{"product_id":"bently-nevada-330902-00-30-05-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330902-00-30-05-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded length) and Option 30 (3.0 in overall case length) specify the physical configuration of this 3300 NSv armored proximity probe — \u003cstrong\u003e330902-00-30-05-02-00\u003c\/strong\u003e. This non-contacting eddy-current displacement sensor features flexible stainless steel armor to shield the coaxial cable from abrasion, cutting, and mechanical damage in tight installation spaces. Configured with a 0.5-meter total length (Option 05) and a standard ClickLoc coaxial connector (Option 02), this probe provides shaft vibration and position monitoring in standard industrial environments without agency approval requirements (Option 00).\u003c\/p\u003e\n\n\u003cp\u003eUnlike unarmored configurations such as the 330901 series, the \u003cstrong\u003e330902-00-30-05-02-00\u003c\/strong\u003e probe has a robust stainless steel conduit surrounding the FEP-insulated coaxial line. This mechanical protection is suited for application environments where routing pathways expose the cabling to physical contact or abrasive surfaces. Operating within the 3300 XL NSv Proximity Transducer System, this probe pairs with the 330980 Proximitor Sensor and 330930 extension cable to perform displacement measurements on rotating shafts with small target diameters or limited clearances.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1\/4-28 UNF threaded case with a 3.0 inch overall case length (Option 30) and a fully threaded 0.0 inch unthreaded length (Option 00).\u003c\/li\u003e\n  \u003cli\u003eFlexible stainless steel armor protects the 75 ohm coaxial, FEP-insulated probe cable from mechanical wear and abrasive environments.\u003c\/li\u003e\n  \u003cli\u003e0.5 meter (20 inch) total cable length (Option 05) for compact installation envelopes.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector (Option 02) features gold-plated brass construction to prevent connection loosening.\u003c\/li\u003e\n  \u003cli\u003eNo agency approvals required (Option 00) for standard non-hazardous industrial locations.\u003c\/li\u003e\n  \u003cli\u003eTipLoc molding process provides a bond between the polyphenylene sulfide (PPS) probe tip and the AISI 304 stainless steel case.\u003c\/li\u003e\n  \u003cli\u003eCableLoc design provides up to 220 N (50 lb) of pull strength between the probe cable and the sensor body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position monitoring on high-speed industrial compressors and pumps.\u003c\/li\u003e\n  \u003cli\u003eSmall-bore machinery and aeroderivative gas turbines with limited physical installation clearance.\u003c\/li\u003e\n  \u003cli\u003eRotating machinery with target diameters smaller than 20 mm (0.8 in) where side-view interference must be minimized.\u003c\/li\u003e\n  \u003cli\u003eIndustrial fans, blowers, and process gearboxes requiring armored cable protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330902-00-30-05-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e30\u003c\/td\u003e\n      \u003ctd\u003e3.0 in (30 tenths of an inch) threaded case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (20 inches) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330902-00-30-05-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNon-contacting eddy-current displacement probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible stainless steel armor surrounding coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 in (76.2 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 meters (20.0 inches)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over 1.5 mm range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Input Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (at 12 mA maximum consumption)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) maximum rated from case to lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.1 N m (45 in lb) rated; 7.3 N m (65 in lb) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInitially thread the probe case by hand, then tighten to the recommended case torque of 5.1 N m (45 in lb). Do not exceed the maximum limit of 7.3 N m (65 in lb) to prevent thread stripping or housing distortion.\u003c\/li\u003e\n  \u003cli\u003eEnsure routing paths avoid sharp bends in the armor, keeping to a minimum bend radius of 25.4 mm (1.0 in).\u003c\/li\u003e\n  \u003cli\u003eSet the probe-to-target physical gap to 1.0 mm (40 mils) during machine outage using standard gauge tools to establish a baseline.\u003c\/li\u003e\n  \u003cli\u003eApply protective self-fusing silicone tape or install matching connector protectors at coaxial joints to prevent moisture or cutting fluids from compromising the high-frequency electrical signal.\u003c\/li\u003e\n  \u003cli\u003eVerify that the total combined electrical length of the probe and extension cable matches the calibration requirements of the connected Proximitor Sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark: Compliant (when integrated within a certified 3300 XL NSv system)\u003c\/li\u003e\n  \u003cli\u003eRoHS: Compliant\u003c\/li\u003e\n  \u003cli\u003eAgency Approvals: Option 00 specifies that no hazardous area certifications are provided. For explosion-proof or intrinsically safe applications, select an option 05 configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666639483243,"sku":"330902-00-30-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330902-00-30-05-02-00-3300-nsv-proximity-probes-zu1bflpo3o0_5d3d75d7-0f80-4372-8cbe-bce12f39c5bc.jpg?v=1765444530","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330902-00-30-05-02-00-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}