{"product_id":"bently-nevada-330173-00-18-10-02-05-3300-5mm-proximity-probe","title":"Bently Nevada 330173-00-18-10-02-05 3300 5mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330173-00-18-10-02-05\u003c\/strong\u003e specifies this unarmored \u003cstrong\u003e3300 5mm Proximity Probe\u003c\/strong\u003e configuration featuring a fully threaded M8 x 1 metric case (0 mm unthreaded length), 180 mm overall case length, 1.0 m total length, standard non-armored FEP cable with miniature coaxial ClickLoc connector, and CSA\/ATEX\/IECEx approvals.\u003c\/p\u003e\n\u003cp\u003eUnlike configurations with protective armor (such as the 330174 series) or integrated connector protectors (Option 01), this specific variant is unarmored and employs standard coaxial cabling with a bare ClickLoc connector (Option 02) for streamlined routing through conduit. The 180 mm metric case (Option 18) provides extended reach in standard machinery mounts where a 1.0 m total length (Option 10) is required to exit the machine casing before connecting to an extension cable.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMetric M8 x 1 Mounting Thread\u003c\/strong\u003e: Unarmored brass or stainless steel body with a 5.2 mm tip diameter, optimized for close-clearance applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e0 mm Unthreaded Length (Option 00)\u003c\/strong\u003e: Fully threaded case allows maximum adjustability within standard threaded brackets or machinery walls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e180 mm Overall Case Length (Option 18)\u003c\/strong\u003e: Long-reach probe body suitable for deep mounting depths in large or double-walled industrial casings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1.0 m Total Cable Length (Option 10)\u003c\/strong\u003e: Offers a 1.0 meter integral cable (standard FEP insulated) for standard connection layouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Miniature Coaxial Connector (Option 02)\u003c\/strong\u003e: Equipped with a miniature male ClickLoc coaxial connector on a standard, non-armored triaxial cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approved (Option 05)\u003c\/strong\u003e: Certified for hazardous locations with multiple agency approvals (CSA, ATEX, IECEx) for intrinsically safe installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePatented TipLoc Molding\u003c\/strong\u003e: Yields a high-strength, robust bond between the polyphenylene sulfide (PPS) probe tip and the stainless steel probe body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVibration monitoring on machinery with limited mounting clearance or smaller shaft diameters (down to 50.8 mm).\u003c\/li\u003e\n  \u003cli\u003eRadial vibration and axial position measurements in fluid-film bearing machines (such as smaller turbines, pumps, and compressors).\u003c\/li\u003e\n  \u003cli\u003eSpeed and Keyphasor phase reference measurements where high-frequency resolution is required.\u003c\/li\u003e\n  \u003cli\u003eHazardous environment installations requiring CSA, ATEX, or IECEx certified intrinsically safe instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330173\u003c\/td\u003e\n      \u003ctd\u003e3300 5 mm Proximity Probe, M8 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18\u003c\/td\u003e\n      \u003ctd\u003e180 mm case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) system total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330173-00-18-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 5 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.2 mm (0.21 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Thread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 x 1 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm (0.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e180 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc male connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard 75-ohm triaxial cable (non-armored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 mm to 2.3 mm (10 mils to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-6.5% typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.038 mm (+\/-1.5 mil) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB with up to 305 m of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe \u0026amp; Cable)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-35 degC to +177 degC (-31 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Case-to-Lead)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e222 N (50 lbf) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (Option 05): ATEX, IECEx, CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Torque\u003c\/strong\u003e: Recommended tightening torque is 5.1 N-m (45 in-lb) for probe case mounting. Do not exceed maximum torque of 7.3 N-m (65 in-lb) to prevent thread or case damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Maintain a minimum cable bend radius of 25.4 mm (1.0 in) along the FEP triaxial cable. Ensure the cable is secured to avoid chafing or mechanical wear from rotating parts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Assembly\u003c\/strong\u003e: Clean coaxial connectors before joining. Hand-tighten the ClickLoc connectors until they \"click\" into place. Do not use tools unless joining non-XL connectors, which require a finger-tight plus 1\/8-turn tight.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Calibration\u003c\/strong\u003e: The system is calibrated for an AISI 4140 steel target. Calibration adjustments may be necessary if monitoring other materials. Ensure the target is at least 15.2 mm (0.6 in) in diameter for accurate scale performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark\u003c\/strong\u003e: Complies with applicable European standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Directive\u003c\/strong\u003e: EN 61000-6-2 and EN 61000-6-4 compliant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05)\u003c\/strong\u003e: CSA, ATEX, and IECEx approved for intrinsically safe Zone 0\/Class I, Division 1 and non-sparking\/ec Zone 2\/Class I, Division 2 applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e: Complies with Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866860395,"sku":"330173-00-18-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330173-00-18-10-02-05-proximitor-sensor-rzjxz15ym3f_f7bf0bcf-4dec-4ad6-a992-c36cd21aa1d7.jpg?v=1765449484","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330173-00-18-10-02-05-3300-5mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}