configuration are critical for the effective operation and security of the SCALANCE S613 module. Adhere to the following general guidelines:\u003c\/p\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before beginning any installation work, ensure that the power supply to the network components and the module's intended mounting location is completely de-energized and secured against accidental re-energization.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module securely in a suitable industrial enclosure or rack, typically on a DIN rail, ensuring adequate ventilation and clearance for cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the module to a stable and appropriate power supply according to the specified voltage range. Verify correct polarity before applying power.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNetwork Connections:\u003c\/strong\u003e Connect industrial Ethernet cables to the module's network interfaces. Ensure proper cable routing to avoid interference and physical damage. Use shielded cables where appropriate to maintain signal integrity in noisy industrial environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a reliable protective earth (PE) connection for the module and its associated equipment to minimize electromagnetic interference and ensure safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e After physical installation, configure the firewall rules and VPN settings according to the network security policy. This typically involves using Siemens engineering software.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Thoroughly test all communication paths and security functionalities (firewall, VPN) to confirm correct operation and adherence to security requirements before commissioning the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716766888299,"sku":"6GK5613-0BA00-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5613-0ba00-2aa3-scqq2ymtqe5_39c60645-dd2a-461f-973b-826b5e521415.jpg?v=1767089031"},{"product_id":"siemens-6gk5786-1fc00-0ab0-scalance-w786-1-iwlan-access-point","title":"Siemens 6GK5786-1FC00-0AB0 SCALANCE W786-1 IWLAN Access Point","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5786-1FC00-0AB0 is a SCALANCE W786-1 RJ45 Industrial Wireless LAN (IWLAN) Access Point designed for reliable data communication in demanding industrial environments. This device features a single radio module supporting IEEE 802.11a\/b\/g\/h\/n standards and operates in both \u003cstrong\u003e2.4 GHz and 5 GHz\u003c\/strong\u003e frequency bands, delivering a gross data rate of up to \u003cstrong\u003e450 Mbit\/s\u003c\/strong\u003e. Housed in a rugged \u003cstrong\u003eIP65-rated\u003c\/strong\u003e enclosure, it is suitable for operation in a wide temperature range from \u003cstrong\u003e-40 to +60 degC\u003c\/strong\u003e. Power can be supplied via Power over Ethernet (PoE) or a redundant 24 V DC input, providing flexible installation options. Advanced features, such as iFeatures, can be enabled using a KEY-PLUG (sold separately).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eSingle radio interface supporting IEEE 802.11a\/b\/g\/h\/n.\u003c\/li\u003e\n  \u003cli\u003eOperates on 2.4 GHz and 5 GHz bands.\u003c\/li\u003e\n  \u003cli\u003eGross data transmission rate up to 450 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003eThree R-SMA connectors for external antenna connection.\u003c\/li\u003e\n  \u003cli\u003eOne Gigabit Ethernet RJ45 port (up to 1 Gbit\/s).\u003c\/li\u003e\n  \u003cli\u003eSupports Power over Ethernet (PoE) for simplified cabling.\u003c\/li\u003e\n  \u003cli\u003eFlexible power input with redundant 24 V DC via terminal block.\u003c\/li\u003e\n  \u003cli\u003eRobust IP65 protection for resistance to dust and water ingress.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -40 to +60 degC.\u003c\/li\u003e\n  \u003cli\u003eSupports WPA2\/802.11i\/e for secure wireless communication.\u003c\/li\u003e\n  \u003cli\u003eiFeatures functionality enabled via optional KEY-PLUG.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eMachine-to-machine (M2M) communication in manufacturing plants.\u003c\/li\u003e\n  \u003cli\u003eConnecting mobile operator panels (HMIs) and programming devices.\u003c\/li\u003e\n  \u003cli\u003eWireless networking for automated guided vehicles (AGVs).\u003c\/li\u003e\n  \u003cli\u003eData acquisition from remote sensors and actuators.\u003c\/li\u003e\n  \u003cli\u003eOutdoor and harsh environment network installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIWLAN Access Point\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSCALANCE W786-1 RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6GK5786-1FC00-0AB0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWireless Standards\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFrequency Bands\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2.4 GHz \/ 5 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGross Data Rate\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e450 Mbit\/s per radio\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eNumber of Radios\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAntenna Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e3 x R-SMA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eEthernet Interface\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1 x RJ45, up to 1 Gbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eRedundant 24 V DC via terminal block; 110-230 V AC via optional PS791-2AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSupported\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIP Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e-40 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWireless Security\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWPA2\/802.11i\/e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCertification ID\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eEAPN-W1-RJ-E3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eScope of Delivery\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eManuals on CD-ROM (German\/English), 1x terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e30.5 x 12.7 x 33.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.90 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 15px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. Disconnect and lock out all power sources before installation or maintenance. Work must be performed by qualified personnel only. Failure to de-energize equipment can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px;\"\u003e1\u003c\/span\u003e\n    Securely mount the access point to a stable surface, such as a wall, mast, or machine frame, ensuring sufficient clearance for cable connections and heat dissipation.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px;\"\u003e2\u003c\/span\u003e\n    Connect the unit to a low-impedance functional earth (FE) ground point using the designated grounding terminal to ensure proper shielding and transient protection.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px;\"\u003e3\u003c\/span\u003e\n    Install the appropriate external antennas (not included) onto the three R-SMA connectors. Ensure connectors are tightened to the specified torque and weatherproofed if installed outdoors.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px;\"\u003e4\u003c\/span\u003e\n    Connect the network cable to the RJ45 port. If using PoE, ensure the cable is connected to a compatible PoE injector or switch.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px;\"\u003e5\u003c\/span\u003e\n    If not using PoE, connect the 24 V DC power source to the provided terminal block, observing correct polarity. For redundant power, connect a second independent 24 V DC source.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px;\"\u003e6\u003c\/span\u003e\n    After all connections are secure, re-apply power to the unit and proceed with software configuration according to the product manual.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716767281515,"sku":"6GK5786-1FC00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5786-1fc00-0ab0-otfj4zjb2vk_c1ad3156-c46c-42ba-9b9e-0beb697936e2.jpg?v=1767089046"},{"product_id":"siemens-6gk5204-0ja00-2ba6-scalance-x204irt-pro-managed-ie-irt-switch","title":"Siemens 6GK5204-0JA00-2BA6 SCALANCE X204IRT PRO Managed IE IRT Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6GK5204-0JA00-2BA6\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X204IRT PRO\u003c\/strong\u003e managed Industrial Ethernet (IE) IRT switch, designed for robust industrial networking applications. This device features a high degree of protection, \u003cstrong\u003eIP65\/67\u003c\/strong\u003e, making it suitable for deployment in harsh environments. It is equipped with four 10\/100 Mbit\/s Push-pull RJ45 ports for reliable data connections. The switch includes an error signaling contact with a set button and supports a redundant power supply for enhanced operational reliability. Functioning as a PROFINET IO device, it integrates network management capabilities and an embedded Redundancy Manager. An electronic manual on CD-ROM is included, and a C-plug is available as an optional accessory.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Industrial Ethernet (IE) IRT Switch\u003c\/li\u003e\n\u003cli\u003eIP65\/67 Degree of Protection\u003c\/li\u003e\n\u003cli\u003e4x 10\/100 Mbit\/s Push-pull RJ45 Ports\u003c\/li\u003e\n\u003cli\u003eIntegrated Error Signaling Contact with Set Button\u003c\/li\u003e\n\u003cli\u003eRedundant Power Supply Capability\u003c\/li\u003e\n\u003cli\u003ePROFINET IO Device Functionality\u003c\/li\u003e\n\u003cli\u003eNetwork Management Support\u003c\/li\u003e\n\u003cli\u003eIntegrated Redundancy Manager\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens SCALANCE X204IRT PRO switch is suitable for a range of industrial applications requiring reliable and managed network communication in challenging environments. Typical deployments include:\n\u003cul\u003e\n\u003cli\u003eDistributed PROFINET IO systems in machine building and plant engineering.\u003c\/li\u003e\n\u003cli\u003eIndustrial automation networks requiring high availability and real-time communication.\u003c\/li\u003e\n\u003cli\u003eApplications in harsh industrial environments where IP65\/67 protection is necessary.\u003c\/li\u003e\n\u003cli\u003eIntegration into network architectures requiring redundancy management for enhanced uptime.\u003c\/li\u003e\n\u003cli\u003eConnecting field devices and controllers in production lines and manufacturing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6GK5204-0JA00-2BA6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged IE IRT Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDegree of Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP65\/67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePorts\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x 10\/100 Mbit\/s Push-pull RJ45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundant\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Management\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundancy Manager\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e9.00 x 12.40 x 12.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.90 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUnknown\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The IP65\/67 rating allows for direct machine mounting in harsh environments. Secure the device firmly using appropriate fasteners to prevent vibration or accidental dislodgement.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the redundant power supply leads to the designated terminals. Observe correct polarity. Ensure the power sources are stable and within the specified voltage range for industrial equipment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Utilize industrial-grade Ethernet cables with Push-pull RJ45 connectors for the 10\/100 Mbit\/s ports. Ensure cables are securely latched and routed to avoid strain, sharp bends, or interference from power lines.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eError Signaling Contact:\u003c\/strong\u003e Connect the error signaling contact to a monitoring system or PLC input as required for system diagnostics and alerts. Test the signaling function after installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the device is properly grounded according to local electrical codes and industrial best practices to protect against electrical noise and surges.