{"product_id":"triconex-3624-tmr-supervised-digital-output-module","title":"Triconex 3624 TMR Supervised Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTriconex 3624\u003c\/strong\u003e is a \u003cstrong\u003e24 VDC TMR supervised digital output module\u003c\/strong\u003e for Tricon fault-tolerant control systems. It provides 16 commoned digital output points for controlling field devices in critical process applications.\u003c\/p\u003e\n\n\u003cp\u003eThe module receives output data from the three Tricon Main Processors through separate channels. Each set of three output signals is processed by a fully fault-tolerant quadruplicated output switch before being sent to the field termination.\u003c\/p\u003e\n\n\u003cp\u003eVoltage and current loopback circuits continuously verify the output switches, field circuit, and connected load. These diagnostics operate without changing the commanded output state.\u003c\/p\u003e\n\n\u003cp\u003eThe supervision circuitry detects loss of field power, open loads, missing loads, shorted loads, and field shorts that could energize a load incorrectly. The module supports hot-spare operation and requires a separate external termination panel.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTriple Modular Redundant output architecture\u003c\/li\u003e\n\u003cli\u003eFully fault-tolerant quadruplicated output switching\u003c\/li\u003e\n\u003cli\u003eTwo-out-of-three output voting\u003c\/li\u003e\n\u003cli\u003eVoltage and current loopback diagnostics\u003c\/li\u003e\n\u003cli\u003eContinuous field circuit and load supervision\u003c\/li\u003e\n\u003cli\u003eDetection of open, missing, and shorted loads\u003c\/li\u003e\n\u003cli\u003eDetection of field power loss\u003c\/li\u003e\n\u003cli\u003eSelf-protecting output circuits\u003c\/li\u003e\n\u003cli\u003eHot-spare module support\u003c\/li\u003e\n\u003cli\u003eOnline module replacement capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency shutdown systems\u003c\/li\u003e\n\u003cli\u003eFire and gas protection systems\u003c\/li\u003e\n\u003cli\u003eBurner management systems\u003c\/li\u003e\n\u003cli\u003eBoiler flame safety systems\u003c\/li\u003e\n\u003cli\u003eGas and steam turbine protection\u003c\/li\u003e\n\u003cli\u003eCritical process interlocks\u003c\/li\u003e\n\u003cli\u003eSafety-related actuator control\u003c\/li\u003e\n\u003cli\u003eRefinery and petrochemical process protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eProduct Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3624\u003c\/td\u003e\n\u003ctd\u003e24 VDC TMR supervised digital output module with 16 commoned points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e3624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eTMR Supervised Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem\u003c\/th\u003e\n\u003ctd\u003eTricon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eArchitecture\u003c\/th\u003e\n\u003ctd\u003eTriple Modular Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Type\u003c\/th\u003e\n\u003ctd\u003eSupervised digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Isolation\u003c\/th\u003e\n\u003ctd\u003eOpto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Configuration\u003c\/th\u003e\n\u003ctd\u003eCommoned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Output Points\u003c\/th\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Field Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eField Voltage Range\u003c\/th\u003e\n\u003ctd\u003e16 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Field Voltage\u003c\/th\u003e\n\u003ctd\u003e36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Drop\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1.5 VDC, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Module Load\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Current per Point\u003c\/th\u003e\n\u003ctd\u003e0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Surge Current\u003c\/th\u003e\n\u003ctd\u003e4.8 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Required Load\u003c\/th\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Load Leakage\u003c\/th\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Protection\u003c\/th\u003e\n\u003ctd\u003eSelf-protecting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint Isolation\u003c\/th\u003e\n\u003ctd\u003e1,500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint Status Indicators\u003c\/th\u003e\n\u003ctd\u003eOne On or Off indicator per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Status Indicators\u003c\/th\u003e\n\u003ctd\u003ePASS, FAULT, ACTIVE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eField Alarm Indicators\u003c\/th\u003e\n\u003ctd\u003ePOWER and LOAD, one per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Color Code\u003c\/th\u003e\n\u003ctd\u003eTurquoise green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e0 degC to 60 degC, ambient at the bottom of the chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-40 degC to 75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSinusoidal Vibration\u003c\/th\u003e\n\u003ctd\u003e2 G at 10 to 150 Hz per axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock\u003c\/th\u003e\n\u003ctd\u003e15 G for 6 to 11 ms in each axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHot-Spare Support\u003c\/th\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eField Termination\u003c\/th\u003e\n\u003ctd\u003eSeparate external termination panel required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination Type\u003c\/th\u003e\n\u003cth\u003eCompatible Model\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommoned Termination Panel\u003c\/td\u003e\n\u003ctd\u003e9662-610F\u003c\/td\u003e\n\u003ctd\u003eCommoned field termination for 24 VDC digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Termination Panel\u003c\/td\u003e\n\u003ctd\u003e9653-610F\u003c\/td\u003e\n\u003ctd\u003eBasic field wiring termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonincendive Termination Panel\u003c\/td\u003e\n\u003ctd\u003e9671-610F\u003c\/td\u003e\n\u003ctd\u003eNonincendive field termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFanned-Out Cable\u003c\/td\u003e\n\u003ctd\u003e9101-010F\u003c\/td\u003e\n\u003ctd\u003eConnects the chassis backplane to separately marshalled field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Interface\u003c\/td\u003e\n\u003ctd\u003eTricon I\/O Bus\u003c\/td\u003e\n\u003ctd\u003eTransfers output and diagnostic data between the module and Main Processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible Tricon chassis I\/O slot.\u003c\/li\u003e\n\u003cli\u003eUse a supported external termination panel and interface cable.\u003c\/li\u003e\n\u003cli\u003eDo not connect field wiring directly to the module.\u003c\/li\u003e\n\u003cli\u003eMaintain the field supply between 16 and 30 VDC.\u003c\/li\u003e\n\u003cli\u003eEnsure each connected load draws at least 30 mA.\u003c\/li\u003e\n\u003cli\u003eKeep continuous point current within the 0.7 A rating.\u003c\/li\u003e\n\u003cli\u003eVerify that surge current does not exceed 4.8 A for 10 ms.\u003c\/li\u003e\n\u003cli\u003eInstall an identical module in the adjacent position when hot-spare operation is required.\u003c\/li\u003e\n\u003cli\u003eFollow the approved Tricon procedure for online module replacement.\u003c\/li\u003e\n\u003cli\u003eInstall the controller in an enclosure that prevents dust and falling debris entry.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate chassis airflow and the specified operating temperature.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53102421344619,"sku":"3624","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3624-burjbhyayb1.png?v=1776137106","url":"https:\/\/www.plcprotech.com\/hu\/products\/triconex-3624-tmr-supervised-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}