{"product_id":"abb-ci867k01-3bse043660r1-system-800xa-modbus-tcp-interface","title":"ABB CI867K01 3BSE043660R1 System 800xA Modbus TCP Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFacilitating seamless Ethernet-based industrial communications, the \u003cstrong\u003eABB CI867K01 3BSE043660R1\u003c\/strong\u003e acts as a high-performance Modbus TCP interface kit within the System 800xA and AC 800M controller architecture. This communication package includes the \u003cstrong\u003eCI867 communication module\u003c\/strong\u003e and the \u003cstrong\u003eTP867 baseplate\u003c\/strong\u003e, enabling direct connectivity to field instruments, third-party PLCs, and SCADA control networks. Engineered for high-speed industrial telemetry, it functions natively as both a Modbus TCP Master and Slave, ensuring flexible and reliable data exchanges across modern automated systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDual-channel RJ45 Ethernet interfaces supporting 10\/100 Mbps transmission speeds.\u003c\/li\u003e\n  \u003cli\u003eIncludes the rugged TP867 baseplate for stable backplane mounting and reliable shielding.\u003c\/li\u003e\n  \u003cli\u003eComprehensive protocol handling for Modbus TCP Master and Slave configurations.\u003c\/li\u003e\n  \u003cli\u003eFull integration with ABB Control Builder M configuration software.\u003c\/li\u003e\n  \u003cli\u003eHot-swappable communication hardware for maximum system availability and reduced downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIntegration of intelligent electronic devices (IEDs) and power meters into central control networks.\u003c\/li\u003e\n  \u003cli\u003eInter-controller communications between ABB AC 800M assemblies and third-party PLC architectures.\u003c\/li\u003e\n  \u003cli\u003eDistributed SCADA telemetry in water treatment, chemical processing, and power generation plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; min-width: 600px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCI867K01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eProduct ID \/ SKU\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3BSE043660R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eModbus TCP Communication Interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003ePhysical Composition\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCI867 Module \u0026amp; TP867 Baseplate Assembly\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eEthernet Ports\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2x RJ45 (Ch1, Ch2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100 Mbps (Auto-negotiation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eConnection Limit\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUp to 120 simultaneous TCP connections\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eCustoms Tariff Number\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSweden\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.7 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.95 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eDimensions (D x H x W)\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e127.5 x 186 x 59 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; min-width: 600px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eInterface Terminal\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCh1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePrimary Ethernet Connection (Modbus TCP Network)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCh2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSecondary Ethernet Connection \/ Network Redundancy Path\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eBackplane Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTP867 Baseplate Interconnect\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC Power Input and Internal System Bus Communication\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CI867K01 package directly succeeds older Modbus solutions within System 800xA. It requires \u003cstrong\u003eControl IT firmware version 5.1\u003c\/strong\u003e or higher loaded onto the PM8xx controller for correct interface addressing. If you are retrofitting older systems using Control Software version 5.0 or earlier, firmware upgrades or compatibility configuration patches are mandatory to ensure that the AC 800M controller recognizes the dual-channel capability of the TP867 baseplate assembly.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent communication module lockups, avoid overloading the 120-connection threshold. When configuring master devices, group individual Modbus polling requests into unified, block-read transactions instead of continuous, discrete register queries. This minimizes packet rates and protects the module's microprocessor from thermal overhead inside enclosed unventilated panels.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eAlways use Shielded Twisted Pair (STP) Cat5e or Cat6 cabling to prevent Electromagnetic Interference (EMI) in high-voltage switchgear environments. Ground the cable shields strictly at the industrial patch panel end rather than the TP867 baseplate to suppress potential ground loops. Confirm that the default network routing tables in Control Builder match the physical local network gateway to bypass ARP resolution failure.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eDe-energize all AC 800M backplane power lines and external communication devices prior to installing or removing the TP867 baseplate. Static discharge and raw voltage spikes can cause irreversible hardware damage to the communication bus components.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the TP867 baseplate onto the grounded standard horizontal DIN rail until the plastic locking tab clicks firmly into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the slide connectors of the adjacent communication or CPU modules to bridge the backplane connection path.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eCarefully insert the CI867 interface module into the slot of the TP867 baseplate, exerting even pressure until it sits flush.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; font-weight: bold; margin-right: 15px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the shielded RJ45 cables to Port Ch1 and\/or Ch2, route the cabling through the designated panel ducting, and power on the system for commissioning.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958373739,"sku":"3BSE043660R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse043660r1-lfm2k15nibk_12fe9fef-318b-4a42-9e3e-4954c8e5af5b.jpg?v=1766478151","url":"https:\/\/www.plcprotech.com\/id\/products\/abb-ci867k01-3bse043660r1-system-800xa-modbus-tcp-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}