{"product_id":"abb-ci854bk01-3bse069449r1-ac-800m-profibus-dp-v1-interface-module","title":"ABB CI854BK01 3BSE069449R1 AC 800M PROFIBUS-DP\/V1 Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCI854BK01\u003c\/strong\u003e serves as a master communication interface designed to connect remote I\/O and fieldbus instruments to the AC 800M controller via the PROFIBUS DP protocol. This module enables high-speed data exchange with interconnected field devices—including remote I\/O, drives, low-voltage electrical equipment, and controllers. Operating as a PROFIBUS master, it features two distinct channels to implement line redundancy and actively supports PROFIBUS master redundancy. Master redundancy is realized by deploying two communication interface modules, which can be combined with CPU redundancy and CEXbus redundancy. The system interfaces directly with the S800 I\/O system as well as other PROFIBUS DP\/DP-V1 and FOUNDATION Fieldbus proficient systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnects remote I\/O and fieldbus instruments via PROFIBUS DP.\u003c\/li\u003e\n\u003cli\u003eIntegrates two PROFIBUS ports to support line redundancy.\u003c\/li\u003e\n\u003cli\u003eSupports PROFIBUS master redundancy via dual-module configuration.\u003c\/li\u003e\n\u003cli\u003eCompatible with CPU redundancy and CEXbus redundancy (BC810).\u003c\/li\u003e\n\u003cli\u003eEnables connection to PROFIBUS PA via the LD 800P linking device.\u003c\/li\u003e\n\u003cli\u003eSupports Hot Swap functionality for runtime replacement.\u003c\/li\u003e\n\u003cli\u003eValidated for operation with HI Controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed industrial fieldbus networking.\u003c\/li\u003e\n\u003cli\u003eRemote I\/O and drive control integration.\u003c\/li\u003e\n\u003cli\u003eRedundant DCS\/PLC communication architectures.\u003c\/li\u003e\n\u003cli\u003eProcess automation environments requiring FOUNDATION Fieldbus or PROFIBUS DP-V1 capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eArticle Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eIncluded Components\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BSE069449R1\u003c\/td\u003e\n\u003ctd\u003eCI854BK01 Communication Interface Kit\u003c\/td\u003e\n\u003ctd\u003eCI854BK01 Communication Interface, TP854 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE069449R1 (CI854BK01)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP-V1  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRole\u003c\/td\u003e\n\u003ctd\u003eMaster  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e9.6 to 12 000 kbit\/s  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Units on CEX Bus\u003c\/td\u003e\n\u003ctd\u003e12  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eDB female (9-pin)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V Consumption Typ.\u003c\/td\u003e\n\u003ctd\u003e190 mA  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed Together with HI Controller\u003c\/td\u003e\n\u003ctd\u003eYes  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC (+32 to +131 degF)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2 according to IEC\/EN61131-2  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 compliant to ISA 71.04  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN60529, IEC 529  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm (2.3 in.)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm (7.3 in.)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm (5.0 in.)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (including base)\u003c\/td\u003e\n\u003ctd\u003e700 g (1.5 lbs)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module and baseplate assembly onto a standard DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Ensure system configuration utilizes System 800xA 6.0.3.2, Compact Control Builder 6.0.0-2, or onwards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e The PROFIBUS DP network must be strictly terminated at the two outermost nodes. Use connectors equipped with built-in termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Power:\u003c\/strong\u003e To guarantee functional bus termination, the connector must remain securely plugged in and supplied with electrical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE-marking: Yes \u003c\/li\u003e\n\u003cli\u003eMarine Certificates: ABS, BV, DNVGL-, LR \u003c\/li\u003e\n\u003cli\u003eRoHS Compliance: EU ROHS, UAE ROHS, CN ROHS \u003c\/li\u003e\n\u003cli\u003eWEEE Compliance: DIRECTIVE\/201219\/\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668626043243,"sku":"CI854BK01 3BSE069449R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-ci854bk01-3bse069449r1-profibus-dp-v1-interface-model-f44uabkttdo_f53097be-0eac-4b71-90c0-a7ed8311db92.jpg?v=1765535985","url":"https:\/\/www.plcprotech.com\/id\/products\/abb-ci854bk01-3bse069449r1-ac-800m-profibus-dp-v1-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}