{"product_id":"beckhoff-epp2809-0022-ethercat-p-box-16-channel-digital-output-module","title":"BECKHOFF EPP2809-0022 EtherCAT P Box 16-Channel Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBeckhoff EPP2809-0022\u003c\/strong\u003e is a rugged, decentralized \u003cstrong\u003eEtherCAT P Box\u003c\/strong\u003e designed for processing digital output signals in demanding industrial environments. Equipped with \u003cstrong\u003e16 digital outputs\u003c\/strong\u003e, this module connects actuators such as solenoid valves, contactors, indicators, and small motor starters directly to the fieldbus. By utilizing the advanced \u003cstrong\u003eEtherCAT P technology\u003c\/strong\u003e, the unit integrates high-speed fieldbus communication and dual-channel power distribution ($U_S$ for system\/sensor supply and $U_P$ for peripheral load voltage) into a single, shielded M8 cable. This consolidated cabling method significantly reduces wiring complexity, accelerates installation time, and eliminates the need for separate power distribution junction boxes.\u003c\/p\u003e\n\n\u003cp\u003eEncased in a compact, highly protective housing, the \u003cstrong\u003eEPP2809-0022\u003c\/strong\u003e features standard M12 connection sockets to interface with external actuators. Each of the 16 output channels is designed to drive ohmic, inductive, and lamp loads with a nominal output current of 0.5 A. Built-in electronic protection ensures individual channel stability during fault conditions, making this fieldbus module an excellent selection for distributed control architectures in dust- and moisture-prone industrial settings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 16 digital output channels in a highly durable, compact space-saving design.\u003c\/li\u003e\n  \u003cli\u003eUtilizes EtherCAT P single-cable technology for integrated power and fast, deterministic Ethernet communication.\u003c\/li\u003e\n  \u003cli\u003eEach digital output channel is individually short-circuit proof, protecting the control network from isolated electrical faults.\u003c\/li\u003e\n  \u003cli\u003eSupports ohmic, inductive, and lamp load profiles with a nominal switching current of 0.5 A per channel.\u003c\/li\u003e\n  \u003cli\u003eRobust IP65, IP66, and IP67 protection ratings, allowing cabinet-free mounting directly on machines.\u003c\/li\u003e\n  \u003cli\u003eStandard A-coded M12 output sockets ensure reliable connector mating with heavy-duty actuator cabling.\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic LEDs for quick visual monitoring of channel states, communication activity, and power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly lines, robotic welding systems, and end-of-arm tooling systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems, sortation lines, and packaging machinery.\u003c\/li\u003e\n  \u003cli\u003eMachine tool engineering, CNC workstations, and custom metalworking machinery.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater processing equipment situated in cabinet-free environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEPP2809-0022\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type, P-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 x 1, 5-pin, A-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (individually short-circuit proof), sum maximum 3 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitching Times\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. TON: 60 us, typ. TOFF: 300 us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003emax. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption from Us\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAuxiliary Power Current (Up)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 20 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 250 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector \/ Port Specification\u003c\/th\u003e\n      \u003cth\u003eCoding\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEtherCAT P Network Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type\u003c\/td\u003e\n      \u003ctd\u003eP-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 x 1 socket, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eA-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module securely to a clean, flat mounting profile or machine frame using the integrated mounting holes.\u003c\/li\u003e\n  \u003cli\u003eTo guarantee the IP65\/66\/67 rating, all unused M8 and M12 sockets must be fitted with certified plastic or metal protective caps.\u003c\/li\u003e\n  \u003cli\u003eAlways use pre-assembled, shielded EtherCAT P cabling with P-coded M8 connectors to prevent communication loss and ensure reliable shielding grounding.\u003c\/li\u003e\n  \u003cli\u003eObserve the maximum allowable sum current limit of 3 A across all output channels to prevent thermal overloading of the internal power bus.\u003c\/li\u003e\n  \u003cli\u003eRoute field cabling away from high-voltage motor cables and frequency inverter drives to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106529468779,"sku":"EPP2809-0022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/epp2809-0022-tmwzrzb1d42.png?v=1776244745","url":"https:\/\/www.plcprotech.com\/id\/products\/beckhoff-epp2809-0022-ethercat-p-box-16-channel-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}