{"product_id":"siemens-6gk5216-0ha00-2as6-scalance-xp216-managed-industrial-ethernet-switch","title":"Siemens 6GK5216-0HA00-2AS6 SCALANCE XP216 Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5216-0HA00-2AS6 is a managed Industrial Ethernet switch from the SCALANCE XP216 series, designed for reliable network management in demanding industrial environments. This device provides a total of 16 ports, including \u003cstrong\u003e12 x 10\/100 Mbps M12 ports\u003c\/strong\u003e and \u003cstrong\u003e4 x 10\/100\/1000 Mbps M12 ports\u003c\/strong\u003e for versatile connectivity. Engineered for harsh conditions, the switch features a rugged enclosure with an \u003cstrong\u003eIP65 protection rating\u003c\/strong\u003e and supports redundant power supplies for high operational availability. It functions as a \u003cstrong\u003ePROFINET IO device\u003c\/strong\u003e and is certified to \u003cstrong\u003eIEC 62443-4-2\u003c\/strong\u003e, ensuring compliance with modern industrial cybersecurity standards.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManaged Layer 2 Industrial Ethernet switch\u003c\/li\u003e\n  \u003cli\u003e12 x 10\/100 Mbps ports with M12 connectors\u003c\/li\u003e\n  \u003cli\u003e4 x 10\/100\/1000 Mbps ports with M12 connectors\u003c\/li\u003e\n  \u003cli\u003eIP65-rated enclosure for protection against dust and water ingress\u003c\/li\u003e\n  \u003cli\u003eFunctions as a PROFINET IO device for seamless automation integration\u003c\/li\u003e\n  \u003cli\u003eSupports redundant ring operation for network fault tolerance\u003c\/li\u003e\n  \u003cli\u003eRedundant power supply input for increased system uptime\u003c\/li\u003e\n  \u003cli\u003eIntegrated LED diagnostics for at-a-glance status monitoring\u003c\/li\u003e\n  \u003cli\u003eIncludes an error signaling contact for external fault indication\u003c\/li\u003e\n  \u003cli\u003eCertified according to IEC 62443-4-2 for industrial security\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine building and factory automation\u003c\/li\u003e\n  \u003cli\u003eAutomotive manufacturing and assembly lines\u003c\/li\u003e\n  \u003cli\u003eTransportation systems (rail, traffic control)\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing plants\u003c\/li\u003e\n  \u003cli\u003eApplications requiring cabinet-free, decentralized networking\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold; background-color: #f7fafc;\"\u003eCategory\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px; background-color: #f7fafc;\"\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eSCALANCE XP216\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e6GK5216-0HA00-2AS6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eTotal Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eFast Ethernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e12 x 10\/100 Mbps, M12 D-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eGigabit Ethernet Ports\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e4 x 10\/100\/1000 Mbps, M12 X-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eIndustrial Protocol Support\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003ePROFINET IO Device\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eSecurity Certification\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eIEC 62443-4-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eActive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e0.50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e85176200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e5A002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 12px 16px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 12px 16px;\"\u003e28.0 x 20.0 x 4.9 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 24px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages can cause electric shock and burns. Disconnect, lock out, and tag out all power sources before installing or servicing this equipment. Installation must be performed by qualified personnel only.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before installation, ensure all related power sources to the control panel or mounting location are completely de-energized, locked out, and tagged out according to site safety procedures.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount the Switch:\u003c\/strong\u003e Securely mount the SCALANCE XP216 switch to a stable, flat surface or DIN rail (if an adapter is used) in its intended operational environment. Ensure adequate clearance for cable routing and heat dissipation.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Protective Earth (PE):\u003c\/strong\u003e Connect a low-impedance protective earthing conductor to the designated grounding terminal on the switch chassis. A proper ground connection is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eTerminate Power Supplies:\u003c\/strong\u003e Connect the primary and, if used, redundant power supply cables to the M12 power connector. Verify the voltage and polarity match the device's specifications before connection.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Network Cables:\u003c\/strong\u003e Connect the Ethernet cables to the appropriate M12 ports. Ensure connectors are fully seated and tightened to the manufacturer's recommended torque to maintain the IP65 rating. Use the included dust caps for any unused ports.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Signaling Contact:\u003c\/strong\u003e If required, connect the wiring for the error signaling contact to the designated terminals. This allows for remote monitoring of the switch's health status.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e7\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePower On and Verify:\u003c\/strong\u003e After removing all locks and tags, re-energize the system. Observe the device's LEDs to confirm correct power-up, network link status, and activity.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716769575275,"sku":"6GK5216-0HA00-2AS6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5216-0ha00-2as6-yetjjxaiwpz_de27f7f4-df83-4157-95e9-f2f3c02c2e36.jpg?v=1767089132","url":"https:\/\/www.plcprotech.com\/hu\/products\/siemens-6gk5216-0ha00-2as6-scalance-xp216-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}