{"product_id":"bently-nevada-330704-000-060-10-02-00-3300-xl-11-mm-proximity-probe","title":"Probe Proksimitas Bently Nevada 330704-000-060-10-02-00 3300 XL 11 mm  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330704-000-060-10-02-00\u003c\/strong\u003e is an eddy-current non-contacting displacement probe used inside 3300 XL 11 mm proximity transducer systems. This specific configuration features an M14 x 1.5 metric thread with integrated stainless steel armor, a 0 mm unthreaded length (Option 000), and a 60 mm overall case length (Option 060). The probe has a total length of 1.0 meter (3.3 feet), terminated with a standard miniature coaxial ClickLoc male connector without agency approvals (Option 00).\u003c\/p\u003e\n\n\u003cp\u003eOperating as a sensor within the 3300 XL 11 mm transducer line, this probe provides a nominal output of 3.94 V\/mm (100 mV\/mil) when paired with a matching Proximitor sensor and extension cable. The integrated flexible AISI 302 stainless steel armor protects the 75 ohm triaxial cable from physical wear, abrasion, and harsh machine environment conditions. This metric armor variant is used in installations requiring physical shielding and direct mechanical mounting on rotating machinery such as turbines, compressors, and pumps.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM14 x 1.5 threaded case made of corrosion-resistant AISI 304 stainless steel.\u003c\/li\u003e\n  \u003cli\u003eIntegrated flexible AISI 302 stainless steel armor with protective FEP outer jacket.\u003c\/li\u003e\n  \u003cli\u003eOption 000 specifies a fully threaded case length with 0 mm of unthreaded probe body.\u003c\/li\u003e\n  \u003cli\u003eOption 060 provides a 60 mm overall case length for specific insertion requirements.\u003c\/li\u003e\n  \u003cli\u003eOption 10 total probe length of 1.0 meter (3.3 feet) for direct cable coupling.\u003c\/li\u003e\n  \u003cli\u003eOption 02 ClickLoc miniature coaxial male connector for a locking, vibration-resistant connection.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip material for high environmental and chemical resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used for monitoring critical rotating machinery parameters, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and axial (thrust) position on fluid film bearing machines.\u003c\/li\u003e\n  \u003cli\u003eRamp differential expansion measurements on steam turbines.\u003c\/li\u003e\n  \u003cli\u003eRod position or rod drop measurements on reciprocating compressors.\u003c\/li\u003e\n  \u003cli\u003eTachometer, speed, and zero speed measurements.\u003c\/li\u003e\n  \u003cli\u003ePhase reference (Keyphasor) signal generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode\u003c\/th\u003e\n      \u003cth\u003eConfiguration Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330704\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Probe, M14 x 1.5 thread, with stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e60 mm case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eAgency approvals not required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330704-000-060-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Linear Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), begins at approx 0.5 mm (20 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eScale Factor (Nominal)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e11 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Thread Size\u003c\/td\u003e\n      \u003ctd\u003eM14 x 1.5 metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Material\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 SST with FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Specification\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial male connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePressure Sealing\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring differential pressure seal between tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum)\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following installation criteria to avoid hardware damage and achieve proper signal response:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e The maximum allowable thread engagement length for M14 x 1.5 probe cases is 21 mm. Exceeding this length may cause mechanical binding during installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Torque:\u003c\/strong\u003e The recommended installation torque for M14 x 1.5 probe cases is 21.1 N-m (187 in-lb). Do not exceed the maximum rated limit of 63.3 N-m (560 in-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Tightening:\u003c\/strong\u003e Ensure connections are clean and dry. Finger-tighten the miniature coaxial ClickLoc connectors, or use a connector torque wrench limited to 0.565 N-m (5 in-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Maintain a minimum cable bend radius of 25.4 mm (1.0 in) for the armored probe cable during routing to avoid internal conductor fatigue.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666632765803,"sku":"330704-000-060-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330704-000-060-10-02-00-3300-xl-11-mm-proximitor-sensor-pf15xsoth0v_284dad0a-d739-4be8-b42a-c019fe3d26db.jpg?v=1765444420","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330704-000-060-10-02-00-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}