{"product_id":"abb-3bse013063r1-pu515-advant-ocs-real-time-accelerator-board","title":"ABB 3BSE013063R1 PU515 Advant OCS Real-Time Accelerator Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3BSE013063R1\u003c\/strong\u003e is a high-performance \u003cstrong\u003ePU515\u003c\/strong\u003e Real-Time Accelerator (RTA) board manufactured by ABB for the Advant OCS control system architecture. This communication module is designed to interface Master systems via a standard 5V, 32-bit, 33MHz PCI bus, delivering the dedicated real-time processing capability required for demanding industrial automation applications. The \u003cstrong\u003ePU515\u003c\/strong\u003e board features dual-channel MB300 communication protocols and comes equipped with 16 megabytes of onboard memory to ensure reliable, high-speed data throughput without lagging host system resources. Operating as a core communication module, the \u003cstrong\u003e3BSE013063R1\u003c\/strong\u003e ensures seamless link synchronization and real-time process monitoring within Advant Station 500 Series Engineering Stations and related MOD 300 control system environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt with 16 megabytes of onboard memory for intensive real-time data handling.\u003c\/li\u003e\n\u003cli\u003eImplements dual-channel MB300 communication for robust, deterministic network interfaces.\u003c\/li\u003e\n\u003cli\u003eEngineered for standard 5V, 32-bit, 33MHz PCI bus architecture in Master systems.\u003c\/li\u003e\n\u003cli\u003eForm-factor certified for Advant Station 500 Series Engineering Stations.\u003c\/li\u003e\n\u003cli\u003eMaximizes system uptime by processing critical communication protocols independently of the host CPU.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvant OCS with Master SW control network synchronization.\u003c\/li\u003e\n\u003cli\u003eAdvant Station 500 Series Engineering Stations requiring dedicated RTA communication.\u003c\/li\u003e\n\u003cli\u003eAdvant OCS with MOD 300 SW systems utilizing RTA communication units.\u003c\/li\u003e\n\u003cli\u003eReal-time industrial data acquisition and process supervision interface applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013063R1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePU515 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvant \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI bus (5V, 32-bit, 33MHz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16Mbyte \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual Channel MB300 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389091 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOld Product ID Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013063R0001 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Product ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE032401R1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e540 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.43 dm³ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003ePCI Slot Installation\u003c\/h3\u003e\n\u003cp\u003ePrior to handling the \u003cstrong\u003ePU515\u003c\/strong\u003e board, ensure that the host computer or engineering station is entirely powered down and disconnected from the main power source. Follow standard electrostatic discharge (ESD) protective measures by wearing a grounded wrist strap. Insert the board firmly into a compatible 5V 32-bit PCI slot along the motherboard until the edge connector is completely seated, then secure the mounting bracket screw.\u003c\/p\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eEnsure that the metal mounting bracket of the \u003cstrong\u003e3BSE013063R1\u003c\/strong\u003e board makes direct, unpainted contact with the industrial computer or workstation chassis frame. This path establishes a functional chassis ground essential for the onboard dual-channel MB300 transceiver shield circuits to suppress electromagnetic interference (EMI).\u003c\/p\u003e\n\u003ch3\u003eCable Routing\u003c\/h3\u003e\n\u003cp\u003eRoute all external communication cables connected to the dual-channel MB300 ports away from high-voltage primary AC power lines and motor drive paths to limit inductive noise pickup and guarantee signal transmission integrity.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668621357419,"sku":"PU515 3BSE013063R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-pu519-3bse018681r1-accelerator-rta-board-ilhnfapobu3_2bc273ab-4f12-4760-b607-a369447be9e2.jpg?v=1765535809","url":"https:\/\/www.plcprotech.com\/id\/products\/abb-3bse013063r1-pu515-advant-ocs-real-time-accelerator-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}