{"product_id":"bently-nevada-330902-05-20-10-02-05-3300-nsv-proximity-probes","title":"Bently Nevada 330902-05-20-10-02-05 3300 NSv Proximity Probes","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 05 (0.5 in unthreaded length) and Option 20 (2.0 in overall case length) specify this 3300 NSv proximity probe configuration with stainless steel armor — \u003cstrong\u003e330902-05-20-10-02-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis eddy-current sensor is part of the Bently Nevada 3300 XL NSv proximity transducer system, used for shaft vibration and axial position measurement on high-speed rotating machinery with limited target geometry. The probe features integrated stainless steel armor to shield the coaxial cable from physical damage, making it suitable for environments with potential mechanical abrasion. It operates in conjunction with a 330980 Proximitor sensor and a 330930 extension cable to produce a standard voltage output proportional to the gap between the probe tip and the target material.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThread type: 1\/4-28 UNF threaded case with stainless steel armor for physical protection.\u003c\/li\u003e\n  \u003cli\u003eUnthreaded length: 0.5 inches (Option 05) to accommodate specific mounting configurations.\u003c\/li\u003e\n  \u003cli\u003eOverall case length: 2.0 inches (Option 20) standard mount design.\u003c\/li\u003e\n  \u003cli\u003eTotal length: 1.0 meter (39 inches) (Option 10) integrated cable.\u003c\/li\u003e\n  \u003cli\u003eConnector option: Miniature coaxial ClickLoc connector (Option 02) for standard cable termination.\u003c\/li\u003e\n  \u003cli\u003eAgency approvals: Option 05 designates multiple hazardous area certifications including CSA, ATEX, and IECEx.\u003c\/li\u003e\n  \u003cli\u003eMeasurement technology: Non-contact eddy-current sensor with an Average Scale Factor of 7.87 V\/mm (200 mV\/mil).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSmall-bore machinery with restricted mounting space.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed centrifugal compressors and expanders.\u003c\/li\u003e\n  \u003cli\u003eRadial vibration and axial position monitoring in tight clearance areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330902\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Probe, 1\/4-28 UNF thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 in unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 inches) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx hazardous area certifications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330902-05-20-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated flexible AISI 302 stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), beginning at 0.25 mm (10 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.1 N m (45 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.3 N m (65 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAvoid exceeding the maximum recommended case torque of 7.3 N m (65 in-lb) to prevent thread and casing damage.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) for the armored cable during installation routing.\u003c\/li\u003e\n  \u003cli\u003eRecommended gap setting is 1.0 mm (40 mils) for optimal positioning in the linear range.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum separation of 25 mm (1.0 in) between adjacent transducer tips to prevent electromagnetic cross-talk.\u003c\/li\u003e\n  \u003cli\u003eConnectors must be protected or insulated to ensure moisture exclusion in high humidity environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntrinsically Safe (ia):\u003c\/strong\u003e Certified for Class I, Zone 0, Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Incendive \/ Increased Safety (nA, ec):\u003c\/strong\u003e Certified for Class I, Zone 2, Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A, B, C, D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European Community Directives including EMC Directive 2014\/30\/EU and RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Environment Friendly Use Period (EFUP) of 15 years.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified with Hardware Fault Tolerance (HFT) of 0, and SIL 3 with HFT of 1 when deployed in redundant configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666533708139,"sku":"330902-05-20-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330902-05-20-10-02-05-3300-nsv-proximity-probes-xgniqgtvqfi_0d0a597a-9d73-47c4-8e08-04d5fed8bc43.jpg?v=1765440391","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330902-05-20-10-02-05-3300-nsv-proximity-probes","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}