{"product_id":"bently-nevada-330908-00-36-05-02-05-05-3300-nsv-proximity-probe","title":"Probe Proximity Bently Nevada 330908-00-36-05-02-05-05 3300 NSv  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded 3\/8-24 UNF steel probe body (Option 00) with a 3.6-inch overall case length (Option 36) and a 0.5-meter total probe length (Option 05) specifies this exact \u003cstrong\u003e330908-00-36-05-02-05-05 3300 NSv Proximity Probe\u003c\/strong\u003e configuration. Used in compact machinery applications with restricted installation space or small shaft targets, this proximity probe provides non-contact displacement measurements for critical shaft vibration and axial position parameters.\u003c\/p\u003e\n\n\u003cp\u003eThis unarmored base configuration (330908) includes a miniature coaxial ClickLoc connector on standard FEP-insulated cable (Option 02) and is built with multiple international hazardous area certifications (Option 05). Designed to pair with the Bently Nevada 330930 extension cable and the 330980 Proximitor sensor, this transducer system is used where standard 8 mm probes are too large, or where machinery geometries present severe counterbore restrictions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFully threaded 3\/8-24 UNF-2A body (Option 00 unthreaded length) ensuring maximum mounting flexibility.\u003c\/li\u003e\n  \u003cli\u003e3.6-inch overall case length (Option 36) providing the rigid depth required for deep-seated machine casing installations.\u003c\/li\u003e\n  \u003cli\u003e0.5-meter (20-inch) total probe length (Option 05) reducing intermediate cabling slack in close-coupled installations.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector (Option 02) establishing a solid, low-noise connection with the system extension cable.\u003c\/li\u003e\n  \u003cli\u003eMultiple hazardous area approvals (Option 05) certifying the transducer for intrinsically safe and non-incendive zones.\u003c\/li\u003e\n  \u003cli\u003eHigh-stability polyphenylene sulfide (PPS) tip construction with a 3.2 mm diameter optimized for tight targets and small shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCentrifugal compressors and high-speed pumps with shaft diameters smaller than 30 mm.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbine vibration and thrust position monitoring.\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery installations where tight mechanical clearances or narrow counterbores restrict standard probe sizes.\u003c\/li\u003e\n  \u003cli\u003eAuxiliary rotating machinery requiring reliable non-contact eddy-current shaft displacement tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment A: Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment B: Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e36\u003c\/td\u003e\n      \u003ctd\u003e3.6 in (91 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment C: Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (20 inches) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment D: Connector and Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment E: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSegment F: Configuration Suffix\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eStandard multiple approvals configuration suffix\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908-00-36-05-02-05-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUnarmored (without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.6 in (91.4 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 meters (20 inches)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, FEP insulated, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-55 degC to +177 degC (-67 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (without safety barriers), -23 Vdc to -26 Vdc (with safety barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) maximum rated (probe case to lead)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (Option 05: CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSet the probe-to-target gap to 1.0 mm (40 mils) to establish the -9.0 Vdc nominal bias center point of the linear range.\u003c\/li\u003e\n  \u003cli\u003eEnsure that thread tightening torque on the 3\/8-24 UNF-2A stainless steel body is kept within recommended engineering limits to prevent threads from seizing or stripping.\u003c\/li\u003e\n  \u003cli\u003eMaintain recommended bend radiuses when routing the 75 ohm coaxial FEP-insulated probe cable; do not pinch or expose cable to high-abrasion surfaces.\u003c\/li\u003e\n  \u003cli\u003eWhen installing multiple probes, maintain a minimum tip separation of 25 mm (1.0 in) for axial position or 23 mm (0.9 in) for radial vibration to prevent electromagnetic cross-talk.\u003c\/li\u003e\n  \u003cli\u003eProtect the ClickLoc connector from machine oils and contaminants; applying a connector protector or silicone self-fusing tape (Bently catalog number 03200006) is recommended for external routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEMC Directive 2014\/30\/EU (EN 61000-6-2 and EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU and China RoHS EFUP 15 years\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT = 0) and SIL 3 (HFT = 1) capability\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga for Zone 0 installations; Ex ec\/nA IIC T5...T1 Gc for Zone 2 installations\u003c\/li\u003e\n  \u003cli\u003eNorth American (cNRTLus): Class I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga; Class I, Division 1 \u0026amp; 2, Groups A, B, C, and D\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666618872171,"sku":"330908-00-36-05-02-05-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330908-00-36-05-02-05-05-3300-nsv-proximity-probes-5hz3khsakwz_c649ab29-30c7-4369-b2d3-1187e124b09f.jpg?v=1765444230","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330908-00-36-05-02-05-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}