{"product_id":"bently-nevada-3500-22-01-01-01-3500-series-transient-data-interface","title":"Bently Nevada 3500\/22-01-01-01 3500 Series Transient Data Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Managing the primary communication link between Bently Nevada 3500 machinery protection systems and supervisory host software, the \u003cstrong\u003eBently Nevada 3500\/22-01-01-01\u003c\/strong\u003e functions as the vital \u003cstrong\u003eTransient Data Interface\u003c\/strong\u003e (TDI) module. This unit collects critical static and transient dynamic data from the rack's monitor modules and transmits it to System 1 condition monitoring software over high-speed networks. Engineered for high reliability, it integrates seamlessly into industrial control environments to support real-time diagnostics and machine health analysis.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eContinuous collection of static and transient dynamic data (waveforms) for diagnostic software.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-speed 10Base-T\/100Base-TX Ethernet connection for real-time plant network interfacing.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eDual-port communications enabling integration with both configuration and data acquisition systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eStandard TDI configuration designed for conventional machinery monitoring and asset protection applications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eOnboard diagnostics and self-test capabilities to ensure constant operational integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eSteam and gas turbine vibration monitoring networks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCentrifugal and reciprocating compressor diagnostic setups.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCritical asset condition monitoring via System 1 software platforms.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eModbus TCP\/IP industrial network integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold;\"\u003eOption Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003e3500\/22-01\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eStandard Transient Data Interface Type\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e10Base-T\/100Base-TX Ethernet I\/O Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eCSA\/NRTL\/C Agency Approval Option (Class I, Div 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e3500\/22-01-01-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eTransient Data Interface (TDI)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eEthernet Port Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e10Base-T \/ 100Base-TX Auto-Negotiation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSupported Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eProprietary Bently Nevada protocol, Modbus TCP\/IP (optional configuration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e-30 to +65 degC (-22 to +150 Fahrenheit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e-40 to +85 degC (-40 to +185 Fahrenheit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eHumidity Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e95% non-condensing relative humidity\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eTDI Module Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eI\/O Module Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e3.00 kg (6.6 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eUnited States of America\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold; width: 30%;\"\u003ePort \/ Connector\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003ePrimary RJ-45\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eEthernet connection to the host computer \/ System 1 server\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003eConfig Port (Front)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eUSB or Serial communication port for direct local laptop configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e\u003cstrong\u003eTDI Backplane Pinout\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eContinuous rack communication bus and monitor module data transfer\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The 3500\/22 TDI is the modern replacement for the legacy 3500\/20 Rack Interface Module (RIM). Note that upgrading from a 3500\/20 to a 3500\/22 requires updating the 3500 rack configuration software. Be aware that firmware dependencies may exist across older channel monitor modules (like the 3500\/42M) when deploying the TDI; verify that monitor module firmware versions align with the TDI firmware release.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When running high-density transient acquisition on multiple channels, ensure that your network bandwidth is sufficiently provisioned. The TDI prioritizes machinery protection functions on the backplane, but a congested Ethernet network can cause delays in dynamic waveform transfers to System 1. Ensure the 3500\/22 is installed in the slot immediately adjacent to the power supplies (typically slot 1) as specified by the backplane design.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always use high-quality shielded twisted-pair (STP) cabling for the Ethernet interface to protect against electromagnetic interference (EMI) generated by surrounding heavy rotating machinery. For initial IP address configuration, connect directly to the front-panel configuration utility port before mounting the module in a remote rack location.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: ELECTRICAL \u0026amp; PROTECTION HAZARD\u003c\/strong\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003e\n    Before installing or removing the 3500\/22 module or its corresponding I\/O module, completely de-energize the entire 3500 rack. Failure to isolate the power supplies can cause electrical arcing, potential module damage, or unintended trips of connected machinery protection relays.\n  \u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eEnsure the power supplies for the 3500 rack are switched off and isolated.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInsert the 3500\/22 TDI Module into the correct slot (leftmost position, adjacent to the power supply).\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInstall the 10Base-T\/100Base-TX Ethernet I\/O module into the corresponding slot at the rear of the rack.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSecure all panel fasteners and plug in the shielded RJ-45 Ethernet network connection before powering the system back up.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668278014315,"sku":"3500\/22-01-01-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-22-01-01-01-yzy5ikm3o50_78e7d847-a404-4806-bcaa-7849716bc856.jpg?v=1765520316","url":"https:\/\/www.plcprotech.com\/id\/products\/bently-nevada-3500-22-01-01-01-3500-series-transient-data-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}