{"product_id":"beckhoff-epp6001-0002-ethercat-p-box-serial-interface-module","title":"Beckhoff EPP6001-0002 EtherCAT P Box Serial Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for direct connection of serial devices in harsh industrial environments, the \u003cstrong\u003eBeckhoff EPP6001-0002\u003c\/strong\u003e serial interface module provides high-performance data transmission via the EtherCAT P network protocol. This compact, machine-mountable I\/O box enables the integration of devices featuring RS232, RS485, or RS422 interfaces directly into the control network, bypassing the need for protective control cabinets.\u003c\/p\u003e\n\n\u003cp\u003eThe module transmits serial data in a fully bidirectional format to the controller, utilizing an active internal buffer to manage high-speed communication independent of the EtherCAT cycle time. It features integrated digital inputs and outputs, alongside an auxiliary 5 V DC power supply to directly drive connected sensors or terminal equipment, minimizing external wiring requirements.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelectable Communication Interfaces:\u003c\/strong\u003e Configure each channel individually for RS232, RS485, or RS422 standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Device Supply:\u003c\/strong\u003e Delivers a local auxiliary +5 V DC, 1 A supply specifically for end devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Digital I\/O:\u003c\/strong\u003e Outfitted with two digital 24 V DC inputs and two short-circuit proof digital 24 V DC outputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust EtherCAT P Integration:\u003c\/strong\u003e Utilizes shielded, P-coded M8 connections for combined power and data transmission.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardened IP67 Enclosure:\u003c\/strong\u003e Encased in a durable polyamide housing with excellent resistance to vibration, shock, and moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and Gas processing facilities\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution systems\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment infrastructure\u003c\/li\u003e\n  \u003cli\u003eRobotic assembly and specialized material handling lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEPP6001-0002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT P\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw-type, P-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 serial channel, 2 digital inputs, 2 digital outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRS232, RS485, RS422 (individually selectable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e300 to 115,200 baud (9600 baud preset)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBit Distortion\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 3 percent\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRS232: max. 15 m; RS422\/RS485: approx. 1000 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Buffer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e864 bytes receive buffer, 128 bytes transmit buffer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+5 V DC, 1 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 inputs, 24 V DC, type 3 (EN 61131-2), 10 us input filter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 outputs, 24 V DC, 0.5 A per channel, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (US)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypically 100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 126 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 165 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Attach to a flat machine surface using the two integrated 3.5 mm diameter fixing holes designed for M3 screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e Ensure all M8 and M12 connectors are tightened to their designated torque specification to maintain the IP67 ingress protection rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Grounding and shielding connection must be established correctly via the EtherCAT P bus interface connectors to limit electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain unobstructed air space around the unit when operating near the upper ambient temperature limit of +60 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eEMC Immunity\/Emission: EN 61000-6-2 \/ EN 61000-6-4\u003c\/li\u003e\n  \u003cli\u003eVibration\/Shock Resistance: EN 60068-2-6 \/ EN 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106456461675,"sku":"EPP6001-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/epp6001-0002-4xiox1mi3fq.png?v=1776244758","url":"https:\/\/www.plcprotech.com\/id\/products\/beckhoff-epp6001-0002-ethercat-p-box-serial-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}