{"product_id":"beckhoff-el7211-0010-ethercat-terminal","title":"Beckhoff EL7211-0010 EtherCAT Terminal","description":"\u003ch1\u003eBeckhoff EL7211-0010 EtherCAT Terminal\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for space-restricted motion control applications, the \u003cstrong\u003eBeckhoff EL7211-0010\u003c\/strong\u003e is a compact, high-performance \u003cstrong\u003eservomotor EtherCAT Terminal\u003c\/strong\u003e featuring integrated One Cable Technology (OCT). This single-channel motion interface enables direct connection of permanent magnet-excited three-phase synchronous motors up to 4.5 A (RMS) at 48 V DC. By combining power and feedback lines into a single cable, the module significantly reduces wiring complexity, installation space, and overall system costs. The terminal integrates high-speed current, speed, and position control loops, delivering dynamic positioning capabilities directly within the modular EtherCAT I\/O system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-channel compact drive technology for permanent magnet-excited three-phase synchronous motors.\u003c\/li\u003e\n  \u003cli\u003eSupports One Cable Technology (OCT) for simplified motor connection and absolute feedback.\u003c\/li\u003e\n  \u003cli\u003eDelivers a continuous output current of 4.5 A RMS, with a peak current capacity of up to 9.0 A for 1 second.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 24 V DC motor brake control output rated up to 0.5 A.\u003c\/li\u003e\n  \u003cli\u003eEquipped with 2 end position inputs and 1 feedback interface.\u003c\/li\u003e\n  \u003cli\u003eSupports Distributed Clocks (DC) for precise, microsecond-level synchronization across the EtherCAT network.\u003c\/li\u003e\n  \u003cli\u003eHigh-density (HD) housing design with integrated signal LEDs for real-time status diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging and labeling machinery.\u003c\/li\u003e\n  \u003cli\u003ePick-and-place assembly systems.\u003c\/li\u003e\n  \u003cli\u003eAutomated material handling and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eRobotic joint positioning and small-scale gantry systems.\u003c\/li\u003e\n  \u003cli\u003eSemiconductor manufacturing equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEL7211-0010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal (1-channel motion interface)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePermanent magnet-excited three-phase synchronous motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x end position, 1 x feedback\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x servomotor, 1 x motor brake\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage (Electronics)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (via power contacts)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Voltage (Power)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 to 48 V DC (external)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Current (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePeak Output Current (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.0 A (maximum for 1 second)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRotating Field Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 599 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePWM Clock Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Controller Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Speed Controller Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMotor Brake Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMotor Brake Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaximum 0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Power Contacts)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypically 50 mA + holding current of motor brake\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (E-bus)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypically 120 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDistributed Clocks\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 95 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Parameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWiring Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation via screwdriver (solid, flexible, or ferrule)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSolid Wire Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm² (AWG 28 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStranded Wire Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 to 1.5 mm² (AWG 22 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFerrule Wire Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 0.75 mm² (AWG 26 to 19)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Contacts Current Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMaximum 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount horizontally on a standard 35 mm DIN rail conforming to EN 60715. Secure using the integrated locking mechanism.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSide-by-Side Installation:\u003c\/strong\u003e Align terminals side-by-side using the double slot and key connection system to ensure reliable E-bus communication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Ensure the DIN rail is properly grounded to a low-impedance reference point. Use shielded motor cables to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain adequate clearance above and below the terminal block to allow natural convection cooling, keeping the operating temperature below +55 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European EMC and Low Voltage Directives.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL listed for industrial control equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Immunity\/Emission:\u003c\/strong\u003e Conforms to EN 61000-6-2 and EN 61000-6-4.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration\/Shock Resistance:\u003c\/strong\u003e Conforms to EN 60068-2-6 and EN 60068-2-27.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106532319595,"sku":"EL7211-0010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el7211-0010-1gz1f1q04pb.png?v=1776244575","url":"https:\/\/www.plcprotech.com\/id\/products\/beckhoff-el7211-0010-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}