{"product_id":"bently-nevada-330703-00-100-10-11-cn-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330703-00-100-10-11-CN 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nOption 00 (0 mm unthreaded length) and Option 11 (ClickLoc connector with protector, FluidLoc cable) specify this metric \u003cstrong\u003e3300 XL 11 mm Proximity Probe\u003c\/strong\u003e configuration — \u003cstrong\u003e330703-00-100-10-11-CN\u003c\/strong\u003e. This configuration is built for metric mounting environments requiring a threaded case diameter of M14 x 1.5 and an overall case length of 100 mm. The unarmored assembly is supplied with a 1.0 meter (3.3 feet) integrated FluidLoc cable that acts as an oil-tight barrier, preventing fluid migration through the internal probe structure. \n\nThe addition of the -CN suffix guarantees compliance with Chinese NEPSI and CCC hazardous area certifications, optimizing the probe for installation in dangerous industrial plants. As part of the 3300 XL 11 mm system, this probe has a longer linear range than standard 8 mm probes, making it suitable for axial position measurements, differential expansion, or radial vibration on steam turbines, compressors, and rotating machinery.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 specifies a 0 mm unthreaded length on a fully threaded M14 x 1.5 stainless steel case.\u003c\/li\u003e\n  \u003cli\u003eOption 100 provides a 100 mm overall case length for metric mounting.\u003c\/li\u003e\n  \u003cli\u003eOption 10 sets a 1.0 meter (3.3 feet) integrated probe cable length.\u003c\/li\u003e\n  \u003cli\u003eOption 11 designates a miniature coaxial ClickLoc connector with an integrated fluorosilicone connector protector.\u003c\/li\u003e\n  \u003cli\u003eFluidLoc cable technology prevents fluid leakage and migration along the inner core of the cable.\u003c\/li\u003e\n  \u003cli\u003eSuffix -CN incorporates pre-verified NEPSI and CCC China hazardous area approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRamp differential expansion measurements on steam turbines.\u003c\/li\u003e\n  \u003cli\u003eThrust and axial position measurements on high-speed rotating shafts.\u003c\/li\u003e\n  \u003cli\u003eRadial vibration and shaft position tracking on fluid-film bearing machinery.\u003c\/li\u003e\n  \u003cli\u003eRod position and rod drop monitoring in heavy reciprocating compressors.\u003c\/li\u003e\n  \u003cli\u003eTachometer, phase reference (Keyphasor), and zero-speed measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Probe, M14 x 1.5 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n      \u003ctd\u003e100 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuffix -CN\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-CN\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI and CCC certifications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703-00-100-10-11-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 mm Eddy-Current Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% including interchangeability\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBest Fit Straight Line (DSL) Deviation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.10 mm (+\/-4 mils) at standard temperatures; less than +\/-0.15 mm (+\/-6 mils) at extended temperatures\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel (flat surface, minimum 30.5 mm diameter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz (+0, -3 dB typical) with up to 305 meters of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnarmored 75 ohm triaxial, FEP insulated, FluidLoc style\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Torque (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Torque (Recommended)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e21.1 N-m (187 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial with fluorosilicone protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximitor Sensor (330780), 3300 XL 11 mm Extension Cables (330730)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the coaxial connector outer shield is isolated from the machine housing to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use twisted, shielded field wiring between the Proximitor sensor and the monitor, grounding the shield only at the monitor end.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) for all probe and extension cables. Secure cables properly to prevent whipping or dynamic wear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e Set the initial probe gap to the recommended 2.5 mm (100 mils) using a digital voltmeter or thickness gauges.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Hand-tighten the miniature coaxial ClickLoc connector and ensure the integrated fluorosilicone protector covers the junction fully to shield against moisture and contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEPSI \u0026amp; CCC:\u003c\/strong\u003e Certified under the China hazardous area approval package (-CN suffix).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Compliant with European EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e Tested to EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666622968171,"sku":"330703-00-100-10-11-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-00-100-10-11-cn-3300-xl-11-mm-proximity-probes-ggff0v2ior1_4c22dd3f-adca-4be8-9e30-e2a5ab8e0b00.jpg?v=1765444283","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330703-00-100-10-11-cn-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}