{"product_id":"beckhoff-el3062-0030-ethercat-terminal-2-channel-analog-input-terminal","title":"BECKHOFF EL3062-0030 EtherCAT Terminal 2-channel Analog Input Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eProcessing standard single-ended analog signals in industrial automation systems is efficiently handled by the \u003cstrong\u003eEL3062-0030\u003c\/strong\u003e. This robust \u003cstrong\u003eanalog input terminal\u003c\/strong\u003e operates within the 0 V to +10 V voltage range, digitizing incoming signals with a high-performance 12-bit resolution for transmission to the master control system. Engineered for seamless integration with the Beckhoff EtherCAT Terminal system, it combines high-speed communication via the internal E-bus with galvanic safety features. Compact and highly reliable, it is ideal for standard control applications requiring fast, noise-immune signal acquisition.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual single-ended analog inputs configured for 0 V to +10 V signal ranges.\u003c\/li\u003e\n  \u003cli\u003eDigitization resolution of 12 bits with a 16-bit representation format.\u003c\/li\u003e\n  \u003cli\u003eTypical conversion time of 0.625 ms using the default 50 Hz internal filter.\u003c\/li\u003e\n  \u003cli\u003eGalvanic electrical isolation rated at 500 V between the E-bus and the field circuit.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 1 kHz input limit filter for high-frequency noise suppression.\u003c\/li\u003e\n  \u003cli\u003eExcellent electromagnetic compatibility complying with industrial emission and immunity standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis 2-channel analog input terminal is widely implemented across heavy industrial and manufacturing environments, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine control and process automation.\u003c\/li\u003e\n  \u003cli\u003eContinuous monitoring of industrial sensors and transmitters.\u003c\/li\u003e\n  \u003cli\u003eFactory automation lines requiring reliable 0-10 V analog data acquisition.\u003c\/li\u003e\n  \u003cli\u003eTest bench and laboratory instrumentation setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEL3062-0030\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2-channel Analog Input Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 V to +10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 130 kOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 bit (16 bit presentation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypical 0.625 ms (default 50 Hz filter setting)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Limit Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Error (Full Range)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; ± 0.30% (at 0 degC to +55 degC, relative to full scale); \u0026lt; ± 0.5% (extended temperature range)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption via E-Bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypical 130 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ field voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 30 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePermissible Relative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 10 cm x 1.5 cm x 7 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor safe and optimal performance of the terminal block, adhere to the following installation standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Snap the terminal securely onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism engages properly with adjacent terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e To minimize high-frequency electromagnetic interference, use shielded signal cables and connect the shield directly to the mounting rail or grounding terminal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Ensure the installation enclosure provides an IP54 or higher rating if operating in harsh, dust-heavy, or wet industrial environments, as the module itself is rated IP20.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain standard vertical clearance above and below the terminal assembly to prevent thermal buildup and ensure reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eEN 61000-6-2 (Electromagnetic compatibility - Immunity for industrial environments)\u003c\/li\u003e\n  \u003cli\u003eEN 61000-6-4 (Electromagnetic compatibility - Emission standard for industrial environments)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106540544363,"sku":"EL3062-0030","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/EL3062-0030-urnole5fsxp.png?v=1776244433","url":"https:\/\/www.plcprotech.com\/id\/products\/beckhoff-el3062-0030-ethercat-terminal-2-channel-analog-input-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}