{"product_id":"beckhoff-ks6011-ks-series-bus-terminal","title":"Beckhoff KS6011 KS Series Bus Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eSerial data transmission via 20 mA current loop interfaces is facilitated by the \u003cstrong\u003eBeckhoff KS6011\u003c\/strong\u003e Bus Terminal. This module enables the direct integration of active or passive TTY-interface devices into the Beckhoff K-bus system, bypassing the need for external converters. Operating as a full duplex interface on two channels (TxD and RxD), the device handles communication tasks independently of the higher-level bus system, utilizing internal data buffers to ensure reliable data transfer even during intensive process cycles.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features a pluggable wiring design typical of the KS series, which simplifies installation, commissioning, and maintenance. Wiring connection blocks can be detached as a single unit without disconnecting individual conductors, reducing downtime during module replacement. Complete galvanic isolation provides high-noise immunity, making it suitable for long-distance point-to-point connections in challenging industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eActive\/passive 2 x 20 mA current loop (TTY) interface technology.\u003c\/li\u003e\n  \u003cli\u003eFull duplex data transfer across dedicated transmit (TxD) and receive (RxD) channels.\u003c\/li\u003e\n  \u003cli\u003eConfigurable transfer rates ranging from 1200 to 19,200 baud (default: 9600 baud).\u003c\/li\u003e\n  \u003cli\u003eIntegrated data buffers including a 128-byte receive buffer and a 16-byte transmit buffer.\u003c\/li\u003e\n  \u003cli\u003ePluggable wiring level for rapid tool-free maintenance.\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation of 500 V between the K-bus backplane and signal lines.\u003c\/li\u003e\n  \u003cli\u003eFlexible process image configuration via standard Bus Couplers or controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnection of legacy terminal systems, printers, and laboratory instruments with TTY ports.\u003c\/li\u003e\n  \u003cli\u003eLong-range point-to-point serial communication (up to 1000 m) in high-noise manufacturing plants.\u003c\/li\u003e\n  \u003cli\u003eIndustrial weighing systems and barcode reader integration.\u003c\/li\u003e\n  \u003cli\u003eHazardous area automation applications requiring Ex nA certified components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKS6011\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterface Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTTY (2 x 20 mA active\/passive current loop)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 (1 TxD, 1 RxD, full duplex)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1200 to 19,200 baud (Default: 9600 baud, 8 data bits, no parity, 1 stop bit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 500 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1000 m (twisted pair)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVia K-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption K-Bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 55 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Buffer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e128 bytes receive buffer, 16 bytes transmit buffer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBit Width in Process Image\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInput\/output: 3 x 8-bit user data, 1 x 8-bit control\/status (up to 5 x 8-bit user data configurable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (EN 60715) with locking mechanism\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSolid\/stranded: 0.08 to 1.5 mm², Flexible: 0.14 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Cross-Section AWG\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSolid\/stranded: AWG 28 to 16, Flexible: AWG 26 to 16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9 to 10 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the unit on standard 35 mm DIN rails complying with EN 60715. Ensure the interlocking double slot and key system is secure.\u003c\/li\u003e\n  \u003cli\u003eEnsure the pluggable wiring connector is fully locked into place before applying power to the K-bus backplane.\u003c\/li\u003e\n  \u003cli\u003eTo optimize noise immunity over long transmission distances (up to 1000 m), use high-quality shielded twisted pair cables.\u003c\/li\u003e\n  \u003cli\u003eMaintain clear ventilation spacing in accordance with the system manual's environmental specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106510233963,"sku":"KS6011","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks6011-kv01oaumlyx.png?v=1776245332","url":"https:\/\/www.plcprotech.com\/id\/products\/beckhoff-ks6011-ks-series-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}