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Refer to the electronic manual on the included CD-ROM for initial setup, network configuration, and integration into the PROFINET IO system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716767773035,"sku":"6GK5204-0JA00-2BA6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5204-0ja00-2ba6-qm2utikm2zq_c4783804-c957-44b0-a00e-05921ceef89f.jpg?v=1767089065"},{"product_id":"siemens-6gk5328-4fs00-2rr3-scalance-xr328-4c-wg-managed-ie-switch","title":"Siemens 6GK5328-4FS00-2RR3 SCALANCE XR328-4C WG Managed IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6GK5328-4FS00-2RR3\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE XR328-4C WG\u003c\/strong\u003e managed Industrial Ethernet switch designed for 19-inch rack mounting. It provides extensive connectivity with 24 electrical 10\/100 Mbit\/s ports and 4 combo 1000 Mbit\/s ports, which can be configured for either electrical or optical connections. This device functions as a \u003cstrong\u003ePROFINET Device\u003c\/strong\u003e, supporting network management and redundancy features for robust industrial communication networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManaged Industrial Ethernet switch\u003c\/li\u003e\n\u003cli\u003e19-inch rack mountable design\u003c\/li\u003e\n\u003cli\u003e24 x 10\/100 Mbit\/s electrical ports\u003c\/li\u003e\n\u003cli\u003e4 x 1000 Mbit\/s combo ports (electrical or optical)\u003c\/li\u003e\n\u003cli\u003eLED diagnostics for operational status\u003c\/li\u003e\n\u003cli\u003eIntegrated Reset button\u003c\/li\u003e\n\u003cli\u003eConsole port for local configuration\u003c\/li\u003e\n\u003cli\u003ePROFINET Device functionality\u003c\/li\u003e\n\u003cli\u003eComprehensive network management capabilities\u003c\/li\u003e\n\u003cli\u003eRedundancy manager for high availability\u003c\/li\u003e\n\u003cli\u003ePower supply requirement: 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5328-4FS00-2RR3 SCALANCE XR328-4C WG is suitable for deployment in various industrial environments, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEstablishing robust Industrial Ethernet networks within control cabinets and plant floors.\u003c\/li\u003e\n\u003cli\u003eIntegrating into PROFINET-based automation systems as a network device.\u003c\/li\u003e\n\u003cli\u003eCreating data backbones for plant-wide communication infrastructure.\u003c\/li\u003e\n\u003cli\u003eApplications requiring managed network functionality and redundancy for high availability.\u003c\/li\u003e\n\u003cli\u003eConnecting a mix of Fast Ethernet and Gigabit Ethernet devices in a single network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e19-inch rack\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eElectrical Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 x 10\/100 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCombo Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 x 1000 Mbit\/s (electrical or optical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e48.30 x 12.70 x 4.40 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.70 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized before beginning any work. Verify with appropriate lockout\/tagout procedures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Install the SCALANCE XR328-4C WG into a standard 19-inch equipment rack using appropriate mounting hardware. Ensure adequate ventilation space around the unit.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 24 V DC power supply to the designated power input terminals. Observe correct polarity to prevent damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Connect Ethernet cables to the 10\/100 Mbit\/s electrical ports and\/or 1000 Mbit\/s combo ports as required by the network design. For optical connections, use appropriate fiber optic transceivers and cables.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConsole Connection:\u003c\/strong\u003e For initial configuration or diagnostics, connect a terminal device to the console port using a suitable cable.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the switch chassis is properly grounded to the rack and facility ground to protect against electrical interference and surges.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Up:\u003c\/strong\u003e Once all connections are secure and verified, re-energize the power supply. Observe the LED diagnostics for proper boot-up and operational status.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5328-4FS00-2RR3 SCALANCE XR328-4C WG does not have UL\/FM approval.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716768133483,"sku":"6GK5328-4FS00-2RR3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5328-4fs00-2rr3-ejqpmidlr0d_98373a6b-13fb-4247-b052-64ab119a370c.jpg?v=1767089081"},{"product_id":"siemens-6gk5216-0ha00-2as6-scalance-xp216-managed-industrial-ethernet-switch","title":"Siemens 6GK5216-0HA00-2AS6 SCALANCE XP216 Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5216-0HA00-2AS6 is a managed Industrial Ethernet switch from the SCALANCE XP216 series, designed for reliable network management in demanding industrial environments. This device provides a total of 16 ports, including \u003cstrong\u003e12 x 10\/100 Mbps M12 ports\u003c\/strong\u003e and \u003cstrong\u003e4 x 10\/100\/1000 Mbps M12 ports\u003c\/strong\u003e for versatile connectivity. Engineered for harsh conditions, the switch features a rugged enclosure with an \u003cstrong\u003eIP65 protection rating\u003c\/strong\u003e and supports redundant power supplies for high operational availability. It functions as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e and is certified to \u003cstrong\u003eIEC 62443-4-2\u003c\/strong\u003e, ensuring compliance with modern industrial cybersecurity standards.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManaged Layer 2 Industrial Ethernet switch\u003c\/li\u003e\n  \u003cli\u003e12 x 10\/100 Mbps ports with M12 connectors\u003c\/li\u003e\n  \u003cli\u003e4 x 10\/100\/1000 Mbps ports with M12 connectors\u003c\/li\u003e\n  \u003cli\u003eIP65-rated enclosure for protection against dust and water ingress\u003c\/li\u003e\n  \u003cli\u003eFunctions as a PROFINET IO device for seamless automation integration\u003c\/li\u003e\n  \u003cli\u003eSupports redundant ring operation for network fault tolerance\u003c\/li\u003e\n  \u003cli\u003eRedundant power supply input for increased system uptime\u003c\/li\u003e\n  \u003cli\u003eIntegrated LED diagnostics for at-a-glance status monitoring\u003c\/li\u003e\n  \u003cli\u003eIncludes an error signaling contact for external fault indication\u003c\/li\u003e\n  \u003cli\u003eCertified according to IEC 62443-4-2 for industrial security\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine building and factory automation\u003c\/li\u003e\n  \u003cli\u003eAutomotive manufacturing and assembly lines\u003c\/li\u003e\n  \u003cli\u003eTransportation systems (rail, traffic control)\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing plants\u003c\/li\u003e\n  \u003cli\u003eApplications requiring cabinet-free, decentralized networking\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; background-color: #f7fafc;\"\u003eCategory\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; background-color: #f7fafc;\"\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eSCALANCE XP216\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e6GK5216-0HA00-2AS6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eTotal Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eFast Ethernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e12 x 10\/100 Mbps, M12 D-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eGigabit Ethernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e4 x 10\/100\/1000 Mbps, M12 X-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eIndustrial Protocol Support\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003ePROFINET IO Device\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eSecurity Certification\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eIEC 62443-4-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e0.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e28.0 x 20.0 x 4.9 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages can cause electric shock and burns. Disconnect, lock out, and tag out all power sources before installing or servicing this equipment. Installation must be performed by qualified personnel only.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, ensure all related power sources to the control panel or mounting location are completely de-energized, locked out, and tagged out according to site safety procedures.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount the Switch:\u003c\/strong\u003e Securely mount the SCALANCE XP216 switch to a stable, flat surface or DIN rail (if an adapter is used) in its intended operational environment. Ensure adequate clearance for cable routing and heat dissipation.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect a low-impedance protective earthing conductor to the designated grounding terminal on the switch chassis. A proper ground connection is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eTerminate Power Supplies:\u003c\/strong\u003e Connect the primary and, if used, redundant power supply cables to the M12 power connector. Verify the voltage and polarity match the device's specifications before connection.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Network Cables:\u003c\/strong\u003e Connect the Ethernet cables to the appropriate M12 ports. Ensure connectors are fully seated and tightened to the manufacturer's recommended torque to maintain the IP65 rating. Use the included dust caps for any unused ports.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Signaling Contact:\u003c\/strong\u003e If required, connect the wiring for the error signaling contact to the designated terminals. This allows for remote monitoring of the switch's health status.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower On and Verify:\u003c\/strong\u003e After removing all locks and tags, re-energize the system. Observe the device's LEDs to confirm correct power-up, network link status, and activity.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716769575275,"sku":"6GK5216-0HA00-2AS6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5216-0ha00-2as6-yetjjxaiwpz_de27f7f4-df83-4157-95e9-f2f3c02c2e36.jpg?v=1767089132"},{"product_id":"siemens-6gk1161-6aa02-simatic-communications-processor-cp-1616-pci-card","title":"Siemens 6GK1161-6AA02 SIMATIC Communications Processor CP 1616 PCI Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6GK1161-6AA02\u003c\/strong\u003e is a \u003cstrong\u003eCommunications Processor CP 1616 PCI card\u003c\/strong\u003e designed for industrial PC-based PROFINET IO communication. This module operates as a 32-bit PCI card with support for 33\/66 MHz bus speeds and 3.3\/5 V signaling. It integrates an \u003cstrong\u003eASIC ERTEC 400\u003c\/strong\u003e for efficient real-time processing and features a 4-port real-time switch with RJ45 connectors for direct connection to PROFINET IO networks. The \u003cstrong\u003e6GK1161-6AA02\u003c\/strong\u003e is compatible with the DK-16XX PN IO development kit and NCM PC for configuration and management within SIMATIC automation environments.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePCI card interface (32-bit, 33\/66 MHz, 3.3\/5 V)\u003c\/li\u003e\n  \u003cli\u003eIntegrated ASIC ERTEC 400\u003c\/li\u003e\n  \u003cli\u003ePROFINET IO connectivity\u003c\/li\u003e\n  \u003cli\u003e4-port real-time switch with RJ45 connectors\u003c\/li\u003e\n  \u003cli\u003eCompatibility with DK-16XX PN IO development kit\u003c\/li\u003e\n  \u003cli\u003eSupports NCM PC for configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial PC-based PROFINET IO communication\u003c\/li\u003e\n  \u003cli\u003eReal-time Ethernet applications in automation systems\u003c\/li\u003e\n  \u003cli\u003eIntegration of industrial PCs into PROFINET networks\u003c\/li\u003e\n  \u003cli\u003eData exchange between PC applications and PROFINET devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInterface Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePCI card (32 bit; 33\/66M Hz; 3.3\/5 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eASIC\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eERTEC 400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET IO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4-port real-time switch (RJ45)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.80 x 16.70 x 10.70 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.31 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePCI Interface:\u003c\/strong\u003e For connection to the industrial PC's PCI slot.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRJ45 Ports (x4):\u003c\/strong\u003e For connection to the PROFINET IO network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Off:\u003c\/strong\u003e Ensure the industrial PC is completely powered down and disconnected from the main power supply before opening the chassis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen PC Chassis:\u003c\/strong\u003e Carefully open the PC chassis to access the internal components and expansion slots.