{"product_id":"honeywell-tc-fpcxx2-experion-series-power-supply-module","title":"Honeywell TC-FPCXX2 Experion Series Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding regulated operating power to local rack configurations, the \u003cstrong\u003eHoneywell TC-FPCXX2\u003c\/strong\u003e serves as a high-reliability chassis power supply module engineered for industrial process control environments. This module accepts selectable AC input ranges to deliver a maximum continuous output of \u003cstrong\u003e70 W at 60 degC\u003c\/strong\u003e, ensuring stable voltage distribution to adjacent controller and I\/O modules. The unit incorporates integrated thermal protection and structural overcurrent safeguarding via an onboard soldered internal fuse to maintain system integrity under transient fault conditions.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Range Input:\u003c\/strong\u003e Field-selectable slide switch accommodates both 85-132 VAC and 170-265 VAC nominal input voltages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal De-rating Performance:\u003c\/strong\u003e Capable of delivering a full 70 W power envelope at ambient temperatures up to 60 degC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Fault Isolation:\u003c\/strong\u003e Features a factory-soldered, non-replaceable internal input fuse to protect upstream distribution systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForm Factor Integration:\u003c\/strong\u003e Standard chassis slot footprint allows direct insertion into compatible Honeywell controller backplanes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eHoneywell Experion LX control systems and regional I\/O rack power distribution.\u003c\/li\u003e\n  \u003cli\u003eLegacy PlantScape controller chassis retrofits and upgrades.\u003c\/li\u003e\n  \u003cli\u003eDistributed Control System (DCS) nodes in petrochemical, refining, and water treatment utilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Reference\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTC-FPCXX2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85-132 VAC or 170-265 VAC (User-selectable via slide switch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eLine Frequency Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e47-63 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMaximum Output Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e70 W at 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOvercurrent Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNon-replaceable soldered-in input fuse\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModule Dimensions (W x D x H)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e11.2 cm x 14.5 cm x 14.0 cm (4.41 in x 5.71 in x 5.51 in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Module Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.1 kg (2.43 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.1 kg (4.63 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe TC-FPCXX2 is functionally interchangeable with older Honeywell legacy chassis power options, but caution must be exercised regarding mounting pitch and backplane connector alignment. While standard C200 controllers utilize similar configurations, always verify that the chassis slot keying matches the deep-recessed connector housing on the back of this module before attempting hot insertion.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this power supply uses a non-replaceable, soldered-in input fuse, external overcurrent protection (such as an inline terminal block fuse or miniature circuit breaker rated at 5 A or 10 A depending on input configuration) is highly recommended. If an internal component fault triggers the soldered fuse, the entire unit must be serviced or replaced; external fusing mitigates transient line surges from rendering the module permanently inoperable on site.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBefore applying power, verify the position of the dual-voltage slide selector switch located on the unit. Energizing a module configured for 115 VAC with a 230 VAC supply line will cause immediate, catastrophic damage to the input varistors and internal circuitry, voiding standard field warranties.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all incoming AC power lines before mounting or sliding the power module into the chassis. Do not touch terminal screws or the rear connector interface while the main bus is energized. Failure to comply can result in severe electrical shock, equipment destruction, or unexpected process downtime.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eLocate the input voltage selector switch on the side or rear of the module. Confirm its setting matches your local utility supply level (115 VAC or 230 VAC nominal).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the module with the guide rails of the designated left-most power supply slot in the chassis.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the module firmly backward until the rear interface connector seats fully into the backplane socket. Hand-tighten the integrated retaining screws to secure the unit structurally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the external, de-energized AC supply wiring to the input terminals, ensuring the protective earth ground wire is established first.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705311129963,"sku":"TC-FPCXX2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TC-FPCXX2-taqlrr1k2hu_93d3bae9-6b7c-4785-beb4-e2a2eb4db4e0.jpg?v=1766639510","url":"https:\/\/www.plcprotech.com\/id\/products\/honeywell-tc-fpcxx2-experion-series-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}