{"product_id":"bently-nevada-330980-50-00-3300-xl-nsv-proximitor-sensor","title":"Sensor Proximitor Bently Nevada 330980-50-00 3300 XL NSv","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330980-50-00\u003c\/strong\u003e is a non-contacting proximity sensor designed for use within the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. This sensor is engineered for machines with tight installation requirements, such as centrifugal air compressors, refrigeration compressors, and process gas compressors, where counter bore, sideview, or rearview restrictions limit the use of standard transducer systems. The \u003cstrong\u003e330980-50-00\u003c\/strong\u003e functions by outputting an Average Scale Factor of 7.87 V\/mm (200 mV\/mil), which is ideal for small target applications such as measuring radial vibration on shafts smaller than 51 mm or axial position on flat targets smaller than 15 mm.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003eProximitor Sensor\u003c\/strong\u003e features a thin design optimized for traditional panel mount configurations. It provides advanced RFI\/EMI immunity that prevents nearby high-frequency radio signals from adversely affecting the transducer system, enabling it to achieve European CE mark approvals without specialized mounting considerations. Additionally, the device is equipped with SpringLoc terminal strips that require no special installation tools, facilitating robust and fast field wiring connections.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for space-restricted industrial applications with a thin and compact panel-mount design.\u003c\/li\u003e\n\u003cli\u003eFeatures an integrated SpringLoc terminal strip to accelerate field installation and maximize wiring robustness without special tools.\u003c\/li\u003e\n\u003cli\u003eProvides high RFI\/EMI immunity to resist electromagnetic noise from nearby high-frequency radio devices.\u003c\/li\u003e\n\u003cli\u003eProtects internal transducer electronics against electrostatic discharge at the terminals and connector interfaces.\u003c\/li\u003e\n\u003cli\u003eCapable of driving direct replacements for legacy 3300 RAM and 3000-series or 7000-series 190 Transducer Systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors \u003c\/li\u003e\n\u003cli\u003eRefrigeration compressors \u003c\/li\u003e\n\u003cli\u003eProcess gas compressors \u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on small-diameter shafts \u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small flat targets \u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed, and Phase reference (Keyphasor) signal monitoring \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330980\u003c\/td\u003e\n\u003ctd\u003eNSv Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal length and mounting option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 metre (16.4 feet) system length, panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency approval option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Input\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 ohms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils), beginning at approximately 0.25 mm (10 mils) from target \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% including interchangeability error \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor Material\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003eSpringLoc terminal strips \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNet Weight (typical)\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Secure the device into the designated housing or junction box plate using the integrated panel-mount base orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect field wiring using 0.2 to 1.5 mm2 (16 to 24 AWG) conductors, or 0.25 to 0.75 mm2 (18 to 23 AWG) if using ferrules. A three-conductor shielded triad cable is recommended.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e Ensure the total distance between the Proximitor Sensor and the associated monitor does not exceed 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Prevention:\u003c\/strong\u003e While terminal and connector tracks include internal protection circuits, use an ESD wrist strap and standard grounding practices during handling and field terminal wire connections to avoid electrostatic discharge damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666846511467,"sku":"330980-50-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-50-00-nsv-proximitor-sensor-mkqkniffh3n_2c8deaf5-adf3-4ef9-88be-ef6c2eabde61.jpg?v=1765448933","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330980-50-00-3300-xl-nsv-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}