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocate PCI Slot:\u003c\/strong\u003e Identify an available 32-bit PCI slot compatible with the card's voltage requirements (3.3V or 5V).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsert Card:\u003c\/strong\u003e Align the \u003cstrong\u003e6GK1161-6AA02\u003c\/strong\u003e card with the chosen PCI slot and firmly press it down until it is fully seated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Card:\u003c\/strong\u003e Use the retaining bracket or screw to secure the card in place within the PC chassis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClose PC Chassis:\u003c\/strong\u003e Reassemble and close the PC chassis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnect PROFINET Cables:\u003c\/strong\u003e Connect standard Ethernet cables with RJ45 connectors from your PROFINET IO network to the available RJ45 ports on the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower On:\u003c\/strong\u003e Reconnect the PC to the power supply and power it on.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDriver Installation:\u003c\/strong\u003e Install the necessary drivers and NCM PC software as required for the operating system to recognize and configure the CP 1616 card for PROFINET IO communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716770754923,"sku":"6GK1161-6AA02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1161-6aa02-1p5atsshcgo_0b2f7468-c29f-4b2b-bd12-ce03e90bf2e5.jpg?v=1767089183"},{"product_id":"siemens-6gk7343-2ah01-0xa0-simatic-net-cp-343-2-as-interface-communications-processor","title":"Siemens 6GK7343-2AH01-0XA0 SIMATIC NET CP 343-2 AS-Interface Communications Processor","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThis module is the Siemens 6GK7343-2AH01-0XA0, a CP 343-2 communications processor from the SIMATIC NET family. It is engineered to connect \u003cstrong\u003eSIMATIC S7-300\u003c\/strong\u003e programmable controllers and \u003cstrong\u003eET 200M\u003c\/strong\u003e distributed I\/O systems to an AS-Interface network. The processor ensures reliable data exchange and system integration by adhering to the \u003cstrong\u003eAS-Interface Specification V3.0\u003c\/strong\u003e. Its compact design is suitable for straightforward installation within standard control cabinets, providing a robust link between control systems and field-level devices in demanding industrial automation environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"color: #2d3748; list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Provides AS-Interface connectivity for SIMATIC S7-300 and ET 200M systems.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Fully compliant with AS-Interface Specification V3.0.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Designed for seamless integration into the SIMATIC S7-300 rack.\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Compact form factor for efficient use of cabinet space.\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"color: #2d3748; list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Automated production lines\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Material handling and conveyor systems\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Process control and monitoring\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e\n        Building automation systems\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Family\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC NET\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCP 343-2\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommunications Processor\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCompatible Systems\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC S7-300, ET 200M\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePrimary Protocol\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eAS-Interface\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProtocol Specification\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eAS-Interface Specification V3.0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePhase-Out\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePredecessor Model\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6GK7343-2AH00-0XA0\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e0.30 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e4.0 cm x 12.0 cm x 12.5 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85176200\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEAR99\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 16px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. Installation, modification, or removal of this module must be performed only by qualified electrical personnel. Failure to de-energize the system and follow Lockout\/Tagout (LOTO) procedures before servicing can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold;\"\u003e1\u003c\/span\u003e\n        Ensure all power to the SIMATIC S7-300 rack and associated equipment is disconnected at the source. Apply appropriate LOTO devices as per site safety policy.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold;\"\u003e2\u003c\/span\u003e\n        Verify the absence of voltage using a properly rated test instrument before proceeding.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold;\"\u003e3\u003c\/span\u003e\n        Identify an available slot on the S7-300 mounting rail. Align the module with the rail and hook its top edge before pivoting it downward to snap securely into place.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold;\"\u003e4\u003c\/span\u003e\n        Slide the module horizontally to engage with the adjacent module's bus connector. Ensure the bus connector is fully seated to establish a reliable backplane connection.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold;\"\u003e5\u003c\/span\u003e\n        Connect the AS-Interface network cable to the designated port on the front of the module. Ensure the connection is secure.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px;\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; position: absolute; left: 0; top: 0; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold;\"\u003e6\u003c\/span\u003e\n        After all connections are made and verified, remove LOTO devices and restore power to the system for commissioning.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716772196715,"sku":"6GK7343-2AH01-0XA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk7343-2ah01-0xa0-m0yvfjycqp3_1804ccb2-caa8-4985-9b54-65f25a69cbbf.jpg?v=1767089234"},{"product_id":"siemens-6gk7443-1gx10-0xe0-simatic-s7-400-cp-443-1-it-communication-processor","title":"Siemens 6GK7443-1GX10-0XE0 SIMATIC S7-400 CP 443-1 IT Communication Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSiemens 6GK7443-1GX10-0XE0\u003c\/strong\u003e is a SIMATIC NET, \u003cstrong\u003eCP 443-1 IT Communications Processor\u003c\/strong\u003e designed for connecting SIMATIC S7-400 PLCs to Industrial Ethernet networks. This module facilitates communication via ISO and TCP\/IP protocols, supporting essential functions such as S7 Communication, Fetch\/Write, Send\/Receive, E-mail, and WWW services. It operates at a data transfer rate of 10\/100 Mbit, enabling robust data exchange and remote capabilities for industrial automation applications. The 6GK7443-1GX10-0XE0 is categorized as an obsolete product phase.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for SIMATIC S7-400 PLC integration.\u003c\/li\u003e\n  \u003cli\u003eSupports Industrial Ethernet connectivity.\u003c\/li\u003e\n  \u003cli\u003eCompatible with ISO and TCP\/IP communication protocols.\u003c\/li\u003e\n  \u003cli\u003eEnables S7 Communication, Fetch\/Write, and Send\/Receive functions.\u003c\/li\u003e\n  \u003cli\u003eProvides E-mail and WWW capabilities.\u003c\/li\u003e\n  \u003cli\u003eOperates at 10\/100 Mbit data transfer rates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnecting SIMATIC S7-400 controllers to plant-wide Industrial Ethernet networks.\u003c\/li\u003e\n  \u003cli\u003eFacilitating data exchange and process control between S7-400 PLCs and other Ethernet-enabled devices.\u003c\/li\u003e\n  \u003cli\u003eImplementing remote monitoring and control solutions via web interfaces.\u003c\/li\u003e\n  \u003cli\u003eEnabling automated E-mail notifications for system events or alarms.\u003c\/li\u003e\n  \u003cli\u003eIntegration into distributed control systems requiring robust S7-400 communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic S7\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNET\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType of Product\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eData Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e10\/100 Mbit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProtocols Supported\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eISO, TCP\/IP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCompatibility\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC S7-400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2.50 x 29.20 x 21.60 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.70 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85389091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the SIMATIC S7-400 system is de-energized before installing or removing the module.\u003c\/li\u003e\n  \u003cli\u003eInsert the 6GK7443-1GX10-0XE0 module into an available slot on the S7-400 rack, ensuring it is correctly seated and secured.\u003c\/li\u003e\n  \u003cli\u003eConnect the Industrial Ethernet cables to the module's ports. Use appropriate shielded cables for industrial environments to minimize interference.\u003c\/li\u003e\n  \u003cli\u003eVerify proper grounding of the S7-400 rack and associated components to ensure system stability and safety.\u003c\/li\u003e\n  \u003cli\u003eAfter installation, re-energize the system and observe the module's status indicators to confirm correct operation and network connectivity.\u003c\/li\u003e\n  \u003cli\u003eConfigure the communication parameters within the SIMATIC programming software to establish network connections and define communication services (e.g., S7 Communication, Fetch\/Write).\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716775014763,"sku":"6GK7443-1GX10-0XE0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk7443-1gx10-0xe0-sfbaec5sxqr_180da340-afed-4c3d-a4e9-3be61d8fa457.jpg?v=1767089336"},{"product_id":"siemens-6gk5778-1gy00-0ta0-scalance-w778-1-m12-eec-iwlan-access-point","title":"Siemens 6GK5778-1GY00-0TA0 SCALANCE W778-1 M12 EEC IWLAN Access Point","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens 6GK5778-1GY00-0TA0 SCALANCE W778-1 M12 EEC, an industrial wireless LAN (IWLAN) access point designed for reliable communication in demanding environments. The device features a single radio interface supporting \u003cstrong\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/strong\u003e standards for operation in both \u003cstrong\u003e2.4 GHz and 5 GHz\u003c\/strong\u003e frequency bands, achieving a gross data rate of up to \u003cstrong\u003e300 Mbit\/s\u003c\/strong\u003e. It is equipped with an integrated 2-port switch with Power over Ethernet (PoE) capability, utilizing rugged M12 connectors for both network and power connections. The unit's robust \u003cstrong\u003eIP65-rated\u003c\/strong\u003e enclosure, conformal coating, and wide operating temperature range from \u003cstrong\u003e-30 to 70 degC\u003c\/strong\u003e ensure dependable performance in transportation, manufacturing, and process control applications. Advanced iFeatures can be enabled via an optional KEY-PLUG.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eSingle radio interface for flexible network deployment.\u003c\/li\u003e\n  \u003cli\u003eSupports IEEE 802.11a\/b\/g\/h\/n wireless standards.\u003c\/li\u003e\n  \u003cli\u003eDual-band operation at 2.4 GHz and 5 GHz.\u003c\/li\u003e\n  \u003cli\u003eMaximum gross data rate of 300 Mbit\/s.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 2-port switch with PoE functionality.\u003c\/li\u003e\n  \u003cli\u003eRedundant 24 V DC power supply input.\u003c\/li\u003e\n  \u003cli\u003eRugged M12 A-coded connectors for network and power.\u003c\/li\u003e\n  \u003cli\u003eIP65-rated enclosure for protection against dust and water ingress.\u003c\/li\u003e\n  \u003cli\u003eConformal coating for enhanced durability in harsh chemical or humid environments.\u003c\/li\u003e\n  \u003cli\u003eExtended operating temperature range (-30 to 70 degC).\u003c\/li\u003e\n  \u003cli\u003eiFeatures support enabled via an optional KEY-PLUG.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eRailway and transportation systems (EN 50155 compliant).