{"product_id":"bently-nevada-330851-02-000-050-50-00-05-3300-xl-25-mm-proximity-probe","title":"Bently Nevada 330851-02-000-050-50-00-05 3300 XL Probe Proksimitas 25 mm","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330851-02-000-050-50-00-05\u003c\/strong\u003e: 3300 XL 25 mm proximity probe featuring an M30x2 threaded metric case with 5.0 meters of integrated FluidLoc coaxial cable for non-contacting, large-target displacement measurement. This specific configuration is supplied with 0 mm unthreaded length, a 50 mm overall case length, no protective armor, and Multiple Approvals agency certification (Option 05) for hazardous industrial zones. It functions in the 3300 XL 25 mm Transducer System, converting mechanical position changes into proportional voltage signals.\u003c\/p\u003e\n\n\u003cp\u003eUnlike configurations using smooth cases or unthreaded case options, this variant utilizes an M30x2 threaded body to secure the probe directly into threaded ports. The 5.0-meter system length allows direct connection to a panel- or DIN-rail-mounted Proximitor sensor without requiring an intermediary extension cable, minimizing connections in heavy-duty environments. The non-armored design provides flexibility for standard conduit routing, and the multiple approvals package includes ATEX, IECEx, and North American hazardous area certifications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 02 specifies an M30x2 threaded metric case made of AISI 304 stainless steel.\u003c\/li\u003e\n  \u003cli\u003eOption 000 designates 0 mm unthreaded length for maximum thread contact in standard mounting holes.\u003c\/li\u003e\n  \u003cli\u003eOption 050 provides a 50 mm overall case length, ideal for standard industrial brackets.\u003c\/li\u003e\n  \u003cli\u003eOption 50 provides a 5.0-meter integrated FluidLoc triaxial probe cable with perfluoroalkoxyethylene (PFA) insulation.\u003c\/li\u003e\n  \u003cli\u003eOption 00 specifies a non-armored cable configuration for streamlined conduit installations.\u003c\/li\u003e\n  \u003cli\u003eOption 05 offers multiple hazardous area agency approvals, including ATEX, IECEx, and North American certifications.\u003c\/li\u003e\n  \u003cli\u003eLarge-target capability measures up to 12.7 mm (500 mils) of linear displacement when used with a 3300 XL 25 mm Proximitor.\u003c\/li\u003e\n  \u003cli\u003ePEEK (Polyetheretherketone) probe tip provides structural integrity and resistance to extreme temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine thrust position monitoring\u003c\/li\u003e\n  \u003cli\u003eLarge shaft axial displacement measurement\u003c\/li\u003e\n  \u003cli\u003eDifferential expansion (DE) monitoring on mid-to-large-size steam turbine generators\u003c\/li\u003e\n  \u003cli\u003eRod-drop monitoring in reciprocating compressors\u003c\/li\u003e\n  \u003cli\u003eNon-contacting displacement measurements on rotating machines with large shaft diameters or targets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330851-02-000-050-50-00-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Probe, M30x2 threaded case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA: Probe Case Type\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eM30x2 thread (metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB: Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC: Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e050\u003c\/td\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD: Total Length\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 metres (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE: Armor Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo Armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eF: Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx, NEPSI)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330851-02-000-050-50-00-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.7 mm (500 mils), from approximately 0.63 mm to 13.33 mm (25 to 525 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (Sensitivity)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyetheretherketone (PEEK)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, perfluoroalkoxyethylene (PFA) insulated FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM30x2 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Armor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo Armor (non-armored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe dc Resistance (5.0 m Lead)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 +\/- 0.8 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Minimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e61 mm (2.4 inches) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-35 to +200 degC (-31 to +392 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Term Temperature Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+250 degC (+482 degF) maximum for less than 24 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 pounds) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e68 N-m (50 ft-lb); maximum rated 163 N-m (120 ft-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the probe is mounted perpendicular to the target surface.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum recommended target size of 61 mm (2.4 in) diameter to prevent reduced linear range.\u003c\/li\u003e\n  \u003cli\u003eUse the recommended installation torque of 68 N-m (50 ft-lb) for the M30x2 threaded metric body. Do not exceed 163 N-m (120 ft-lb).\u003c\/li\u003e\n  \u003cli\u003eProtect cable connectors from environmental moisture and contaminants; using silicone self-fusing tape or connector protectors is highly recommended.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 inch) for the triaxial FluidLoc coaxial cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga, Ex ia IIIC T90 degC...T280 degC Dc, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA\/cNRTLus:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, and D, Class II, Groups E, F, and G, Class III; Class I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European CE mark requirements for electromagnetic compatibility and safety.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666618184043,"sku":"330851-02-000-050-50-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330851-02-000-050-50-00-05-3300-xl-25-mm-proximity-probe-1vzvo0eodkw_64f39695-e182-41ae-a057-a0c43d381f23.jpg?v=1765444224","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330851-02-000-050-50-00-05-3300-xl-25-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}