{"product_id":"mitsubishi-electric-fx2n-16mr-ds-fx2n-series-base-unit","title":"Mitsubishi Electric FX2N-16MR-DS FX2N Series Base Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrated control and high-speed processing define the \u003cstrong\u003eFX2N-16MR-DS\u003c\/strong\u003e, a compact base unit belonging to the renowned FX2N series of programmable logic controllers. Engineered for robust execution in heavy-duty environments, this controller features 8 digital inputs and 8 relay outputs, managed within a space-saving chassis. Operating on a 24V DC power supply, it offers an efficient architecture for localized machine automation and decentralized control tasks. The unit serves as the processing foundation, allowing seamless integration with auxiliary expansion blocks and specialized communication modules to scale overall system capacity as needed.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEquipped with 8 digital inputs (24V DC, sink\/source selectable) and 8 relay outputs for versatile load switching.\u003c\/li\u003e\n  \u003cli\u003ePowered via 24V DC, suitable for mobile applications, control panels, and field-mounted enclosures.\u003c\/li\u003e\n  \u003cli\u003eExpandable bus connection allows the integration of additional digital, analog, and communication expansion blocks.\u003c\/li\u003e\n  \u003cli\u003eIntegrated run\/stop switch on the front panel for simplified testing and local maintenance.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed processing capability suitable for real-time logic execution, sequencing, and timing tasks.\u003c\/li\u003e\n  \u003cli\u003eRemovable terminal blocks facilitate direct, secure wiring and rapid module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePumping stations and automated water treatment systems.\u003c\/li\u003e\n  \u003cli\u003eConveyor networks, sorting systems, and material handling lines.\u003c\/li\u003e\n  \u003cli\u003eHVAC control systems and building automation distribution panels.\u003c\/li\u003e\n  \u003cli\u003ePackaging, labeling, and small-scale assembly machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eParameter\u003c\/strong\u003e\n      \u003cstrong\u003eSpecification\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eFX2N-16MR-DS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003eFX2N Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePLC Base Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd\u003e24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAllowable Power Range\u003c\/td\u003e\n      \u003ctd\u003e20.4V DC to 26.4V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Integrated Inputs\u003c\/td\u003e\n      \u003ctd\u003e8 Inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Type\u003c\/td\u003e\n      \u003ctd\u003e24V DC (Sink \/ Source)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Integrated Outputs\u003c\/td\u003e\n      \u003ctd\u003e8 Outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Type\u003c\/td\u003e\n      \u003ctd\u003eRelay\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Switching Voltage\u003c\/td\u003e\n      \u003ctd\u003e250V AC \/ 30V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003eApprox. 10 ms (Relay response)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003e35mm DIN Rail or Direct Screw Mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-20 to 70 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTerminal Label\u003c\/strong\u003e\n      \u003cstrong\u003eFunction \/ Assignment\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e24V \/ 0V\u003c\/td\u003e\n      \u003ctd\u003e24V DC Power Input Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFG\u003c\/td\u003e\n      \u003ctd\u003eFrame Ground \/ Protective Earth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eX0 - X7\u003c\/td\u003e\n      \u003ctd\u003eDC Digital Input Channels (0 to 7)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM (Inputs)\u003c\/td\u003e\n      \u003ctd\u003eCommon Terminal for Input Wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eY0 - Y7\u003c\/td\u003e\n      \u003ctd\u003eRelay Output Channels (0 to 7)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM0 - COM2\u003c\/td\u003e\n      \u003ctd\u003eCommon Terminals for Relay Output Groups\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Attach securely to a standard 35mm DIN rail or screw directly to an earthed backplane panel. Keep a minimum spacing of 50mm on all sides for passive cooling and terminal access.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the FG (Frame Ground) terminal to a dedicated, low-impedance functional ground (Class D grounding, 100 ohms or less) to minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route high-voltage AC output wires separate from low-voltage DC input and communication signal cables to avoid signal crosstalk. Use crimp terminals matching the M3 terminal screws.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102155399531,"sku":"FX2N-16MR-DS","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fx2n-16mr-ds-drbbkc4saft.png?v=1776137528","url":"https:\/\/www.plcprotech.com\/id\/products\/mitsubishi-electric-fx2n-16mr-ds-fx2n-series-base-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}