\u003c\/li\u003e\n  \u003cli\u003eAutomated Guided Vehicles (AGVs) and mobile equipment.\u003c\/li\u003e\n  \u003cli\u003eMachine-to-machine (M2M) communication networks.\u003c\/li\u003e\n  \u003cli\u003eProcess automation and control systems.\u003c\/li\u003e\n  \u003cli\u003eOutdoor and washdown industrial environments.\u003c\/li\u003e\n  \u003cli\u003eAutomotive manufacturing and logistics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eCategory\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: 600; color: #1a365d;\"\u003eGeneral\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5778-1GY00-0TA0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIWLAN Access Point\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: 600; color: #1a365d;\"\u003eWireless Communication\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eSupported Standards\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eFrequency Bands\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2.4 GHz \/ 5 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eNumber of Radios\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eGross Data Rate\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e300 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eSecurity Protocols\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eWPA2\/802.11i\/e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eAntenna Connection\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2 x N-CON port\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: 600; color: #1a365d;\"\u003eWired Interfaces\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2 x M12, A-coded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eEthernet Speed\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMax. 100 Mbit\/s\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eSwitch Functionality\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntegrated 2-port switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSupported\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: 600; color: #1a365d;\"\u003eElectrical\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eRedundant 24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: 600; color: #1a365d;\"\u003eMechanical \u0026amp; Environmental\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eIngress Protection\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e-30 to 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eSpecial Features\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eConformal coating, KEY-PLUG slot for iFeatures\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: 600; color: #1a365d;\"\u003eCompliance \u0026amp; Certifications\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eRailway Standard\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEN 50155\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eFire Protection Standard\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEN 45545\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eCERT ID\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMSN65-W1-M12-E2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: 600; color: #1a365d;\"\u003eLogistics \u0026amp; Trade\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24.0 x 18.5 x 10.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.60 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; padding-left: 25px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cp style=\"color: #c53030; font-weight: bold; margin-top: 0;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/p\u003e\n  \u003cp style=\"color: #2d3748; margin-bottom: 0;\"\u003eDisconnect all power sources and follow Lockout\/Tagout (LOTO) procedures before installation or maintenance. Work must be performed by qualified personnel only. Failure to de-energize equipment can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eMount the device securely to a stable surface or panel, ensuring adequate clearance for M12 and N-CON connectors and allowing for proper heat dissipation.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eConnect the appropriate antennas to the two N-CON ports. Ensure connections are tightened to the specified torque to maintain the IP65 rating. Use the included M12 sealing caps on any unused ports.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eTerminate the M12 Ethernet cables for network connectivity. The device can be powered via PoE through these ports or by a separate DC power source.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eIf not using PoE, connect the redundant 24 V DC power supply using the appropriate M12 power connector. Verify correct polarity before energizing.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eIf using iFeatures, insert the correct Siemens KEY-PLUG into the designated slot before powering on the device.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003eAfter all connections are secure and verified, re-energize the system and proceed with software configuration according to the product manual.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716775047531,"sku":"6GK5778-1GY00-0TA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5778-1gy00-0ta0-3rvpj4bs24d_db137f19-3601-4249-a9ba-a77616052814.jpg?v=1767089337"},{"product_id":"siemens-6gk5992-4am00-8aa0-scalance-x-media-module-mm992-4ld","title":"Siemens 6GK5992-4AM00-8AA0 SCALANCE X Media Module MM992-4LD","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6GK5992-4AM00-8AA0\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X\u003c\/strong\u003e accessory, specifically the \u003cstrong\u003eMedia Module MM992-4LD\u003c\/strong\u003e. This module is designed to expand the connectivity options of compatible SCALANCE X devices within industrial network environments. It features \u003cstrong\u003e4x 1000 Mbit\/s SC-ports\u003c\/strong\u003e for optical communication, supporting \u003cstrong\u003esingle-mode optical fiber\u003c\/strong\u003e with a maximum transmission range of \u003cstrong\u003e10 km\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e4x 1000 Mbit\/s SC-ports for optical communication\u003c\/li\u003e\n  \u003cli\u003eSupports single-mode optical fiber\u003c\/li\u003e\n  \u003cli\u003eMaximum optical transmission distance of 10 km\u003c\/li\u003e\n  \u003cli\u003eDesigned as an accessory for Siemens SCALANCE X series\u003c\/li\u003e\n  \u003cli\u003eActive product phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eExtending industrial Ethernet networks over long distances using optical fiber.\u003c\/li\u003e\n  \u003cli\u003eIntegrating high-speed optical data transmission into SCALANCE X infrastructures.\u003c\/li\u003e\n  \u003cli\u003eDeployment in environments requiring robust and interference-resistant communication.\u003c\/li\u003e\n  \u003cli\u003eUpgrading existing SCALANCE X switches with additional optical connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMedia Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePorts\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x 1000 Mbit\/s SC-ports\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Fiber Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSingle-mode optical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax. Optical Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e10 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12.03 x 27.55 x 2.23 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the host SCALANCE X device is de-energized and isolated from power sources before installation.\u003c\/li\u003e\n  \u003cli\u003eCarefully insert the \u003cstrong\u003eMM992-4LD Media Module\u003c\/strong\u003e into the designated slot on the compatible SCALANCE X device, ensuring proper alignment.\u003c\/li\u003e\n  \u003cli\u003eSecure the module in place according to the host device's mechanical fastening mechanism.\u003c\/li\u003e\n  \u003cli\u003eConnect single-mode SC fiber optic cables to the module's \u003cstrong\u003eSC-ports\u003c\/strong\u003e. Ensure proper fiber polarity for transmit and receive paths.\u003c\/li\u003e\n  \u003cli\u003eRoute fiber optic cables to prevent sharp bends, excessive tension, or crushing, which can degrade optical performance.\u003c\/li\u003e\n  \u003cli\u003eVerify all connections are secure and clean.\u003c\/li\u003e\n  \u003cli\u003eRe-energize the SCALANCE X device and verify module operation and network communication through diagnostic indicators.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716775571819,"sku":"6GK5992-4AM00-8AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5992-4am00-8aa0-kqi3f1c2kyb_dba3f56b-83e4-459d-afaf-b175728bde90.jpg?v=1767089354"},{"product_id":"siemens-6gk5204-0ba00-2ba3-scalance-x204irt-managed-ie-irt-switch","title":"Siemens 6GK5204-0BA00-2BA3 SCALANCE X204IRT Managed IE IRT Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5204-0BA00-2BA3 is a managed Industrial Ethernet switch from the SCALANCE X204IRT series, designed for isochronous real-time (IRT) motion control applications. This device provides reliable network management and high availability for demanding industrial automation systems. It features \u003cstrong\u003e4x 10\/100 Mbit\/s RJ45 ports\u003c\/strong\u003e for connecting automation components and serves as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e with an integrated Redundancy Manager. The switch is equipped with an error signaling contact and supports a redundant power supply to ensure continuous operation and rapid fault diagnosis in critical production environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eFour 10\/100 Mbit\/s RJ45 ports for network connectivity.\u003c\/li\u003e\n  \u003cli\u003eManaged switch with integrated network management functions.\u003c\/li\u003e\n  \u003cli\u003eFunctions as a PROFINET IO device for seamless automation integration.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Redundancy Manager enhances network availability.\u003c\/li\u003e\n  \u003cli\u003eFeatures an error signaling contact with a set pushbutton for diagnostics.\u003c\/li\u003e\n  \u003cli\u003eSupports redundant power supply inputs for increased operational reliability.\u003c\/li\u003e\n  \u003cli\u003eCompatible with optional C-PLUG for configuration backup and rapid device replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eHigh-performance machine networks requiring isochronous real-time (IRT) communication.\u003c\/li\u003e\n  \u003cli\u003ePROFINET-based automation and motion control systems.\u003c\/li\u003e\n  \u003cli\u003eProduction lines with high demands on network availability and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eNetwork infrastructure in manufacturing cells and process control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSCALANCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6GK5204-0BA00-2BA3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManaged Industrial Ethernet IRT Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNumber of Ports\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePort Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e10\/100 Mbit\/s RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSupported Protocol\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFINET IO\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.92 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Provided)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6.0 cm x 12.4 cm x 12.5 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect and lock out all power sources to the control panel before installation or maintenance. Failure to de-energize equipment can result in severe electrical shock, injury, or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    Securely mount the switch onto a standard 35mm DIN rail inside a suitable enclosure, ensuring adequate clearance for ventilation and cable access.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    Connect the primary and, if used, redundant DC power supplies to the designated terminals. Verify correct polarity before energizing the unit.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    Establish a low-impedance connection from the switch's functional earth terminal to the enclosure's main ground point using a short, appropriately sized conductor.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    Connect shielded RJ45 Ethernet cables to the ports. Ensure connectors are fully seated and that cable shields are properly terminated at one end to prevent ground loops.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: white; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    Wire the error signaling contact to the appropriate monitoring system or PLC input as required for system diagnostics and fault alarming.