{"product_id":"bently-nevada-330101-02-12-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-02-12-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-02-12-10-02-05\u003c\/strong\u003e is a high-precision, non-contact 8 mm proximity probe designed for the 3300 XL Proximity Transducer System, featuring a 3\/8-24 UNF threaded body without protective armor. This specific configuration is highly customized for applications requiring an unthreaded length of 0.2 inches, an overall case length of 1.2 inches, and a total cable length of 1.0 meter (3.3 feet). Standard coaxial cable is paired with a miniature coaxial ClickLoc connector to deliver clean, uncorrupted signal outputs to compatible Proximitor sensors. Equipped with full CSA, ATEX, and IECEx agency approvals (Option 05), this proximity probe is engineered for permanent installation in challenging hazardous industrial environments, delivering reliable eddy-current displacement and vibration feedback for critical machinery protection.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides non-contact, high-precision radial vibration and axial shaft position measurements.\u003c\/li\u003e\n  \u003cli\u003eFeatures a standard unarmored 3\/8-24 UNF-2A thread design, optimal for installations utilizing protective rigid conduit.\u003c\/li\u003e\n  \u003cli\u003eSpecifies a 0.2-inch unthreaded section and a 1.2-inch overall case length to fit precise machinery physical dimensions.\u003c\/li\u003e\n  \u003cli\u003eIncludes a 1.0-meter (3.3 feet) integrated standard coaxial cable terminated with a gold-plated miniature ClickLoc connector.\u003c\/li\u003e\n  \u003cli\u003eResistant to severe moisture and chemical exposure, featuring a rugged high-pressure seal at the probe tip.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Bently Nevada 3300 XL Proximitor Sensors (330180 series) and standard extension cables.\u003c\/li\u003e\n  \u003cli\u003eDesigned for permanent installation in critical rotating machinery, including turbine bearing housings and gearboxes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial thermal expansion monitoring.\u003c\/li\u003e\n  \u003cli\u003eRotor axial displacement measurement in high-speed compressors, pumps, and fans.\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protection and machinery diagnostics in power generation facilities.\u003c\/li\u003e\n  \u003cli\u003eIndustrial condition monitoring in oil and gas refineries, petrochemical processing plants, and water treatment systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e0.2 inches unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003e1.2 inches overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total integrated cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-02-12-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNon-contact displacement and vibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size and Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A, unarmored case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms (center to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandard Target Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 10% under standard calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap Calibration:\u003c\/strong\u003e Calibrate the physical spacing of the probe (typically set to 1.27 mm or 50 mils) to match the center of the dynamic linear range of the transducer loop.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Protection:\u003c\/strong\u003e Since this model is unarmored, feed the standard coaxial cable through a dedicated metal conduit to prevent mechanical damage or environmental degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding Integrity:\u003c\/strong\u003e Maintain shield grounding at the monitor rack (such as the 3500 system I\/O modules) while ensuring the shield remains isolated at the probe case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Handing:\u003c\/strong\u003e Clean probe connector contact surfaces prior to assembly. Tighten the gold ClickLoc connectors firmly by hand to guarantee proper impedance connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntrinsically Safe (ia):\u003c\/strong\u003e Certified to Ex ia IIC T5...T1 Ga and Ex ia IIIC T90 degC...T280 degC Dc (ATEX\/IECEx); Class I, Division 1, Groups A, B, C, D (CSA).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Incendive (nA\/ec):\u003c\/strong\u003e Certified to Ex nA IIC T5...T1 Gc and Ex ec IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Tip-to-case pressure seal rated for high-differential process seals to prevent leakage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666548060523,"sku":"330101-02-12-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-02-12-10-02-05-3300-xl-8-mm-proximity-probes-sm5jmwlig0f_298c0740-2719-405f-b487-7e836d65b94b.jpg?v=1765440547","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330101-02-12-10-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}