{"product_id":"bently-nevada-330103-02-06-10-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-02-06-10-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 02 (20 mm unthreaded length) and Option 06 (60 mm overall case length) specify this 3300 XL 8 mm metric proximity probe configuration — \u003cstrong\u003e330103-02-06-10-02-00\u003c\/strong\u003e, a non-contacting \u003cstrong\u003eeddy-current proximity probe\u003c\/strong\u003e featuring a metric M10 x 1 thread without mechanical armor. This configuration includes a 1.0 meter (3.3 feet) standard coaxial cable with a miniature coaxial ClickLoc connector and is supplied without agency approvals (Option 00). The M10 x 1 threaded body provides direct compatibility with metric machinery mountings, allowing physical proximity measurement of target shafts.\u003c\/p\u003e\n\n\u003cp\u003eThis specific metric variant contrasts with standard fractional configurations (such as the 3\/8-24 UNF threaded 330101 series) or armored configurations (such as the 330104 series). It operates within the 3300 XL Transducer System, pairing with a 3300 XL Proximitor sensor and a standard extension cable to achieve a total system length of either 5.0 or 9.0 meters. The unarmored 75 ohm triaxial FEP-insulated probe cable maintains a minimum bend radius of 25.4 mm (1.0 inch) for routing in tight machine enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 02 specifies a 20 mm unthreaded length, leaving 40 mm of threaded case length for mounting engagement.\u003c\/li\u003e\n  \u003cli\u003eOption 06 establishes a 60 mm overall case length with an unarmored construction.\u003c\/li\u003e\n  \u003cli\u003eOption 10 provides a 1.0 meter (3.3 feet) total probe lead length.\u003c\/li\u003e\n  \u003cli\u003eOption 02 connector type features a miniature ClickLoc coaxial connector without a connector protector on a standard cable.\u003c\/li\u003e\n  \u003cli\u003eOption 00 indicates that agency approvals are not required for this configuration.\u003c\/li\u003e\n  \u003cli\u003eM10 x 1 metric thread conforms to standard metric mechanical specifications.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip material withstands typical industrial environments.\u003c\/li\u003e\n  \u003cli\u003e75 ohm triaxial fluoroethylene propylene (FEP) insulated cable supports low-noise signal transmission.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis metric probe is used for industrial machinery protection and condition monitoring. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration monitoring on high-speed rotating shafts\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position measurements on steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eEccentricity measurements on generator shafts\u003c\/li\u003e\n  \u003cli\u003eKeyphasor reference and speed measurements on compressors and pumps\u003c\/li\u003e\n  \u003cli\u003eVibration monitoring in petrochemical, power generation, and gas processing plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-02-06-10-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e20 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003e60 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330103-02-06-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1 (metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length (Option A)\u003c\/td\u003e\n      \u003ctd\u003e20 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length (Option B)\u003c\/td\u003e\n      \u003ctd\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThreaded Case Length\u003c\/td\u003e\n      \u003ctd\u003e40 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Lead Length (Option C)\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector (Option D)\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003eStandard 75 ohm triaxial FEP-insulated coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approval (Option E)\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to probe lead maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal DC Resistance\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms (center conductor to outer conductor for 1.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e150 mm x 150 mm x 30 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Torque:\u003c\/strong\u003e Do not exceed the maximum rated torque of 22.6 N-m (200 in-lbf) for standard forward-mounted M10 x 1 probes during installation. The recommended mounting torque is 7.5 N-m (66 in-lbf).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Maintain thread engagement within the maximum limit of 15 mm for M10 x 1 threads to avoid binding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Ensure the 75 ohm triaxial coaxial cable maintains a bend radius of at least 25.4 mm (1.0 inch) to prevent physical or electrical degradation of the conductor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Use a connector protector or self-fusing silicone tape (not inside the machine casing) to prevent moisture or oil ingress at the ClickLoc connection point with the extension cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Adjustment:\u003c\/strong\u003e Adjust the mechanical gap using a feeler gauge or by measuring the DC voltage output at the Proximitor sensor (typically set to a nominal -10 Vdc corresponding to a 1.27 mm mechanical gap on AISI 4140 steel).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848674155,"sku":"330103-02-06-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-02-06-10-02-00-3300-xl-proximity-transducer-cable-3th0ekfg0h0_5c6fe807-67a2-45e3-9d93-7bf807e510b5.jpg?v=1765448991","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330103-02-06-10-02-00-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}