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716776817003,"sku":"6GK5204-0BA00-2BA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5204-0ba00-2ba3-0perw1dfdkj_cc6bf609-313e-4ba4-81fe-9fbbf3c59ceb.jpg?v=1767089393"},{"product_id":"siemens-6gk1102-0ab00-sinec-h1-ssv-102-b-fan-out-unit","title":"Siemens 6GK1102-0AB00 SINEC H1 SSV 102 B Fan-Out Unit","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK1102-0AB00\u003c\/strong\u003e is a \u003cstrong\u003eSINEC H1 SSV 102 B fan-out unit\u003c\/strong\u003e designed to facilitate network expansion within industrial communication architectures. This unit features 5 interfaces and is specifically designed for 19-inch mounting rack installation, providing a centralized point for connecting multiple H1 network nodes. As a key component of the legacy \u003cstrong\u003eSINEC H1\u003c\/strong\u003e communication system, it supports reliable data distribution in industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e SINEC H1 SSV 102 B Fan-Out Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e 5 integrated interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 19-inch rack-mount design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Industrial network expansion and signal distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLegacy industrial network infrastructure\u003c\/li\u003e\n\u003cli\u003eSINEC H1 network node distribution\u003c\/li\u003e\n\u003cli\u003eCentralized industrial communication rack systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSinec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e26.00 cm x 25.50 cm x 12.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for secure installation in a standard 19-inch industrial communication rack. Ensure proper mechanical fastening to support the weight of the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the H1 network cables to the 5 available interfaces. Ensure proper shielding and connector seating to maintain signal integrity across the H1 bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the unit chassis to the rack ground to minimize electromagnetic interference and ensure safe operation within the electrical cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e While compact, ensure adequate airflow within the rack to prevent internal component degradation over extended operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Verify system-wide compatibility with existing SINEC H1 network infrastructure prior to integration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716777832811,"sku":"6GK1102-0AB00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1102-0ab00-m4iomad55ef_1f7c0131-f0a3-49f1-b0c7-d97fdcabecb1.jpg?v=1767089433"},{"product_id":"siemens-6gk5788-2fc00-0ab0-scalance-w788-2-iwlan-access-point","title":"Siemens 6GK5788-2FC00-0AB0 SCALANCE W788-2 IWLAN Access Point","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6GK5788-2FC00-0AB0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCALANCE W788-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindustrial IWLAN access point engineered for high-performance wireless communication in automation environments. This unit features 2 integrated radios supporting IEEE 802.11a\/b\/g\/h\/n standards across both 2.4 GHz and 5 GHz frequency bands, providing a gross data rate of 450 Mbit\/s per radio. Designed for rugged use, the device includes 6 R-SMA antenna ports, a single 1 Gbit\/s RJ45 interface, and supports Power-over-Ethernet (PoE) as well as redundant 24V DC input via terminal block.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWireless Standard:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEEE 802.11a\/b\/g\/h\/n (2.4\/5 GHz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGross 450 Mbit\/s per radio\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1x RJ45 (max. 1 Gbit\/s), 6x R-SMA antenna ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePoE support and redundant 24V DC input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWPA2\/802.11i\/e support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP30 rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20 degC to +60 degC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eiFeatures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupported via KEY-PLUG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCERT ID: RAPN-W2-RJ-E3 (Only for operation in USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWireless factory automation networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated Guided Vehicle (AGV) systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMobile industrial terminal communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed data exchange in manufacturing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIMATIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCALANCE W788-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRadios\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 Mbit\/s per radio\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 degC to +60 degC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant 24V DC \/ PoE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.40 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85176200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eECCN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5A002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAntenna Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure antennas are securely attached to the 6 R-SMA ports. Avoid blocking antenna signals with metal objects to maintain wireless coverage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe device supports redundant 24V DC supply via terminal blocks or Power-over-Ethernet. Use shielded cables to ensure electrical stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProperly ground the housing to prevent electrostatic discharge, especially in sensitive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis device is strictly designated for operation within the USA. Verify national approvals before deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the provided plug slot for standard installation in industrial control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716778979691,"sku":"6GK5788-2FC00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5788-2fc00-0ab0-k0o5kij4wz1_c2b7fe8a-6f05-4f95-b0fb-5e00c80b0923.jpg?v=1767089461"},{"product_id":"siemens-6gk5788-1gd00-0ab0-scalance-w788-1-iwlan-access-point","title":"Siemens 6GK5788-1GD00-0AB0 SCALANCE W788-1 IWLAN Access Point","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK5788-1GD00-0AB0\u003c\/strong\u003e is a high-performance \u003cstrong\u003eSCALANCE W788-1 M12\u003c\/strong\u003e industrial wireless LAN (IWLAN) access point, engineered for reliable data communication in demanding industrial environments. Featuring one radio module and three N-Connect antenna ports, it supports the IEEE 802.11a\/b\/g\/h\/n standards across both 2.4 GHz and 5 GHz frequency bands, delivering a gross data rate of up to 450 Mbit\/s per radio. The unit is designed for durability with an \u003cstrong\u003eIP65\u003c\/strong\u003e degree of protection and operates within an ambient temperature range of -20 degC to +60 degC. Connectivity is managed via a high-speed 1 Gbit\/s M12 port and redundant 24 V DC power supply inputs. Advanced security is handled via WPA2\/802.11i\/e protocols, and it features a plug slot for additional \"iFeatures\" via a Key Plug.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadio Standard:\u003c\/strong\u003e IEEE 802.11a\/b\/g\/h\/n (2.4\/5 GHz dual-band support).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThroughput:\u003c\/strong\u003e Gross 450 Mbit\/s per radio.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e 1x M12 port (max. 1 Gbit\/s) and 3x N-Connect antenna ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Redundant 24 V DC input and Power-over-Ethernet (PoE) support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e IP65-rated housing suitable for harsh industrial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e WPA2\/802.11i\/e support for secure wireless transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeature Expansion:\u003c\/strong\u003e Support for iFeatures via optional Key Plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial automation and mobile robotic systems (AGVs).\u003c\/li\u003e\n\u003cli\u003eReal-time machine-to-machine (M2M) communication.\u003c\/li\u003e\n\u003cli\u003eWireless infrastructure for manufacturing logistics and tracking.\u003c\/li\u003e\n\u003cli\u003eHigh-availability industrial control networks.\u003c\/li\u003e\n\u003cli\u003eData acquisition in areas difficult to cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5788-1GD00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN Access Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Bands\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 GHz \/ 5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 Mbit\/s (gross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x M12 (1 Gbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the device is mounted securely in a location that minimizes obstructions to maintain the wireless signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAntenna Placement:\u003c\/strong\u003e Connect antennas to the three N-Connect ports; ensure correct orientation for the required radio coverage pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowering:\u003c\/strong\u003e Utilize redundant 24 V DC power feeds or PoE as required by the installation design; ensure M12 A-coded connectors are properly seated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegional Compliance:\u003c\/strong\u003e Note that this specific model is restricted to operation in the USA; always verify national radio approvals before deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Use the provided software tools via the Ethernet interface to configure security (WPA2) and network parameters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779110763,"sku":"6GK5788-1GD00-0AB0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5788-1gd00-0ab0-jdjh0l1bi4l_490fd6d3-2143-44d3-8ae2-8ba649275439.jpg?v=1767089466"},{"product_id":"siemens-6gk5213-3bd00-2tb2-scalance-xb213-3-managed-industrial-switch","title":"Siemens 6GK5213-3BD00-2TB2 SCALANCE XB213-3 Managed Industrial Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK5213-3BD00-2TB2\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE XB213-3\u003c\/strong\u003e managed Layer 2 industrial Ethernet (IE) switch, designed to provide high-performance connectivity in automated environments. This unit features 13 RJ45 ports (10\/100 Mbps) and 3 multi-mode (MM) fiber-optic (FO) SC ports, facilitating both standard copper and long-distance fiber transmission. Engineered for critical infrastructure, it is \u003cstrong\u003eIEC 62443-4-2 certified\u003c\/strong\u003e, ensuring robust cybersecurity compliance. The switch includes a console port for configuration, diagnostic LEDs for real-time status monitoring, and supports redundant power supplies to maintain network uptime in the event of a power failure. It is designed for standard rail mounting and operates within a temperature range of 0 Celsius to +60 Celsius, with a default configuration optimized for EtherNet\/IP protocols.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Configuration:\u003c\/strong\u003e 13x 10\/100 Mbps RJ45 ports and 3x MM FO SC ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManagement:\u003c\/strong\u003e Layer 2 managed switch with console port support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Supports redundant power supply input for increased reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e IEC 62443-4-2 certified for industrial network security.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Integrated status LEDs for rapid troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Pre-configured for EtherNet\/IP environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial automation and control networks (PROFINET\/EtherNet\/IP).\u003c\/li\u003e\n\u003cli\u003eLarge-scale distributed manufacturing lines requiring fiber-optic backbones.\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure sectors demanding IEC 62443 cybersecurity standards.