{"product_id":"bently-nevada-330980-71-00-3300-xl-nsv-proximitor-sensor","title":"Sensor Proximitor Bently Nevada 330980-71-00 3300 XL NSv","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330980-71-00\u003c\/strong\u003e is a non-contacting \u003cstrong\u003e3300 XL NSv Proximitor Sensor\u003c\/strong\u003e designed as part of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. It is specifically engineered for use with centrifugal air compressors, refrigeration compressors, process gas compressors, and other machinery exhibiting tight installation requirements or small target areas. This includes measuring radial vibration or radial position on shafts smaller than 51 mm (2 inches) and axial position on flat targets smaller than 15 mm (0.6 inches).\u003c\/p\u003e\n\u003cp\u003eThe device features an enhanced side-view profile and small target characteristics that deliver a 1.5 mm (60 mils) linear range. Utilizing SpringLoc terminal strips, it allows robust field wiring connections without requiring specialized installation tools. Its compact mechanical profile supports high-density installations while providing immunity against RFI\/EMI high-frequency radio signals.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePart of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e optimizing performance for tight installation constraints.\u003c\/li\u003e\n\u003cli\u003eCompact design allows mounting in either high-density DIN-rail installations or traditional panel mount configurations.\u003c\/li\u003e\n\u003cli\u003eIntegrates SpringLoc terminal strips to enable fast, secure field wiring without specialized installation tools.\u003c\/li\u003e\n\u003cli\u003eEnhanced RFI\/EMI immunity protects the transducer system from nearby high-frequency radio signal interference.\u003c\/li\u003e\n\u003cli\u003eDefault factory calibration to AISI 4140 steel, with alternative material calibrations available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal air compressors, refrigeration compressors, and process gas compressors.\u003c\/li\u003e\n\u003cli\u003eRadial vibration and radial position measurements on fluid-filmed bearing machines with small shafts.\u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements on small or restricted flat targets.\u003c\/li\u003e\n\u003cli\u003eTachometer, zero speed measurements, and phase reference (Keyphasor signals).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330980-71-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 meters (23.0 feet) system length, DIN mount, Agency Approval: Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts one non-contacting 3300 RAM or 3300 NSv Proximity Probe and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption (-23 Vdc to -26 Vdc with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over the 1.5 mm linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils) starting at approx. 0.25 mm (10 mils) from target (0.25 to 1.75 mm \/ 10 to 70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than plus\/minus 0.06 mm (plus\/minus 2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 (18 to 23 AWG) with ferrules]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Field Wiring Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet) between Proximitor Sensor and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA380 aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Sensor Weight (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 g (9 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are protected (Tested to IEC 68-2-3 damp heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Designed for 35mm DIN rail mounting installations. Ensure a minimum additional clearance of 3.05 mm (0.120 inches) is available to remove the DIN rail smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use a three-conductor shielded triad cable between the sensor and the monitor up to a maximum length of 305 meters (1000 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge:\u003c\/strong\u003e Take reasonable engineering precautions to avoid electrostatic discharge during handling and electrical connection hookup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Ensure the proper mounting pads are utilized to isolate the sensor body from the housing ground environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions) for Industrial Environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 (HFT = 0), SIL 3 (HFT = 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e 2019 Rules for Conditions of Classification (Part 1, 1-1-1\/7.7, 1-1-A3, 1-1-A4) and Part 1 Offshore Units and Structures (1-1-4\/9.7, 1-1-A2, 1-1-A3).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848969067,"sku":"330980-71-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330980-71-00-nsv-proximitor-sensor-ve42ucabr4j_6166de64-f722-486c-802a-f17976637fcc.jpg?v=1765449002","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-330980-71-00-3300-xl-nsv-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}