{"product_id":"bently-nevada-330103-00-10-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-00-10-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eA metric thread profile of M10 x 1 without armor (base model 330103) featuring 0 mm unthreaded length (Option 00) and a 100 mm overall case length (Option 10) defines the configuration of the \u003cstrong\u003eBently Nevada 330103-00-10-10-02-05 3300 XL 8 mm proximity probe\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis eddy-current non-contacting displacement probe is a critical sensor used in 3300 XL 8 mm monitoring chains to deliver precise shaft vibration and axial position measurements. It interfaces directly with a 3300 XL extension cable and a 3300 XL Proximitor sensor. Unlike other configurations with protective armor, this unarmored standard coaxial variant is designed for routing inside protected dry-conduit environments or internal machine housings where external mechanical abrasion is minimized. The probe system utilizes Option 02 (standard coaxial cable with a miniature ClickLoc connector) and Option 05 (CSA, ATEX, and IECEx approvals) to ensure high-accuracy performance and certified operations in hazardous environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM10 x 1 metric threaded probe body without armor provides standard mounting compatibility in metric installations.\u003c\/li\u003e\n  \u003cli\u003eOption 00 specifies a 0 mm unthreaded length, allowing maximum thread engagement inside the bracket or machine housing.\u003c\/li\u003e\n  \u003cli\u003eOption 10 specifies a 100 mm overall case length, providing sufficient depth for internal machine clearances.\u003c\/li\u003e\n  \u003cli\u003eOption 10 specifies a 1.0 meter (3.3 feet) total cable length, suitable for short-reach local junctions or connection to extension cables.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a gold-plated coaxial ClickLoc connector with standard FEP jacket cable.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides CSA, ATEX, and IECEx agency approvals for intrinsic safety and non-sparking installations.\u003c\/li\u003e\n  \u003cli\u003eHigh-stability polyphenylene sulfide (PPS) probe tip ensures robust resistance against corrosive fluids and extreme temperature cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and dynamic motion analysis in heavy-duty turbomachinery.\u003c\/li\u003e\n  \u003cli\u003eThrust position and rotor axial displacement tracking on industrial gas turbines, steam turbines, and centrifugal compressors.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection and condition-based monitoring systems in oil, gas, chemical processing, power plants, and maritime operations.\u003c\/li\u003e\n  \u003cli\u003eShaft positioning and bearing clearance monitoring in large-scale gearboxes, electric motors, and pumps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330103-00-10-10-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, metric M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e100 mm case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-00-10-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Profile\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1 (metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical Armor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Resistance (R_PROBE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms nominal (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal when combined with system parts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalibration Target Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e303 or 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring (designed to seal differential pressure)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Thread Engagement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Component\u003c\/th\u003e\n      \u003cth\u003eSignal Designation\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCenter Conductor\u003c\/td\u003e\n      \u003ctd\u003eHigh-frequency RF Signal \/ DC Bias Voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Conductor Shield\u003c\/td\u003e\n      \u003ctd\u003eSignal Return \/ Shield Ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways observe the maximum thread engagement limit of 15 mm for the M10 x 1 thread to avoid binding or housing damage during mounting.\u003c\/li\u003e\n  \u003cli\u003eTighten the gold-plated ClickLoc connector finger-tight only. Do not use pliers on these standard gold connectors to avoid crushing or strip damage.\u003c\/li\u003e\n  \u003cli\u003eFor proper transducer sensitivity, verify the probe tip is gapped near the center of its linear range, typically 1.27 mm (50 mils) or roughly -10 Vdc bias output voltage.\u003c\/li\u003e\n  \u003cli\u003eEnsure that probe cables are physically isolated and routed inside robust electrical conduit systems when run through turbulent or oil-rich environments.\u003c\/li\u003e\n  \u003cli\u003eAvoid installing or operating the probe in environments below -34 degC to protect the Viton pressure seal from structural failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA Certified: Class I, Zone 0, Ex ia IIC T5...T1 Ga; Class I, Division 1, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003eATEX Certified: Group II 1 G, Ex ia IIC T5...T1 Ga; Group II 3 G, Ex nA\/ec IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003eIECEx Certified: Ex ia IIC T5...T1 Ga; Ex nA\/ec IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666622247275,"sku":"330103-00-10-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-10-10-02-05-3300-xl-8-mm-proximitor-sensor-ti2mrimbf3s_1376fdb0-7471-42a5-9175-3622cfbee2d9.jpg?v=1765444277","url":"https:\/\/www.plcprotech.com\/hu\/products\/bently-nevada-330103-00-10-10-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}