\u003c\/li\u003e\n\u003cli\u003eControl room and localized machine-level networking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5213-3BD00-2TB2 (XB213-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13x RJ45, 3x MM FO SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to +60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.57 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.00 cm x 10.90 cm x 11.70 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap the unit onto a standard 35mm DIN rail. Ensure adequate space around the device for heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Connect redundant power supplies to the designated terminals to ensure uninterrupted operation. Verify voltage matches the device requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use shielded Cat5e or Cat6 cables for RJ45 ports to minimize EMI. Ensure FO SC connectors are kept clean and handled according to fiber optic best practices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Use the console port or web-based interface to complete the initial setup and security hardening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the ambient temperature remains within the 0 Celsius to +60 Celsius specification to prevent thermal-related performance degradation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779176299,"sku":"6GK5213-3BD00-2TB2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5213-3bd00-2tb2-j2ftfpxq2cg_969b8248-74e5-44a7-9f1e-0ee4694de06c.jpg?v=1767089468"},{"product_id":"siemens-6gk5213-3bb00-2tb2-scalance-xb213-3-managed-layer-2-ie-switch","title":"Siemens 6GK5213-3BB00-2TB2 SCALANCE XB213-3 Managed Layer 2 IE Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6GK5213-3BB00-2TB2\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE XB213-3\u003c\/strong\u003e managed Layer 2 Industrial Ethernet switch designed for robust industrial communication networks. This module features 13x 10\/100 Mbps RJ45 ports and 3x Multi-Mode Fiber Optic (MM FO) ST ports, providing versatile connectivity options. It includes a console port for configuration, diagnostics LEDs for operational status monitoring, and supports a redundant power supply for enhanced reliability. Certified to IEC 62443-4-2, the switch operates within a temperature range of 0 degC to +60 degC and is designed for mounting onto a standard rail, with default support for EtherNet\/IP.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManaged Layer 2 Industrial Ethernet Switch functionality\u003c\/li\u003e\n  \u003cli\u003e13x 10\/100 Mbps RJ45 ports\u003c\/li\u003e\n  \u003cli\u003e3x Multi-Mode Fiber Optic (MM FO) ST ports\u003c\/li\u003e\n  \u003cli\u003e1x Console port for configuration\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostics LED indicators\u003c\/li\u003e\n  \u003cli\u003eSupport for redundant power supply\u003c\/li\u003e\n  \u003cli\u003eIEC 62443-4-2 certified for cybersecurity\u003c\/li\u003e\n  \u003cli\u003eDefault EtherNet\/IP protocol support\u003c\/li\u003e\n  \u003cli\u003eDesigned for standard rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial automation networks requiring managed Layer 2 switching\u003c\/li\u003e\n  \u003cli\u003eDistributed control systems (DCS) and SCADA systems\u003c\/li\u003e\n  \u003cli\u003eMachine building and plant engineering\u003c\/li\u003e\n  \u003cli\u003eApplications requiring fiber optic connectivity for extended distances or electrical isolation\u003c\/li\u003e\n  \u003cli\u003eEnvironments demanding cybersecurity compliance for network components\u003c\/li\u003e\n  \u003cli\u003eIntegration into EtherNet\/IP-based control architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrands\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSCALANCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType of Product\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAccessories\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePort Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e13x 10\/100 Mbps RJ45, 3x MM FO ST, 1x Console\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRedundant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 degC to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStandard Rail\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDefault Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEtherNet\/IP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCertification\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIEC 62443-4-2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12.00 x 10.90 x 11.70 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.56 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5A002\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all power to the installation area is de-energized before mounting or connecting the device.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the SCALANCE XB213-3 switch onto a standard DIN rail in a suitable industrial enclosure, ensuring adequate ventilation.\u003c\/li\u003e\n  \u003cli\u003eConnect the required 10\/100 Mbps RJ45 Ethernet cables to the respective ports, ensuring proper cable routing and strain relief.\u003c\/li\u003e\n  \u003cli\u003eFor fiber optic connections, connect Multi-Mode Fiber Optic (MM FO) ST cables to the designated ports, observing proper fiber handling procedures.\u003c\/li\u003e\n  \u003cli\u003eConnect the console cable to the console port for initial configuration or diagnostic access, if required.\u003c\/li\u003e\n  \u003cli\u003eConnect the redundant power supply leads to the designated terminals, observing correct polarity and ensuring secure connections.\u003c\/li\u003e\n  \u003cli\u003eVerify all connections are firm and correctly seated before re-energizing the system.\u003c\/li\u003e\n  \u003cli\u003eObserve the diagnostics LEDs to confirm proper power-up and network link status after power restoration.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 62443-4-2:\u003c\/strong\u003e Certified for cybersecurity for industrial automation and control systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779700587,"sku":"6GK5213-3BB00-2TB2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5213-3bb00-2tb2-hbx0nenv5cw_89e07314-c1e8-4228-95b2-199ee8ca0fae.jpg?v=1767089487"},{"product_id":"siemens-6gk5788-1gd00-0aa0-scalance-w788-1-iwlan-access-point","title":"Siemens 6GK5788-1GD00-0AA0 SCALANCE W788-1 IWLAN Access Point","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK5788-1GD00-0AA0\u003c\/strong\u003e is an industrial-grade \u003cstrong\u003eSCALANCE W788-1 M12\u003c\/strong\u003e IWLAN access point engineered for robust wireless networking in demanding production environments. This communication module supports \u003cstrong\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/strong\u003e wireless standards, operating in both 2.4 GHz and 5 GHz frequency bands to provide reliable connectivity for automated production lines. It features a single radio module, three N-CON antenna ports, and an M12 A-coded Ethernet interface capable of data transmission speeds up to 1 Gbit\/s. Designed for resilience, the unit includes an IP65-rated housing for protection against dust and moisture, as well as support for \u003cstrong\u003ePower over Ethernet (PoE)\u003c\/strong\u003e and redundant 24 V DC power inputs to ensure operational continuity.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IEEE 802.11a\/b\/g\/h\/n wireless standards.\u003c\/li\u003e\n\u003cli\u003eDual-band operation: 2.4 GHz and 5 GHz.\u003c\/li\u003e\n\u003cli\u003eGross data rate up to 450 Mbit\/s per radio.\u003c\/li\u003e\n\u003cli\u003e1x M12 Ethernet port (up to 1 Gbit\/s).\u003c\/li\u003e\n\u003cli\u003e3x N-CON antenna ports for external antenna connectivity.\u003c\/li\u003e\n\u003cli\u003eRedundant 24 V DC power supply and PoE support.\u003c\/li\u003e\n\u003cli\u003eIP65-rated enclosure for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eSupport for Key-Plug accessories for expanded iFeatures.\u003c\/li\u003e\n\u003cli\u003eWPA2\/802.11i\/e security protocols for data protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated production and assembly lines.\u003c\/li\u003e\n\u003cli\u003eIndustrial wireless infrastructure for mobile equipment.\u003c\/li\u003e\n\u003cli\u003eRemote monitoring and data acquisition in harsh environments.\u003c\/li\u003e\n\u003cli\u003eHigh-speed wireless integration for industrial control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIWLAN Access Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.11a\/b\/g\/h\/n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Bands\u003c\/td\u003e\n\u003ctd\u003e2.4 GHz \/ 5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Data Rate\u003c\/td\u003e\n\u003ctd\u003e450 Mbit\/s per radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e1x M12, 1 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC \/ PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eWPA2\/802.11i\/e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e0.10 x 0.10 x 0.10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the device is mounted in an environment consistent with the -20 degC to +60 degC temperature rating.\u003c\/li\u003e\n\u003cli\u003eUse the provided M12 sealing caps on all unused M12 connectors to maintain the IP65 rating.\u003c\/li\u003e\n\u003cli\u003eConnect the redundant 24 V DC power supply to the designated terminals to ensure uninterruptible power.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the housing to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eWhen using external antennas, ensure they are connected to the N-CON ports with appropriate coaxial cabling to minimize signal loss.\u003c\/li\u003e\n\u003cli\u003eConfigure the unit via the plug slot if utilizing additional Key-Plug iFeatures.\u003c\/li\u003e\n\u003cli\u003eVerify local regulatory compliance for wireless operations, as this model is intended for use outside of the USA and Israel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779831659,"sku":"6GK5788-1GD00-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5788-1gd00-0aa0-3kpkmuazr0s_3dd6e117-5862-480e-aa27-7242258dd9eb.jpg?v=1767089493"},{"product_id":"siemens-6gk5224-0ba00-2aa3-scalance-x224-managed-industrial-ethernet-switch","title":"Siemens 6GK5224-0BA00-2AA3 SCALANCE X224 Managed Industrial Ethernet Switch","description":"\u003cp\u003eThe \u003cstrong\u003e6GK5224-0BA00-2AA3\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X224\u003c\/strong\u003e managed industrial Ethernet switch, designed to provide high-density connectivity and robust network management for complex automation systems. Featuring 24 x 10\/100 Mbit\/s RJ45 ports, this switch is optimized for reliable data exchange in production environments. It supports advanced features such as PROFINET IO device compatibility, redundant power supply capabilities, and the ability to operate within redundant ring topologies for maximum network availability. Maintenance is streamlined through integrated LED diagnostics and an error-signaling contact with an accessible set button, while the optional C-PLUG allows for simplified configuration storage and device swapping.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Port Density:\u003c\/strong\u003e 24 x 10\/100 Mbit\/s RJ45 ports for extensive device integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Supports operation in redundant ring topologies to prevent network downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Integrated LED status indicators and error-signaling contact for proactive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Management:\u003c\/strong\u003e PROFINET IO device compliant with full network management capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Power:\u003c\/strong\u003e Redundant power supply input to ensure continuous operation during power faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance:\u003c\/strong\u003e Optional C-PLUG support for quick configuration backup and deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale production floor networking.\u003c\/li\u003e\n\u003cli\u003ePROFINET-based automation and drive control systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial environments requiring redundant network topologies.\u003c\/li\u003e\n\u003cli\u003eInfrastructure where real-time diagnostics and high port counts are critical.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e24 x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Features\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO, Redundancy Manager, VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant power input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.80 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 cm x 12.40 cm x 12.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003e5A002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for standard DIN rail mounting or wall mounting. Ensure the installation area allows for adequate heat dissipation around the chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Configuration:\u003c\/strong\u003e When setting up a redundant ring, ensure all switches in the ring are configured to support the redundancy manager protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Connect redundant power sources to the dedicated terminals to enable the switch's failover protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Test the error-signaling contact during commissioning to ensure that control room alarms trigger correctly if a fault is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-PLUG:\u003c\/strong\u003e Insert the optional C-PLUG before commissioning to ensure network configuration is automatically backed up to the external memory.