{"product_id":"danfoss-132l6121-ic2-30fa3n04-09a0e20f4-acbc-frequency-converter","title":"Danfoss 132L6121 IC2-30FA3N04-09A0E20F4+ACBC Konverter Frekuensi","description":"\u003cp\u003eThe \u003cstrong\u003eDanfoss 132L6121\u003c\/strong\u003e is a high-performance \u003cstrong\u003eiC2-30 Frequency Converter\u003c\/strong\u003e, specifically engineered for efficient motor control in a wide range of industrial applications. As part of the \u003cstrong\u003eiC2-30\u003c\/strong\u003e series, this \u003cstrong\u003eair-cooled\u003c\/strong\u003e unit provides reliable variable speed control for three-phase induction motors, optimizing energy consumption and process precision.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Optimized for space-saving installations in control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Brake Chopper:\u003c\/strong\u003e Includes a built-in brake chopper (+ACBC) for applications requiring dynamic deceleration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Performance:\u003c\/strong\u003e Rated for 4 kW output with a 9.0 A nominal current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Connectivity:\u003c\/strong\u003e Designed for 380-480 V AC three-phase mains supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Features C4 EMC category filtering for industrial network environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC fan and pump systems\u003c\/li\u003e\n\u003cli\u003eConveyor belts and material handling\u003c\/li\u003e\n\u003cli\u003ePackaging machinery\u003c\/li\u003e\n\u003cli\u003eCentrifugal pumps\u003c\/li\u003e\n\u003cli\u003eTextile machinery and general-purpose automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eiC2-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e132L6121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecification Key\u003c\/td\u003e\n\u003ctd\u003eIC2-30FA3N04-09A0E20F4+ACBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e9.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Voltage\u003c\/td\u003e\n\u003ctd\u003e380-480 V AC (Three-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eAir Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Category\u003c\/td\u003e\n\u003ctd\u003eC4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake Chopper\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The unit is designed for vertical mounting in a clean, dry, and well-ventilated enclosure. Ensure adequate clearance above and below the drive to facilitate airflow for the air-cooling system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditions:\u003c\/strong\u003e Maintain ambient temperatures within the manufacturer's specified limits to prevent thermal derating. Avoid environments with excessive dust, corrosive gases, or high humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Proper grounding of the frequency converter chassis is critical to ensure EMC compliance and operator safety. Use a low-impedance ground connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Separate power cables from control and signal cables to minimize electromagnetic interference (EMI). Use shielded cables for motor connections, ensuring the shield is properly terminated at both the drive and motor ends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrake Connection:\u003c\/strong\u003e If utilizing the integrated brake chopper, ensure the external braking resistor is sized correctly for the application's duty cycle and peak power requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102306263403,"sku":"132L6121","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132l6121-lxd1na4d2kw.png?v=1776137050","url":"https:\/\/www.plcprotech.com\/id\/products\/danfoss-132l6121-ic2-30fa3n04-09a0e20f4-acbc-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}