{"product_id":"bently-nevada-330104-00-20-10-01-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-20-10-01-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330104-00-20-10-01-05\u003c\/strong\u003e: 3300 XL 8 mm proximity probe with armored cable, metric M10 x 1 thread, 0 mm unthreaded length, 20 mm case length, 1.0 m total length, coaxial ClickLoc connector with connector protector, and CSA\/ATEX\/IECEx agency approvals. This proximity probe acts as a non-contacting sensor that outputs a voltage proportional to the distance between the probe tip and the observed conductive surface. It is used for both static (position) and dynamic (vibration) measurements on fluid-film bearing machinery, such as turbines, compressors, and generators, in industrial environments.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration includes a flexible stainless steel armor sleeve (Option 00-20-10-01-05) protecting the coaxial cable, preventing damage in harsh operating environments. The integrated ClickLoc connector with a connector protector (Option 01) seals the electrical joint from fluid contamination. The combination of M10 x 1 metric threading with a fully threaded 20 mm case (Option 00-20) allows for direct, secure mounting through machine casings without requiring an unthreaded shoulder. It is fully certified for hazardous area environments with standard CSA, ATEX, and IECEx approvals (Option 05).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Stainless Steel Armor:\u003c\/strong\u003e Integral protective sleeve shields the coaxial cable against abrasion, impact, and cutting in demanding machine environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Threaded Case:\u003c\/strong\u003e Metric M10 x 1 housing has 0 mm unthreaded length (Option 00) and a compact 20 mm overall length (Option 20) for narrow installation locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 1.0 Meter Length:\u003c\/strong\u003e Coaxial lead extends to exactly 1.0 m (3.3 feet) (Option 10) for direct connections to Proximitor sensors or extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protector (Option 01):\u003c\/strong\u003e ClickLoc connector is supplied with an integrated environmental protector sleeve to exclude oil, moisture, and chemical contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Certified:\u003c\/strong\u003e Fully compliant with CSA, ATEX, and IECEx certification standards (Option 05) for intrinsically safe installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardy Tip Encapsulation:\u003c\/strong\u003e Molded polyphenylene sulfide (PPS) tip material resists chemical erosion and high temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used in critical rotating machinery monitoring, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and shaft dynamic motion monitoring on fluid-film bearings.\u003c\/li\u003e\n\u003cli\u003eAxial position and thrust measurement on steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n\u003cli\u003eKeyphasor reference signals and speed measurements.\u003c\/li\u003e\n\u003cli\u003eMachine casing alignment and thermal expansion tracking in power generation, oil and gas, and petrochemical operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eCode Value\u003c\/th\u003e\n\u003cth\u003eDescription \/ Selected Option\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330104-00-20-10-01-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 thread, with armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0 mm unthreaded length (fully threaded case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20 mm case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals (Intrinsically Safe \/ Non-Incendive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330104-00-20-10-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Thread Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 (metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 or 304 Stainless Steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe DC Resistance (R_probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.59 ohms +\/- 0.50 ohms (nominal for 1.0 m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Rated Probe Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeals differential pressure between tip and case (Viton O-ring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.565 N-m (5 in-lbf)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf) probe case to lead connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mm x 150 mm x 30 mm (H x W x D) (packaged\/coiled envelope)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 g (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface Element\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature male coaxial ClickLoc connector (gold-plated brass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded on probe lead (slides over extension cable connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohms triaxial fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.67 mm (0.302 in) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure standard installation practices are followed for optimal transducer performance:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Typically set to -10.0 Vdc (approximately 1.27 mm or 50 mils) against the target surface for a standard -24 Vdc supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Torque:\u003c\/strong\u003e Do not exceed the maximum rated installation torque of 22.6 N-m (200 in-lbf) for M10 x 1 threads; recommended mounting torque is 7.5 N-m (66 in-lbf).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Bend Radius:\u003c\/strong\u003e Maintain a minimum physical bend radius of 25.4 mm (1.0 in) for the armored coaxial cable to avoid interior signal conductor degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Requirements:\u003c\/strong\u003e Standard calibration is for an AISI 4140 steel target. The target surface must be at least 15.2 mm (0.6 in) in diameter to prevent side-view interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis module complies with the following safety and hazardous area standards when installed with the corresponding Proximitor barriers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G; Class III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e II 1 G Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga (Intrinsically Safe)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Fully compliant with relevant European EMC and safety directives.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666642596203,"sku":"330104-00-20-10-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330104-00-20-10-01-05-8-mm-proximity-probes-55hs5xbdnxy_1f810a31-1436-4909-b7a7-c9fd5d51c46b.jpg?v=1765444571","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330104-00-20-10-01-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}