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779897195,"sku":"6GK5224-0BA00-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5224-0ba00-2aa3-nwoi3sjrxky_a2701966-6324-4d91-b9f5-cf0387344bc6.jpg?v=1767089496"},{"product_id":"siemens-6gk5408-2fd00-2aa2-scalance-x408-2-industrial-ethernet-switch","title":"Siemens 6GK5408-2FD00-2AA2 SCALANCE X408-2 Industrial Ethernet Switch","description":"\u003cp\u003eThe \u003cstrong\u003e6GK5408-2FD00-2AA2\u003c\/strong\u003e is a \u003cstrong\u003eSCALANCE X408-2\u003c\/strong\u003e modular industrial Ethernet switch, designed to provide high-performance networking and advanced management capabilities in rugged production environments. This switch features a hybrid port configuration, including four 10\/100\/1000 Mbit\/s RJ45 ports and four 10\/100 Mbit\/s RJ45 ports, alongside two additional slots for Gigabit or Fast Ethernet media modules. Engineered for reliability, the \u003cstrong\u003e6GK5408-2FD00-2AA2\u003c\/strong\u003e includes an integrated redundancy manager and supports standard IT protocols such as RSTP and VLAN, enabling sophisticated network segmentation and high availability. It is supplied with a C-PLUG, which allows for rapid configuration backups and seamless device replacement, minimizing downtime in critical automation systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Port Density:\u003c\/strong\u003e Combination of Gigabit and Fast Ethernet RJ45 ports for versatile device connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Expansion:\u003c\/strong\u003e Two media module slots allow for customized network connectivity (Fiber\/Copper).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Reliability:\u003c\/strong\u003e Integrated redundancy manager supports fault-tolerant network topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Management:\u003c\/strong\u003e Supports VLAN (Virtual LAN) and RSTP (Rapid Spanning Tree Protocol) for efficient traffic management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Maintenance:\u003c\/strong\u003e Includes a C-PLUG for fast, error-free device swapping and configuration storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-availability industrial network backbones.\u003c\/li\u003e\n\u003cli\u003eIntegration of office-level communication protocols into the factory floor.\u003c\/li\u003e\n\u003cli\u003eReal-time data transmission in multi-machine production lines.\u003c\/li\u003e\n\u003cli\u003eDistributed control architectures requiring modular media flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSIMATIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X408-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed Ports\u003c\/td\u003e\n\u003ctd\u003e4 x 10\/100\/1000 Mbit\/s, 4 x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd\u003e2 x Gigabit\/Fast Ethernet Media Module Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Features\u003c\/td\u003e\n\u003ctd\u003eRSTP, VLAN, Redundancy Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Tool\u003c\/td\u003e\n\u003ctd\u003eC-PLUG (Included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24.20 cm x 11.70 cm x 14.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for mounting on a standard S7-300 profile rail or direct wall mounting. Ensure sufficient clearance for airflow to prevent overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e Configure the integrated redundancy manager to ensure path protection in ring topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia Modules:\u003c\/strong\u003e When installing media modules, ensure the power is off to avoid electrical damage to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-PLUG Usage:\u003c\/strong\u003e Insert the C-PLUG into the provided slot before initial startup to ensure configuration data is stored correctly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Always connect the chassis to the system grounding point to maintain EMC integrity and protect against surge currents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716779995499,"sku":"6GK5408-2FD00-2AA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5408-2fd00-2aa2-3z0jeknqln2_3bbfd9a0-cdaf-40ca-b9f4-eab830b8eb58.jpg?v=1767089500"},{"product_id":"siemens-simatic-net-cp-343-1-it-communication-processor-6gk7343-1gx00-0xe0","title":"Siemens SIMATIC NET CP 343-1 IT Communication Processor (6GK7343-1GX00-0XE0)","description":"\u003cp\u003eDescription\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK7343-1GX00-0XE0\u003c\/strong\u003e is an industrial communication processor from the \u003cstrong\u003eSIMATIC NET\u003c\/strong\u003e portfolio, designed specifically for the \u003cstrong\u003eSIMATIC S7-300\u003c\/strong\u003e PLC family. This \"IT\" variant of the CP 343-1 allows S7-300 controllers to interface with Industrial Ethernet networks using both ISO and TCP\/IP protocols. Beyond standard data exchange, this module includes advanced functionality such as integrated web server capabilities and email alert generation, making it a powerful tool for remote diagnostics and factory-to-office communication.\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connectivity:\u003c\/strong\u003e 10\/100 Mbit\/s interface for Industrial Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e Comprehensive support for S7 communication, Fetch\/Write, and Send\/Receive protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIT Functionality:\u003c\/strong\u003e Includes integrated web server (WWW) and email notification services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless S7-300 Integration:\u003c\/strong\u003e Designed for high-performance communication within the S7-300 backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Versatility:\u003c\/strong\u003e Ideal for plant-wide data integration and remote monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003eNET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6GK7343-1GX00-0XE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet (ISO \u0026amp; TCP\/IP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.58kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.70 x 11.60 x 6.90 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLM Product Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eInstallation Guidelines\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating:\u003c\/strong\u003e Ensure the S7-300 CPU rack power is disconnected before installing the communication processor to avoid shorting the backplane pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use shielded RJ45 Industrial Ethernet cables to ensure reliable data transfer in electrically noisy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize Siemens STEP 7 software to configure the network parameters (IP address, subnet, gateway) and communication blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e Ensure the module is installed in a well-ventilated enclosure to maintain safe operating temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb\/IT Setup:\u003c\/strong\u003e For web server or email functions, verify that the network security settings are configured properly to prevent unauthorized access to the controller\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716780781931,"sku":"6GK7343-1GX00-0XE0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk7343-1gx00-0xe0-bkw5r31z5im_bc74d52d-d47c-49f8-97d1-49628f4a9886.jpg?v=1767089532"},{"product_id":"siemens-6gk1502-3cc10-simatic-net-optical-link-module","title":"Siemens 6GK1502-3CC10 SIMATIC NET Optical Link Module","description":"\u003cp\u003eThe \u003cstrong\u003e6GK1502-3CC10\u003c\/strong\u003e is an industrial \u003cstrong\u003eOptical Link Module (OLM\/G12-1300 V3.1)\u003c\/strong\u003e designed to bridge RS485 electrical signals with fiber optic media in PROFIBUS networks. This \u003cstrong\u003ecommunication module\u003c\/strong\u003e facilitates long-distance data transmission by converting standard electrical signals into optical pulses, utilizing a 1300 nm wavelength for reliable performance over glass fiber optic cables. It features two integrated interfaces for fiber optic connections using four BFOC sockets, allowing for redundant or linear network topologies. The module includes an integrated signal contact for status monitoring and a dedicated measurement output for diagnostics, ensuring consistent network availability in complex industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e One RS485 interface for PROFIBUS connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Connectivity:\u003c\/strong\u003e Two interfaces for glass fiber optic cables (4 x BFOC sockets).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength:\u003c\/strong\u003e 1300 nm for extended transmission distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Integrated signal contact and measurement output for network monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for use with SIMATIC NET and standard PROFIBUS systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLong-distance PROFIBUS data transmission.\u003c\/li\u003e\n\u003cli\u003eIndustrial networking in environments with high electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eBackbone connectivity for distributed I\/O and controller systems.\u003c\/li\u003e\n\u003cli\u003eFactory automation and process control installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eSimatic S5 \/ NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6GK1502-3CC10 (OLM\/G12-1300 V3.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Interface\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Optic Interface\u003c\/td\u003e\n\u003ctd\u003e2 (4 x BFOC sockets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWave Length\u003c\/td\u003e\n\u003ctd\u003e1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.20 x 5.10 x 15.20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eEAR99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9-pin Sub-D\u003c\/td\u003e\n\u003ctd\u003eRS485 PROFIBUS connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBFOC Socket (x4)\u003c\/td\u003e\n\u003ctd\u003eGlass Fiber Optic connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003eSignal contact \/ Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e The module is designed for standard DIN rail mounting; ensure a secure mechanical lock before connecting cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain proper chassis grounding to minimize interference and ensure stable signal transmission on the RS485 link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e When using glass fiber cables, adhere to the minimum bend radius specifications to prevent signal attenuation or fiber damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI\/RFI Mitigation:\u003c\/strong\u003e Keep fiber optic cables routed away from high-voltage power lines to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Utilize the signal contact output to trigger alarms on external PLC inputs in the event of a fiber link failure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716781338987,"sku":"6GK1502-3CC10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1502-3cc10-aurq0ot2tvu_060e1d3d-4782-471a-828d-7cb6cede8c7d.jpg?v=1767089552"},{"product_id":"siemens-6gk1561-3aa01-simatic-net-cp-5613-a2-communications-processor","title":"Siemens 6GK1561-3AA01 SIMATIC NET CP 5613 A2 Communications Processor","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK1561-3AA01 is a CP 5613 A2 communications processor designed for legacy industrial automation systems. This module is implemented as a \u003cstrong\u003ePCI card\u003c\/strong\u003e, providing a direct and reliable connection to \u003cstrong\u003ePROFIBUS\u003c\/strong\u003e networks. It features a DP-RAM interface specifically for \u003cstrong\u003eDP master\u003c\/strong\u003e operations and offers support for both \u003cstrong\u003ePG and FDL protocols\u003c\/strong\u003e. This unit is intended for established applications running on operating systems up to Windows XP. The package includes the necessary DP-Base software, configuration tools, and runtime software on a CD-ROM. For systems requiring support for operating systems newer than Windows XP, the successor model 6GK1561-3AA02 is recommended.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003ePCI card form factor for integration into industrial PCs.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eEnables PROFIBUS network connectivity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eFunctions as a PROFIBUS DP master.