{"product_id":"emerson-deltav-ve3008-kj2005x1-mq1-12p6381x032-mq-controller","title":"Emerson DeltaV VE3008 KJ2005X1-MQ1 12P6381X032 MQ Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE3008\u003c\/strong\u003e is an \u003cstrong\u003eMQ Controller\u003c\/strong\u003e designed for the DeltaV Distributed Control System (DCS). This hardware component provides communication and control between field devices and other nodes on the control network. It executes local control strategies with execution speeds up to every 100 ms. The \u003cstrong\u003eVE3008\u003c\/strong\u003e offers identical configurable memory and execution capabilities to the legacy MD Plus Controller, supporting seamless system scalability and legacy migrations. Online operational updates are automatically captured to ensure data integrity within the plant architecture.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeamlessly executes control strategies with configurable update loops as fast as 100 ms.\u003c\/li\u003e\n\u003cli\u003eRetains entire active control strategies within internal non-volatile random-access memory (NVM RAM) to enable completely autonomous cold restarts following a supply power loss.\u003c\/li\u003e\n\u003cli\u003eIntegrates full-duplex Ethernet communication ports capable of reaching up to 100 MB\/s maximum throughput.\u003c\/li\u003e\n\u003cli\u003ePerforms automated system identification and network addressing immediately upon initial system power-up.\u003c\/li\u003e\n\u003cli\u003eDetects physical subsystem I\/O interfaces automatically to identify distinct connected channel attributes.\u003c\/li\u003e\n\u003cli\u003eBuilt-in visual identification function allows operators to flash specific faceplate LEDs via user interface software commands.\u003c\/li\u003e\n\u003cli\u003eFacilitates data pass-through capabilities to securely route smart HART device variables directly to engineering workstations.\u003c\/li\u003e\n\u003cli\u003eProvides functional compatibility for assignments to CHARM I\/O Cards (CIOC) for electronic marshalling schemes when operating on supported software environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChemical processing facilities and distillation column control networks.\u003c\/li\u003e\n\u003cli\u003ePower generation utility oversight and distributed node monitoring.\u003c\/li\u003e\n\u003cli\u003eContinuous batch execution and process loop regulations in oil and gas refineries.\u003c\/li\u003e\n\u003cli\u003eLegacy automation platform migrations including PROVOX and RS3 structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMQ Controller\u003c\/td\u003e\n\u003ctd\u003eVE3008 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Module Hold-down Screw; box of 20\u003c\/td\u003e\n\u003ctd\u003eKJ4010X1-BP3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMQ Controller \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Assembly \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKJ2005X1-MQ1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Layout Print Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12P6381X022 REV B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in Malaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Memory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 MB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Signal Tag (DST) Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 to 750 DSTs \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Source Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplied by System Power Supply through 2-wide Power\/Controller Carrier \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 W typical, 7.0 W maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Overcurrent Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 A, non-replaceable fuses \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Network Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-pin RJ-45 connector \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Network Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-pin RJ-45 connector \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.18 cm (1.65 in.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.91 cm (5.48 in.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.06 cm (6.32 in.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC (-40 to 158 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Gaseous Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 g 2-sine wave for 11 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Vibration Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak from 5 Hz to 16 Hz; 0.5 g from 16 Hz to 150 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eLED Indicator Status\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Meaning\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGreen - Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates DC power is applied \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRed - Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates an error condition \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGreen - Active\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates that the controller is operating as the primary controller \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGreen - Standby\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates that the controller is operating as a backup controller (reserved for future use) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYellow Flashing - Pri. CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates valid primary control network communication \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYellow Flashing - Sec. CN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates valid secondary control network communication \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAll except Power flashing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVisual identification of controller initiated from user interface software by ping command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAll except Power flashing, alternating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade in progress \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Mounting:\u003c\/strong\u003e The module must be positioned and installed securely on the right slot of a compatible M-series Power\/Controller Carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Provision:\u003c\/strong\u003e Each controller node demands an independent, dedicated system power supply unit tied to the carrier backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Version Dependencies:\u003c\/strong\u003e Baseline operation requires DeltaV software version v10.3.1 or higher. Electronic marshalling or CHARM structural allocation necessitates software version v14.3 or later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Isolation:\u003c\/strong\u003e For implementations utilizing Electronic Marshalling, dedicated DeltaV Smart Switches must be installed to bridge data paths between controllers and CHARM I\/O Cards (CIOC).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Compliance:\u003c\/strong\u003e Certified \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61326-1 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM Certification (USA):\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D, T4 hazardous locations \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecFM Certification (Canada):\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D, T4 hazardous locations \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Classification:\u003c\/strong\u003e II 3G Ex ec IIC T4 Gc (Zone 2 installation environments) \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Ex Classification:\u003c\/strong\u003e II 3G Ex ec IIC T4 Gc \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Appraisals:\u003c\/strong\u003e Compliant with IACS E10 guidelines; holds ABS Certificate of Design Assessment and DNV Type Approval Certificate \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Cybersecurity:\u003c\/strong\u003e Certified to Achilles Communications Certification Level 2 requirements \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695182213483,"sku":"VE3008 KJ2005X1-MQ1 12P6381X032","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-ve3008-kj2005x1-mq1-12p6381x032-deltav-plc-module-hugel1ep1eq_57aa62e0-4469-4445-9992-a51d2f02ea9f.jpg?v=1766114332","url":"https:\/\/www.plcprotech.com\/id\/products\/emerson-deltav-ve3008-kj2005x1-mq1-12p6381x032-mq-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}