{"product_id":"bently-nevada-330701-00-15-10-02-05-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330701-00-15-10-02-05 3300 XL Probe Proksimitas 11 mm","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded length), Option 15 (1.5 in overall case length), and Option 02 (miniature coaxial ClickLoc connector, standard cable) specify this 3300 XL 11 mm proximity probe configuration - \u003cstrong\u003e330701-00-15-10-02-05\u003c\/strong\u003e. Operating as a non-contact eddy-current displacement sensor, it measures dynamic shaft vibration and static position on rotating machinery. The unarmored 1\/2-20 UNF threaded steel body mounts directly in threaded machine casings or brackets to capture shaft movement with high precision.\u003c\/p\u003e\n\n\u003cp\u003eThis transducer component is used in 3300 XL 11 mm monitoring systems, pairing with a 330730 extension cable to match the calibration requirements of a 330780 Proximitor sensor. By combining a 1.0 m probe with a 4.0 m extension cable, the system achieves a total electrical length of 5.0 m. The standard ClickLoc coaxial connectors maintain low-resistance signal transfer, while the integrated Locknut with pre-drilled safety wire holes aids mechanical retention under vibration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread configuration: 1\/2-20 UNF-2A standard mount without protective armor.\u003c\/li\u003e\n\u003cli\u003eUnthreaded length: 0.0 inches (fully threaded case) for tight installation clearances.\u003c\/li\u003e\n\u003cli\u003eOverall case length: 1.5 inches for insertion into standard shallow machine housings.\u003c\/li\u003e\n\u003cli\u003eCoaxial cable: 1.0 meter length of 75 ohm triaxial, fluoroethylene propylene (FEP) insulated cable.\u003c\/li\u003e\n\u003cli\u003eConnector type: Miniature coaxial ClickLoc connector without connector protector.\u003c\/li\u003e\n\u003cli\u003eApprovals package: Option 05 offers multiple hazardous area certifications including CSA, ATEX, and IECEx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine shaft vibration and axial position measurement.\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressor rotor position and thrust measurement.\u003c\/li\u003e\n\u003cli\u003eIndustrial pump shaft displacement monitoring.\u003c\/li\u003e\n\u003cli\u003eGearbox shaft motion and dynamic mechanical runout assessment.\u003c\/li\u003e\n\u003cli\u003eKeyphasor phase reference and speed measurements on rotating machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330701-00-15-10-02-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm proximity probe, 1\/2-20 UNF thread, standard mount, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in (38 mm) overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) total probe length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (160 mils), beginning at 0.5 mm (20 mils) from target (from 0.5 to 4.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 V\/mm (100 mV\/mil) with 10% tolerance (including interchangeability error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 8 kHz (+0, -3 dB typical) with up to 305 meters of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel target (flat surface, 30.5 mm\/1.2 in minimum diameter recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe dc Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.9 ohms +\/- 0.5 ohms (center conductor to outer conductor for 1.0 m probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass ClickLoc coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lb) probe case to probe lead maximum rated pull strength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.2 N-m (400 in-lb) maximum rated torque; 15.2 N-m (133 in-lb) recommended torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePositioning the probe requires establishing the standard 2.5 mm (100 mils) gap using a voltmeter to measure the corresponding -10 Vdc bias output. Standard mount 1\/2-20 UNF threaded probes must be locked in place using the supplied locknut. The locknut has pre-drilled holes for safety wire to prevent loose rotation. The minimum bend radius for the probe cable is 25.4 mm (1.0 inch) to protect the internal triaxial conductors. Hand-tighten coaxial ClickLoc connectors; do not exceed 0.565 N-m (5 in-lb) of torque if utilizing mechanical tools. Exposing the probe to temperatures below -34 degC (-30 degF) may cause premature failure of the pressure seal.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eApproved under Option 05 (Multiple Approvals) for hazardous areas, featuring certifications from CSA, ATEX, and IECEx. Under intrinsically safe installations (Ex ia IIC T4\/T5 Ga), install the system with approved zener barriers or galvanic isolators per Bently Nevada drawing 141092. For non-incendive installations (Ex nA\/ec IIC T4\/T5 Gc), refer to drawing 140979. The product complies with European EMC Directive 2014\/30\/EU, EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions), and RoHS Directive 2011\/65\/EU.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666545504619,"sku":"330701-00-15-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330701-00-15-10-02-05-3300-xl-11-mm-proximity-probes-0d23syu3o5k_2d0f0d9e-3fbf-4326-841c-925c4d52a6fe.jpg?v=1765440518","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330701-00-15-10-02-05-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}