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSupports PG and FDL communication protocols.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eIncludes DP-Base software, configuration tool, and runtime software.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSingle license for one installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eLegacy manufacturing and production lines.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eProcess control systems requiring PROFIBUS DP master capabilities.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003ePC-based automation and control stations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eData acquisition and monitoring systems on older platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 300px;\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc; color: #2d3748; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePart Number\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e6GK1561-3AA01\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Series\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC NET\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommunications Processor (CP 5613 A2)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eForm Factor\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePCI Card\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eNetwork Connectivity\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePROFIBUS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSupported Protocols\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDP (Master), PG, FDL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eInterface\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDP-RAM\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSoftware Included\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eDP-Base, Configuration Tool, Runtime Software\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSupported Operating Systems\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eUp to Windows XP (Legacy applications only)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePhase-Out\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e0.60 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e12.70 x 5.10 x 17.80 cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e85176200\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eECCN\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eEAR99\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Calculated)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0; color: #c53030; font-weight: bold;\"\u003eCRITICAL WARNING: Electrical Hazard\u003c\/p\u003e\n    \u003cp style=\"margin: 8px 0 0 0; color: #2d3748;\"\u003eDisconnect all power from the host computer and follow all Lockout\/Tagout (LOTO) procedures before opening the chassis or handling the module. Failure to de-energize the system can result in severe electrical shock, equipment damage, and personal injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e1\u003c\/span\u003e\n        \u003c\/span\u003e\n        Ensure the host PC is fully de-energized and disconnected from its power source. Verify zero energy state.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e2\u003c\/span\u003e\n        \u003c\/span\u003e\n        Use a properly grounded electrostatic discharge (ESD) wrist strap and connect it to an unpainted metal surface of the computer chassis to prevent static damage to the card.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e3\u003c\/span\u003e\n        \u003c\/span\u003e\n        Open the computer chassis and select a vacant, compatible PCI slot. Remove the corresponding metal slot cover from the back of the chassis.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e4\u003c\/span\u003e\n        \u003c\/span\u003e\n        Carefully align the card's edge connector with the PCI slot and press down firmly and evenly until the card is fully seated.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e5\u003c\/span\u003e\n        \u003c\/span\u003e\n        Secure the card's metal mounting bracket to the chassis using the screw removed from the slot cover.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e6\u003c\/span\u003e\n        \u003c\/span\u003e\n        Connect the PROFIBUS network cable to the port on the card's bracket. Ensure the connector is securely fastened.\n    \u003c\/li\u003e\n    \u003cli style=\"position: relative; padding-left: 40px; margin-bottom: 12px; counter-increment: step-counter;\"\u003e\n        \u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold;\"\u003e\n            \u003cspan style=\"font-size: 14px;\"\u003e7\u003c\/span\u003e\n        \u003c\/span\u003e\n        Replace the computer chassis cover, reconnect power, and proceed with software installation and configuration.\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716781928811,"sku":"6GK1561-3AA01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1561-3aa01-nzoohvkjf4m_c72b2ad8-1085-446a-a7e3-ee4ba5d14830.jpg?v=1767089574"},{"product_id":"siemens-6gk1411-5aa00-simatic-net-ie-pb-link","title":"Siemens 6GK1411-5AA00 SIMATIC NET IE\/PB Link","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK1411-5AA00\u003c\/strong\u003e is a specialized \u003cstrong\u003eSIMATIC NET IE\/PB Link\u003c\/strong\u003e gateway designed to facilitate seamless protocol transition between \u003cstrong\u003eIndustrial Ethernet\u003c\/strong\u003e and \u003cstrong\u003ePROFIBUS\u003c\/strong\u003e networks. This module integrates \u003cstrong\u003ePROFINET\u003c\/strong\u003e functionality, allowing for high-performance communication across heterogeneous network architectures. It supports \u003cstrong\u003eTCP\/IP\u003c\/strong\u003e communication, \u003cstrong\u003eS7 routing\u003c\/strong\u003e, and \u003cstrong\u003edata record routing\u003c\/strong\u003e, enabling transparent access to PROFIBUS devices from an Ethernet-based controller or HMI. With a 10\/100 Mbit Fast Ethernet interface and a PROFIBUS DP interface capable of speeds from 9.6 to 12 Mbit\/s, this link provides a critical bridge for modernizing legacy systems and expanding complex industrial automation networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGateway Functionality:\u003c\/strong\u003e Enables transition between Industrial Ethernet and PROFIBUS networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET Integration:\u003c\/strong\u003e Full support for PROFINET IO and controller functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Capabilities:\u003c\/strong\u003e Advanced S7 routing and data record routing for cross-network data exchange.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Performance:\u003c\/strong\u003e 10\/100 Mbit\/s Fast Ethernet port and auto-detecting PROFIBUS interface up to 12 Mbit\/s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability:\u003c\/strong\u003e Engineered for industrial-grade communication with robust protocol handling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBridging Ethernet-based SCADA\/HMI systems with existing PROFIBUS DP fieldbus segments.\u003c\/li\u003e\n\u003cli\u003eCross-network data acquisition in distributed automation environments.\u003c\/li\u003e\n\u003cli\u003eModernization and retrofitting projects requiring IP-based access to legacy PROFIBUS instrumentation.\u003c\/li\u003e\n\u003cli\u003eComplex S7 communication routing for multi-controller systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6GK1411-5AA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module (IE\/PB Link)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS Interface\u003c\/td\u003e\n\u003ctd\u003e9.6 kbit\/s to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, PROFINET, S7 Routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.80 x 15.20 x 10.20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for standard mounting within a control cabinet, typically on a S7-300 profile rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Ensure high-quality shielded PROFIBUS cables are used to maintain 12 Mbit\/s signal integrity. Connect Ethernet via standard RJ45 Cat5e or higher cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize STEP 7 or TIA Portal for network configuration and routing table setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Assignment:\u003c\/strong\u003e Verify that PROFIBUS station addresses do not conflict with existing field devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure a solid connection to the functional earth of the cabinet to protect the communication circuitry from EMI\/RFI.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716783075691,"sku":"6GK1411-5AA00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk1411-5aa00-bq1ppgbtiho_448251da-e4b2-4361-8c73-b22eae5af6b2.jpg?v=1767089620"},{"product_id":"siemens-6gk5202-2bb00-2ba3-scalance-x202-2irt-managed-switch","title":"Siemens 6GK5202-2BB00-2BA3 SCALANCE X202-2IRT Managed Switch","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e6GK5202-2BB00-2BA3\u003c\/strong\u003e is a managed \u003cstrong\u003eSCALANCE X202-2IRT\u003c\/strong\u003e Industrial Ethernet switch, engineered for high-performance Isochronous Real-Time (IRT) communication in demanding automation networks. It is equipped with two 10\/100 Mbit\/s \u003cstrong\u003eRJ45 ports\u003c\/strong\u003e and two 100 Mbit\/s \u003cstrong\u003emultimode BFOC (ST) fiber optic ports\u003c\/strong\u003e, providing versatile media connectivity for copper and fiber infrastructures. Designed for mission-critical reliability, it supports redundant power supplies and features an integrated \u003cstrong\u003eRedundancy Manager\u003c\/strong\u003e to ensure seamless network recovery. The device functions as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e and includes robust network management features, an error signaling contact with a set button, and optional \u003cstrong\u003eC-plug\u003c\/strong\u003e support for simplified configuration and device replacement.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia Flexibility:\u003c\/strong\u003e 2x RJ45 (10\/100 Mbit\/s) and 2x Multimode BFOC fiber optic ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Reliability:\u003c\/strong\u003e Integrated Redundancy Manager for rapid failover and redundant power supply inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Performance:\u003c\/strong\u003e Optimized for PROFINET IRT applications requiring deterministic communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Error signaling contact with manual set button for immediate network fault notification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Support for C-plug for convenient data storage and device swapping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePROFINET-based industrial automation networks\u003c\/li\u003e\n\u003cli\u003eHigh-availability motion control systems\u003c\/li\u003e\n\u003cli\u003eIndustrial backbones requiring fiber optic long-distance connectivity\u003c\/li\u003e\n\u003cli\u003eEnvironments demanding deterministic real-time data exchange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSCALANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6GK5202-2BB00-2BA3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eManaged IE IRT Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts (RJ45)\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts (Fiber)\u003c\/td\u003e\n\u003ctd\u003e2 x 100 Mbit\/s Multimode BFOC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.00 x 12.40 x 12.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003e5A002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for standard DIN rail or wall mounting within an industrial control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowering:\u003c\/strong\u003e Connect redundant power supplies to the designated terminals to maintain network availability during a single power source failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the switch chassis is correctly connected to the common system ground to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Handling:\u003c\/strong\u003e When connecting BFOC fiber cables, ensure the connectors are clean and free of dust to maintain signal integrity; avoid bending cables beyond the specified radius.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize the C-plug for automated configuration backup, which allows for fast device replacement without needing manual network parameter re-entry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716783108459,"sku":"6GK5202-2BB00-2BA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5202-2bb00-2ba3-4d320jjmu4y_3277b5ad-1c66-444a-a3c4-3d77fe2aa677.jpg?v=1767089623"}],"url":"https:\/\/www.plcprotech.com\/hu\/collections\/siemens-industrial-net-power.oembed?page=3","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}