{"product_id":"mitsubishi-electric-fr-a840-132k-1-fr-a800-variable-frequency-drive","title":"Mitsubishi Electric FR-A840-132K-1 FR-A800 Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-capacity heavy industrial applications, the \u003cstrong\u003eFR-A840-132K-1\u003c\/strong\u003e variable frequency drive delivers precise motor speed and torque control within the Mitsubishi Electric FR-A800 series portfolio. This high-performance inverter features advanced vector control algorithms and a dedicated FM (frequency monitor) pulse train output terminal to optimize energy efficiency and system feedback across diverse motor topologies, including standard induction and permanent magnet synchronous motors.\u003c\/p\u003e\n\n\u003cp\u003eSupporting three-phase 380 V to 500 V input distributions, this drive provides a continuous rated output current of 260 A, driving motors up to 132 kW. Standard integration incorporates built-in RS-485, RS-422, and RS-232 serial interfaces to facilitate rapid interfacing with programmable logic controllers (PLCs) and distributed control systems (DCS). Its robust cooling structure and protective design are optimized for reliable continuous operation in harsh manufacturing environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAdvanced Real-Time Sensorless Vector Control and PM sensorless vector control for exceptional speed accuracy.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in safety stop function compliant with EN ISO 13849-1 Category 3\/PLd for safe torque off (STO) safety integration.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PLC function allowing localized user program execution and custom logic control without an external processor.\u003c\/li\u003e\n  \u003cli\u003eFM type terminal configuration supplying high-speed pulse train output for analog tracking and system monitoring.\u003c\/li\u003e\n  \u003cli\u003eExceptional overload tolerance designed to withstand harsh transient load spikes during starting and stopping sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty municipal and industrial pumping stations.\u003c\/li\u003e\n  \u003cli\u003eHigh-inertia ventilation fans, industrial blowers, and HVAC air handlers.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems, automated material handling, and heavy hoisting machinery.\u003c\/li\u003e\n  \u003cli\u003eIndustrial mixers, extruders, crushers, and centrifuges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFR-A840-132K-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFR-A800\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Motor Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e132 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e260 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Output Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e198 kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase, 380 V to 500 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase, 380 V to 500 V AC (50\/60 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRS-485, RS-422, RS-232 (built-in Modbus-RTU)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFM type (pulse train monitor output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e740 mm x 465 mm x 360 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e79 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount vertically on a flat, non-combustible surface inside an IP2x or IP54 industrial control cabinet to prevent ingress of conductive dust or corrosive gases.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e Maintain a minimum space of 100 mm at the top and bottom of the drive frame to ensure unhindered exhaust airflow from the internal cooling fans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the ground terminal directly to a dedicated system earth point. Ensure the grounding resistance is 10 ohms or less to limit noise and ensure electrical safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e Utilize high-frequency braided shielded motor power cables, grounding the shield on both the drive plate and the motor frame to minimize electromagnetic radiation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark (Low Voltage Directive \/ EMC Directive)\u003c\/li\u003e\n  \u003cli\u003eUL Listed (US and Canada)\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102134264171,"sku":"FR-A840-132K-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fr-a840-132k-1-5hotp1s2qel.png?v=1776137464","url":"https:\/\/www.plcprotech.com\/id\/products\/mitsubishi-electric-fr-a840-132k-1-fr-a800-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}