{"product_id":"bently-nevada-330901-10-24-10-02-00-3300-nsv-proximity-probes","title":"Bently Nevada 330901-10-24-10-02-00 3300 NSv Proximity Probes","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eA partially unthreaded 1\/4-28 UNF steel probe body with 1.0 inch of unthreaded length (Option 10), a 2.4-inch overall case length (Option 24), and a 1.0-meter standard cable (Option 10) defines this 3300 XL NSv proximity transducer configuration — \u003cstrong\u003e330901-10-24-10-02-00\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration does not include a stainless steel armor jacket or connector protector (Option 02) and is designed for applications where hazardous area approvals are not required (Option 00). In contrast to armored configurations such as the 330902 series or configurations featuring FluidLoc cable technology (Option 11 or 12), this unarmored standard-cable model provides a lightweight, highly flexible solution for tight installation spaces with reduced target area geometry.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\/4-28 UNF Thread Configuration:\u003c\/strong\u003e Manufactured with standard threads and no protective armor (330901 series).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.0 Inch Unthreaded Length (Option 10):\u003c\/strong\u003e Matches specified mounting requirements where a portion of the probe body must remain unthreaded.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.4-Inch Case Length (Option 24):\u003c\/strong\u003e Designed for standard deep-port insertion installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.0-Meter Total Length (Option 10):\u003c\/strong\u003e Provides 1.0 meter (39 inches) of integrated coaxial cable to connect directly to a 330930 extension cable or compatible 330980 Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Miniature Coaxial Connector (Option 02):\u003c\/strong\u003e Standard ClickLoc male connector without connector protector on standard 75-ohm cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Agency Approvals Required (Option 00):\u003c\/strong\u003e Suitable for non-hazardous area environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv Proximity Transducer System is designed for machinery with small target diameters or limited mounting clearance, where standard 8 mm probes cannot be installed due to space constraints. Typical installations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVibration and position measurements on small-bore rotating machinery\u003c\/li\u003e\n\u003cli\u003eRadial vibration and axial position sensing on aeroderivative gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressors and pumps with small shafts (under 30 mm)\u003c\/li\u003e\n\u003cli\u003eTurbine auxiliary systems and gearboxes\u003c\/li\u003e\n\u003cli\u003eFluid-film bearing monitoring in space-restricted environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription \/ Configuration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330901-10-24-10-02-00\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 in (25 mm) unthreaded length (ordered in 0.1-inch increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e2.4 in (61 mm) overall case length (ordered in 0.1-inch increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 inches) total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (no connector protector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330901-10-24-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Thread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF-2A, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 in (25.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 in (61.0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc male connector (gold-plated brass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Jacket \/ Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75-ohm coaxial standard cable, unarmored (2.8 mm max outside diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils); starts at 0.25 mm (10 mils) to 1.75 mm (70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical (with up to 305 m \/ 1,000 ft of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.26 mm (0.207 in) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Size Limit (Flat Target)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 8.9 mm (0.35 in) diameter; recommended minimum 13 mm (0.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Resistance (Probe Center to Outer)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 ohms +\/-0.5 ohms (for 1.0 m probe length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible (tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Sealing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring differential pressure seal between tip and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Recommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 N m (45 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Minimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper mechanical and electrical installation is critical to ensure accurate proximity probe measurements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Torque Limit:\u003c\/strong\u003e When installing the 1\/4-28 UNF probe case, do not exceed the maximum recommended torque of 5.1 N m (45 in lb) to prevent thread or casing damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Bend Radius:\u003c\/strong\u003e Maintain a minimum coaxial cable bend radius of 25.4 mm (1.0 in) during cable routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Ensure proper thread engagement limits (typical maximum thread engagement for a 1\/4-28 UNF probe is 0.375 inches) to prevent physical contact issues or binding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Handling:\u003c\/strong\u003e ClickLoc connectors must be joined finger-tight. Ensure connectors are clean and dry before connection. Installing a connector protector or using silicone tape (not recommended in oil-exposed environments) is advised to prevent fluid ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gapping:\u003c\/strong\u003e Set the initial probe gap to approximately 1.0 mm (40 mils) using a feeler gauge or by monitoring the Proximitor output voltage (typically -9.0 Vdc to -10.0 Vdc) for centering in the linear range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration (Option 00) is designated for applications where specialized hazardous area safety approvals are not required. For applications requiring intrinsic safety, non-incendive, or zone certifications (such as ATEX, IECEx, or CSA), specify the Option 05 (Multiple Approvals) configuration.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666529775979,"sku":"330901-10-24-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-10-24-10-02-00-3300-nsv-proximity-probes-y5yirl1fi3d_e557b226-ec98-45e8-af82-6882aa5ec3da.jpg?v=1765440339","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330901-10-24-10-02-00-3300-nsv-proximity-probes","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}