{"product_id":"beckhoff-ip2310-b730-fieldbus-box-digital-i-o-module","title":"BECKHOFF IP2310-B730 Fieldbus Box Digital I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for decentralized automation tasks, the \u003cstrong\u003eBeckhoff IP2310-B730\u003c\/strong\u003e is a rugged, IP67-rated \u003cstrong\u003efieldbus box module\u003c\/strong\u003e featuring 4 digital inputs and 4 digital outputs. This module establishes reliable communication using serial RTU\/ASCII protocols over an RS485 physical interface, enabling robust data exchange directly on the machinery. The integrated 8 mm snap-type connectors facilitate rapid peripheral connections, making it optimal for direct machine mounting without protective enclosures.\u003c\/p\u003e\n\n\u003cp\u003eBy shifting the I\/O level directly into the field, the \u003cstrong\u003eIP2310-B730\u003c\/strong\u003e significantly reduces wiring overhead and control cabinet space requirements. Built-in short-circuit protection for both sensor supply and outputs ensures operational reliability in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect connection to RS485 serial fieldbus networks using RTU\/ASCII protocols.\u003c\/li\u003e\n  \u003cli\u003eSupports multiple data transfer rates from 150 baud up to 38,400 baud.\u003c\/li\u003e\n  \u003cli\u003eFour digital inputs with a fast 0.2 ms input filter.\u003c\/li\u003e\n  \u003cli\u003eFour short-circuit protected digital outputs rated at 0.5 A per channel.\u003c\/li\u003e\n  \u003cli\u003eRobust PA6 polyamide housing with IP65, IP66, and IP67 ingress protection.\u003c\/li\u003e\n  \u003cli\u003eAddress configuration via integrated rotary selection switches or KS2000 software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machinery control and assembly systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eProcess automation in harsh industrial environments.\u003c\/li\u003e\n  \u003cli\u003eRemote I\/O monitoring in manufacturing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP2310-B730\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Digital Input\/Output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRTU \/ ASCII\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScreened, twisted copper cable 2 x 0.25 mm² (RS485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150, 300, 600, 1200, 2400, 4800, 9600, 19,200, 38,400 baud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\n    \u003ctd\u003e4 inputs + 4 outputs\u003c\/td\u003e\n    \n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\"0\" signal: -3 to +5 V; \"1\" signal: 11 to 30 V (6 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Feed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Downstream\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Control Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 210 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/li\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eInterface Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male connector, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Loop-through\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female connector, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Sockets\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 x 8 mm snap-type connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount vertically or horizontally on flat machine surfaces using two 3.5 mm diameter fixing holes for M3 screws.\u003c\/li\u003e\n  \u003cli\u003eTo achieve IP67 protection, ensure all unused I\/O and communication interfaces are sealed with watertight protective caps.\u003c\/li\u003e\n  \u003cli\u003eUse only screened, twisted-pair copper cabling (2 x 0.25 mm²) for the RS485 communication line to avoid electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eObserve polarity and voltage tolerances on the 24 V DC control voltage input to prevent logic-side damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106459672939,"sku":"IP2310-B730","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2310-b730-e4knsnj0xqf.png?v=1776245013","url":"https:\/\/www.plcprotech.com\/id\/products\/beckhoff-ip2310-b730-fieldbus-box-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}