{"product_id":"bently-nevada-330130-060-02-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-060-02-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nOption 060 (6.0 meters cable length) and Option 02 (standard cable with integrated fluorosilicone connector protector) specify this \u003cstrong\u003e3300 XL Standard Extension Cable\u003c\/strong\u003e configuration — \u003cstrong\u003e330130-060-02-05\u003c\/strong\u003e. This cable provides the physical and electrical transmission link between a 3300 XL 8 mm proximity probe and a 3300 XL Proximitor sensor in non-contact displacement monitoring chains. In a complete transducer system, the total length of the probe and extension cable must match the required total system length of the Proximitor sensor (typically 5.0 or 9.0 meters).\n\nThe pre-installed connector protector (Option 02) provides environmental sealing for the gold-plated ClickLoc connector joint, preventing fluid, oil, dust, and moisture ingress in aggressive machinery environments. Option 05 designates the certificate package for explosive or hazardous atmospheres, supporting installation requirements across globally certified process environments.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 060 designates a 6.0 meters (19.7 feet) cable length, forming a matched 7.0 or 9.0 meters system when combined with the corresponding probe.\u003c\/li\u003e\n  \u003cli\u003eOption 02 includes standard cable pre-equipped with a fluorosilicone connector protector to seal and guard the connector joint against environmental contaminants.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides hazardous area approvals including CSA, ATEX, and IECEx certifications.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass and beryllium copper ClickLoc connectors provide positive locking with simple finger-tightening.\u003c\/li\u003e\n  \u003cli\u003eFluorinated Ethylene Propylene (FEP) cable insulation and outer jacket provide chemical, oil, and moisture resistance.\u003c\/li\u003e\n  \u003cli\u003eCable electrical resistance measures 1.32 ohms +\/- 0.21 ohms for the core conductor and 0.39 ohms +\/- 0.08 ohms for the outer jacket conductor over the 6.0 meters length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on high-speed rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eTurbine, generator, compressor, and pump protective monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eEnvironments requiring certified electrical apparatus for explosive or hazardous gas zones.\u003c\/li\u003e\n  \u003cli\u003eMachinery installations exposed to lubricating oils, hydraulic fluids, and severe moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Code\u003c\/th\u003e\n      \u003cth\u003eValue on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330130-060-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable, 6.0 m length, standard cable with connector protector, CSA\/ATEX\/IECEx approved\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Connector Protector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330130-060-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard triaxial coaxial cable with FEP insulation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard cable with connector protector (Option 02)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCore Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.32 ohms +\/- 0.21 ohms (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Jacket Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.39 ohms +\/- 0.08 ohms (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx (Option 05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter of Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.7 mm maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutside Diameter of Connector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.4 mm maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 mm x 200 mm x 30 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector End\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature female coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the miniature male coaxial connector of the proximity probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Connection End\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc\u003c\/td\u003e\n      \u003ctd\u003eConnects to the female coaxial connector of the Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the combined length of the proximity probe and the 6.0 m extension cable equals the calibrated system length specified on the Proximitor sensor label.\u003c\/li\u003e\n  \u003cli\u003eTighten the coaxial ClickLoc connectors finger-tight until they physically click; do not use mechanical tools.\u003c\/li\u003e\n  \u003cli\u003eSlide and fully seat the fluorosilicone connector protector sleeve over the mated connector joint to establish a moisture-proof seal.\u003c\/li\u003e\n  \u003cli\u003eObserve a minimum bend radius of 25.4 mm (1.0 inch) for the FEP coaxial cable during routing.\u003c\/li\u003e\n  \u003cli\u003eSecure the extension cable using non-conductive, oil-resistant cable ties or protective conduit to prevent physical wear and high-voltage interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCSA Certified: Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2; Class III\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Zone 0, Zone 1, and Zone 2 explosive gas atmospheres\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666527613291,"sku":"330130-060-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-060-02-05-extension-cable-0bunup5hoxy_c848148b-b374-40cf-9095-109af2168f0b.jpg?v=1765440300","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330130-060-02-05-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}