{"product_id":"bently-nevada-330730-080-00-05-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-00-05 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330730-080-00-05\u003c\/strong\u003e specifies this \u003cstrong\u003e3300 XL 11 mm extension cable\u003c\/strong\u003e configuration, featuring an 8.0-meter cable length, standard unarmored coaxial construction, and multiple hazardous area agency approvals. This cable serves as a link within the non-contact eddy-current transducer system, connecting the proximity probe to the Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eUnlike variants that incorporate stainless steel armor or connector protectors, this standard triaxial cable configuration maintains a compact outer diameter of 3.7 mm, maximizing flexibility during installation inside conduits. It operates under challenging conditions, withstanding temperatures from -52 degC to +177 degC while preserving low electrical loss and consistent capacitive properties required for vibration and position monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length\u003c\/strong\u003e: 8.0 meters (26.2 feet) of triaxial cable matching standard system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type\u003c\/strong\u003e: Standard unarmored triaxial cable featuring chemical-resistant fluoroethylene propylene (FEP) insulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Design\u003c\/strong\u003e: Miniature coaxial ClickLoc connectors at each end for standard, tool-free coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e: Multiple hazardous area certifications under Option 05, including CSA, ATEX, and IECEx.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Flexibility\u003c\/strong\u003e: 25.4 mm minimum bend radius allows installation within restricted machinery spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is used in 3300 XL 11 mm proximity transducer systems on rotating machinery, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine shaft vibration and axial position monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressor rotor position sensing.\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection in oil, gas, chemical, and power generation facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330730-080-00-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Connector and Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable (unarmored, no connector protector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, and others)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330730-080-00-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated, unarmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outer Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connectors (male and female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance (RCORE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 +\/- 0.2 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Conductor Resistance (RJACKET)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 +\/- 0.5 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 N (60 lb) from probe lead to extension cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Probe (1.0 m length) and 3300 XL 11 mm Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Control\u003c\/strong\u003e: Route the cable to ensure no bend is tighter than the 25.4 mm (1.0 inch) minimum limit, protecting the internal coaxial structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Security\u003c\/strong\u003e: Connect ClickLoc coaxial joints hand-tight. Do not apply tools that could exceed the maximum torque limit of 0.565 N-m (5 in-lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Mitigation\u003c\/strong\u003e: Ensure connections are protected from oil and moisture. Avoid silicone tape in environments where probe-to-extension cable joints are exposed to turbine oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Matching\u003c\/strong\u003e: This 8.0-meter cable must be matched with a 1.0-meter probe to align with a 9.0-meter Proximitor Sensor calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Type\u003c\/th\u003e\n\u003cth\u003eStandard or Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Classifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx) for intrinsically safe (ia) and non-incendive (nA, ec) installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Directive 2011\/65\/EU; China RoHS (15-year EFUP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2 (HFT = 0), SIL 3 (HFT = 1) compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaritime Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS Rules for Conditions of Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865811819,"sku":"330730-080-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-080-00-05-extension-cable-ppjos1d0p0d_4cb5cfc9-5229-43c3-82ec-f46c04a54667.jpg?v=1765449442","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330730-080-00-05-3300-xl-11-mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}