{"product_id":"general-electric-is220pscah1a-mark-vie-serial-communication-i-o-pack","title":"General Electric IS220PSCAH1A Mark VIe Paket Komunikasi Serial I\/O  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PSCAH1A\u003c\/strong\u003e is a specialized serial communication I\/O pack developed for the Mark VIe control system. This module functions as a critical communication interface designed to collect and distribute data between field serial links and the broader industrial network infrastructure. Engineered for deployment in diverse control architectures, the \u003cstrong\u003eIS220PSCAH1A\u003c\/strong\u003e provides precise signal coordination and data passing required for demanding industrial automation setups, ensuring system synchronization and continuous diagnostics reporting within hazardous operating conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual Ethernet ports providing redundant network interfaces for stable communication links\u003c\/li\u003e\n\u003cli\u003eEmbedded internal hardware diagnostic and fault monitoring utilities\u003c\/li\u003e\n\u003cli\u003eDedicated configuration support tailored for Mark VIe distributed system layouts\u003c\/li\u003e\n\u003cli\u003eRobust design capable of continuous operation in high-reliability applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine control system communication links\u003c\/li\u003e\n\u003cli\u003eDistributed control system data gathering\u003c\/li\u003e\n\u003cli\u003eSubstation or industrial plant automation\u003c\/li\u003e\n\u003cli\u003ePower generation management networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PSCAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSerial Communication I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient Temperature Rating\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 degC (-22 to +149 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the installation site matches the environmental rating of -30 to +65 degC before mounting.\u003c\/li\u003e\n\u003cli\u003eSecurely mount the I\/O pack onto its matching industrial terminal board structure.\u003c\/li\u003e\n\u003cli\u003eAttach all redundant Ethernet connection lines firmly to preserve constant controller feedback pathways.\u003c\/li\u003e\n\u003cli\u003eFollow explicit plant instructions regarding grounding and shielding practices to counteract electrical noise or interference.\u003c\/li\u003e\n\u003cli\u003eExercise proper technical handling procedures during assembly in classified hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Div 2, Groups A, B, C, D, T4\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 2, AEx nA IIC T4, Ex nA IIC T4 GcX\u003c\/li\u003e\n\u003cli\u003eUL508 Ed.17\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No.142-M1987\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA-12.12.01-2015\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA-C22.2 No.213-15\u003c\/li\u003e\n\u003cli\u003eUL60079-0 Ed.5\u003c\/li\u003e\n\u003cli\u003eUL60079-15 Ed.3\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA-C22.2 No.60079-0:11\u003c\/li\u003e\n\u003cli\u003eCAN\/CSA-C22.2 No.60079-15:12\u003c\/li\u003e\n\u003cli\u003eEN60079-0:2012\u003c\/li\u003e\n\u003cli\u003eEN60079-15:2010\u003c\/li\u003e\n\u003cli\u003eEx nA IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003eUL E207685\u003c\/li\u003e\n\u003cli\u003eUL DEMKO 12 ATEX 1114875X\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695412736363,"sku":"IS220PSCAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220pscah1a-communications-module-ngjedsa3mkw_41ee23d8-0b8f-4e4d-a5d5-25bd3c205970.jpg?v=1766135122","url":"https:\/\/www.plcprotech.com\/id\/products\/general-electric-is220pscah1a-mark-vie-serial-communication-i-o-pack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}