{"product_id":"beckhoff-elx3152-0090-ethercat-terminal","title":"BECKHOFF ELX3152-0090 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDirecting high-precision analog measurements in hazardous environments, the \u003cstrong\u003eELX3152-0090\u003c\/strong\u003e is an \u003cstrong\u003eintrinsically safe analog input terminal\u003c\/strong\u003e designed for the direct integration of field devices from Zone 0\/20 explosion-hazard areas. This 2-channel single-ended interface processes standard 0\/4 to 20 mA current signals with 16-bit resolution. Integrated with \u003cstrong\u003eTwinSAFE SC\u003c\/strong\u003e (Single Channel) technology, the terminal enables safety-supporting signals to be analyzed and utilized within standard industrial control systems, expanding diagnostic depth and process safety across complex control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect connection of intrinsically safe field devices from Zone 0\/20 and Zone 1\/21.\u003c\/li\u003e\n  \u003cli\u003eTwo independent single-ended analog input channels supporting 0 to 20 mA and 4 to 20 mA signals.\u003c\/li\u003e\n  \u003cli\u003eTwinSAFE SC capability for integrating safety-assisting monitoring functions.\u003c\/li\u003e\n  \u003cli\u003eHigh-resolution 16-bit representation for highly accurate field instrument monitoring.\u003c\/li\u003e\n  \u003cli\u003eSupports Distributed Clocks (DC) for highly synchronized and precise EtherCAT process data acquisition.\u003c\/li\u003e\n  \u003cli\u003eAdvanced internal processing options including activatable digital FIR\/IIR filters.\u003c\/li\u003e\n  \u003cli\u003eDiagnostic compliance with NE43 NAMUR sensor limit specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas extraction, processing, and refining facilities.\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical process plants requiring intrinsic safety (Ex i).\u003c\/li\u003e\n  \u003cli\u003eIndustrial wastewater treatment facilities with explosive gas atmospheres.\u003c\/li\u003e\n  \u003cli\u003ePharmaceutical processing lines managing volatile substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eELX3152-0090\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Terminal (Ex i, TwinSAFE SC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Current Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0\/4...20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2- or 3-wire (default: 3-wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 bit (including sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; +\/-0.3% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Measuring Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 100 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Limit Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectronics Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (via power contacts, powered by ELX9560)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Power Contacts)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 10 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (E-bus)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 85 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDistributed Clocks (DC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Property\u003c\/th\u003e\n      \u003cth\u003eSpecification \/ Wire Size\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSolid wire, stranded wire, or wire with ferrule (spring-actuated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSolid Conductor (s)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28...14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStranded Conductor (st)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm² (AWG 28...14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFlexible Conductor with Ferrule (f)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm² (AWG 26...16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Contacts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 blade\/spring contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount securely on a standard 35 mm DIN rail conforming to EN 60715 using the locking mechanism.\u003c\/li\u003e\n  \u003cli\u003eEnsure adjacent terminal modules are locked using the integrated double-slot and key housing connections.\u003c\/li\u003e\n  \u003cli\u003ePower the terminal exclusively through a certified ELX9560 power supply module to satisfy all intrinsically safe electrical isolation standards.\u003c\/li\u003e\n  \u003cli\u003eEnsure appropriate spacing and ventilation within the terminal cluster as defined by the hazardous zone class regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE, UL\u003c\/li\u003e\n  \u003cli\u003eATEX: II 3(1)G Ex ec [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I\u003c\/li\u003e\n  \u003cli\u003eIECEx: Ex ec [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/li\u003e\n  \u003cli\u003ecFMus: AIS Class I, II, III, Division 1, Groups A-G; Class I, Division 2, Groups A-D; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106431066475,"sku":"ELX3152-0090","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/elx3152-0090-xjn5t00ywkm.png?v=1776244613","url":"https:\/\/www.plcprotech.com\/id\/products\/beckhoff-elx3152-0090-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}