{"product_id":"bently-nevada-330880-00-20-038-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330880-00-20-038-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (no probe; Proximitor sensor only) and Option 20 (2.0 in standoff adapter) specify this 3300 XL PROXPAC integrated proximity transducer configuration - \u003cstrong\u003e330880-00-20-038-00-02\u003c\/strong\u003e. Designed with a 3.8 in probe penetration length (Option 038), the assembly provides a self-contained monitoring solution by placing the 3300 XL Proximitor sensor directly in the housing lid, eliminating the need for separate Proximitor housings and extension cables. This model does not include a probe sleeve fitting kit (Option 00) and features a standard 3\/4-14 NPT mounting thread (Option 02) for secure mechanical installation.\u003c\/p\u003e\n\u003cp\u003eBy combining the sensor and termination enclosure into a single, compact unit, this configuration reduces field wiring and installation complexity. Unlike configurations that include an integrated 3300 XL 8 mm probe or have hazardous area approvals, the 330880-00-20-038-00-02 serves as a non-approved replacement or customizable baseline housing assembly where the target probe and external conduit options are selected separately.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Proximitor Sensor:\u003c\/strong\u003e Cover-mounted 3300 XL Proximitor eliminates the need for separate signal conditioning housings and extension cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePolyphenylene Sulfide (PPS) Housing:\u003c\/strong\u003e Molded thermoplastic body reinforced with glass and conductive fibers offers excellent electrostatic dissipation and environmental protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Mechanical Adjustability:\u003c\/strong\u003e Features a 2.0 in (51 mm) standoff adapter length and 3.8 in (97 mm) probe penetration length to match specific machine case geometries.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Mounting Interface:\u003c\/strong\u003e Furnished with a robust 3\/4-14 NPT mounting thread for rigid connection to the machine case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType 4X and IP66 Protection:\u003c\/strong\u003e Verified casing seals isolate the internal probe and electronics from hose-directed water and highly corrosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe integrated configuration is suitable for a variety of heavy-duty rotating machinery monitoring applications, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft radial vibration measurements on steam turbines, gas turbines, and large compressors\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position monitoring on high-speed pumps and industrial gearboxes\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery protection where a compact, direct-to-monitor field wiring setup is required\u003c\/li\u003e\n  \u003cli\u003eCorrosive or high-humidity environments where metal enclosures are prone to degradation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-00-20-038-00-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly (English Version)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo probe; Proximitor sensor without approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 in (51 mm) standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e038\u003c\/td\u003e\n      \u003ctd\u003e3.8 in (97 mm) probe penetration length (0.1 in increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (Required if ordering Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330880-00-20-038-00-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatible Probe Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (with up to 305 metres of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils) with 3300 XL 8 mm probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMinimum: 50.8 mm (2.0 in); Recommended Minimum: 76.2 mm (3.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGrounding Liner Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Isolation Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eExtra Soft Cellular Silicone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Environment Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temp Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing\/Sensor Operating Temp Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRetaining Nut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Sleeve Locknut Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor correct mounting and long-term mechanical reliability, observe the following engineering recommendations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the total combined \"B\" plus \"C\" dimension does not exceed 305 mm (12 in) without providing additional probe sleeve support near the probe tip to avoid resonances.\u003c\/li\u003e\n  \u003cli\u003eEnsure the O-rings are lubricated and properly seated before assembly to maintain the IP66 ingress protection rating.\u003c\/li\u003e\n  \u003cli\u003ePrevent water and solvent accumulation inside the housing cover by routing field wiring through conduit that slopes away from the housing.\u003c\/li\u003e\n  \u003cli\u003eDo not expose the probe tip to environments below -34 degC (-29 degF) prior to machine startup, as low temperatures may affect the pressure seal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n      \u003cth\u003eCompliance Classification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Mark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eComplies with European Union Directives\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and NEMA Type 4X verified housing cover design\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529644907,"sku":"330880-00-20-038-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330880-00-20-038-00-02-proxpac-xl-proximity-transducer-hkz5avir5a4_74ec7400-30cf-4191-a9ec-ca47473077cd.jpg?v=1765440336","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330880-00-20-038-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}