{"product_id":"allen-bradley-1768-enbt-compactlogix-ethernet-ip-communication-module","title":"Modul Komunikasi Allen-Bradley 1768-ENBT CompactLogix EtherNet\/IP  ","description":"\u003cp\u003eThe \u003cstrong\u003e1768-ENBT\u003c\/strong\u003e is a \u003cstrong\u003eCompactLogix EtherNet\/IP Communication Module\u003c\/strong\u003e developed by \u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e to provide dedicated Ethernet networking capabilities for 1768 control systems. This module establishes reliable data transmission links across an industrial network, enabling seamless connectivity with multiple Logix5000 controllers, supervisory computers, and auxiliary automation equipment. It processes network traffic over a integrated communication interface while managing local status via an alphanumeric display and built-in diagnostic indicators. Designed as an open-type component, it installs directly within a synchronized hardware stack consisting of a 1768 controller and compatible power supplies to optimize throughput and minimize communication downtime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides automated data management over EtherNet\/IP networks to reduce packet collisions and sustain optimal bandwidth.\u003c\/li\u003e\n\u003cli\u003eFeatures an integrated alphanumeric display and three bi-color diagnostic status indicators (NET, Link, and OK) for rapid local troubleshooting.\u003c\/li\u003e\n\u003cli\u003eSupports high-speed data transmission over standard Category 5 or Category 5e cabling using a rugged RJ45 connector interface.\u003c\/li\u003e\n\u003cli\u003eImplements reliable electrical protection with a continuous functional insulation rating of 30V between the Ethernet network and internal system circuits.\u003c\/li\u003e\n\u003cli\u003eInterfaces directly with specialized 1768 CompactLogix system components and supports flexible expansion using combined 1769-series I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed industrial automation and manufacturing plant network management.\u003c\/li\u003e\n\u003cli\u003eInter-controller data synchronization across multiple Logix5000 systems.\u003c\/li\u003e\n\u003cli\u003eSCADA network routing and remote control system interface integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e834 mA at 5.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.34 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.38 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e30V (continuous-voltage rating), Functional Insulation Type, Ethernet network to system (Type tested at 710V DC for 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003eRJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO\/IEC 24702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Category\u003c\/td\u003e\n\u003ctd\u003e2 - on communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Temp Code\u003c\/td\u003e\n\u003ctd\u003eT4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC Temp Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Screw Torque\u003c\/td\u003e\n\u003ctd\u003e1.16 N.m (10 lb.in) using M4 or #8 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD), Approx.\u003c\/td\u003e\n\u003ctd\u003e132 x 56.7 x 105.1 mm (5.20 x 2.23 x 4.12 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, Approx.\u003c\/td\u003e\n\u003ctd\u003e0.213 kg (7.5 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature, Operating\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature, Nonoperating\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 g @ 10...500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Shock\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions\u003c\/td\u003e\n\u003ctd\u003eCISPR 11 Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 1\u003c\/td\u003e\n\u003ctd\u003eTD+ (Transmit Data +)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 2\u003c\/td\u003e\n\u003ctd\u003eTD- (Transmit Data -)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 3\u003c\/td\u003e\n\u003ctd\u003eRD+ (Receive Data +)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 4\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 5\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 6\u003c\/td\u003e\n\u003ctd\u003eRD- (Receive Data -)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 7\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin 8\u003c\/td\u003e\n\u003ctd\u003eNC (No Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlan for a minimum hardware clearance of 105 mm (4 in.) at the top and bottom, and 90 mm (3.54 in.) on the sides from enclosure walls, wireways, and adjacent machinery.\u003c\/li\u003e\n\u003cli\u003eEnsure the system is grounded through the DIN rail to the chassis ground by utilizing zinc-plated yellow-chromate steel DIN rail; avoid aluminum or plastic rails which can oxidize and cause poor conductivity.\u003c\/li\u003e\n\u003cli\u003eSecure the mounting DIN rail to the surface approximately every 200 mm (7.87 in.) and install appropriate end-anchors to hold modules firmly.\u003c\/li\u003e\n\u003cli\u003eIf choosing panel mounting instead of DIN rail installation, mark pilot holes using the hardware as a template, drill holes for M4 or #8 screws, and tighten to 1.16 N.m (10 lb.in) of torque. Do not use screws and DIN rail concurrently.\u003c\/li\u003e\n\u003cli\u003eConnect the network interface cable to a 100 MB Ethernet switch rather than a shared hub to increase network bandwidth and reduce lost packets.\u003c\/li\u003e\n\u003cli\u003eNever connect or disconnect network communication cables while power is actively applied, as an electrical arc can occur and present an explosion hazard in certified environments.\u003c\/li\u003e\n\u003cli\u003eAlways wait for all diagnostic status lights on the power supply and controller to turn completely off before disconnecting any system module to allow the processor sufficient time to finish writing project parameters to non-volatile memory.\u003c\/li\u003e\n\u003cli\u003eMitigate static risks by touching a grounded object, wearing an approved grounding wriststrap, and strictly avoiding contact with component board pins, connectors, or internal circuit elements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ec-UL-us Listed Industrial Control Equipment, Certified for US and Canada (UL File E65584)\u003c\/li\u003e\n\u003cli\u003ec-UL-us Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, Certified for US and Canada (UL File E194810)\u003c\/li\u003e\n\u003cli\u003eCE Certified (European Union 2004\/108\/EC EMC Directive, compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, and EN 61131-2)\u003c\/li\u003e\n\u003cli\u003eC-Tick Compliant (Australian Radiocommunications Act, compliant with AS\/NZS CISPR 11)\u003c\/li\u003e\n\u003cli\u003eEx Certified (European Union 94\/9\/EC ATEX Directive, compliant with EN 60079-15 and EN 60079-0; II 3 G Ex nA IIC T4)\u003c\/li\u003e\n\u003cli\u003eEtherNet\/IP ODVA Conformance Tested\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181295979,"sku":"1768-ENBT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1768-enbt-ethernet-communication-module-xn03bzvskda_9fdc6228-c7e0-4e2d-99ef-e63c97bad7a7.jpg?v=1766114297","url":"https:\/\/www.plcprotech.com\/id\/products\/allen-bradley-1768-enbt-compactlogix-ethernet-ip-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}